Giorgio Alfredo Spedicato

Dr. Giorgio Alfredo Spedicato

Università Milano-Bicocca, Milan, Lombardy, Italy

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 July 2022 in Progress in Orthodontics
Verified
Journal Article
Open access
PDF file
FPFederica Pellitteri
Federica Pellitteri
PAPaolo Albertini
Paolo Albertini
AVAngelica Vogrig
Angelica Vogrig
GSGiorgio Alfredo Spedicato
Giorgio Alfredo Spedicato
GSGiuseppe Siciliani
Giuseppe Siciliani
LLLuca Lombardo
Luca Lombardo
Background: The purpose of the present in vivo study was to compare the accuracy, in terms of trueness, between full-arch digital impressions of different intraoral scanning systems, using as a reference the ideality of the conventional impression technique. Methods: Polyvinyl siloxane (PVS) two-step technique impressions of 27 subjects were taken, and the stone casts were scanned using desktop scanners R500 3Shape. For each arch, in vivo scans were taken with intraoral scanners Carestream CS3600, CEREC Omnicam and Trios 3Shape. All the files were compared, superimposing them on the reference model to calculate the total 3D and 2D deviations. The efficiency of the digital and conventional workflows was evaluated by measuring the work time in minutes. Statistical analyses were performed using R software (R Core Team 2020) with a p-value < 0.05. Results: The three intraoral scanners differed from the PVS impression by differences of the order of 100–200 µm, and there was a trend of greater imprecision in the molar area in both dental arches. In comparison with PVS technique, CEREC tended to reduce the size of the impression, Trios presented the trend of greater precision, and Carestream showed minor differences the transversal distance. The areas of greatest discrepancy both in excess and in defect with respect to the PVS impression were the molar areas and incisal margins. Trios 3Shape recorded the shortest times and therefore with a more performing speed. Conclusion: The Trios 3Shape was found to be the most accurate single-tooth scanner, while the Carestream CS 3600 showed better inter-arch diameter performance compared to PVS impressions. The 3D and 2D analyses showed a trend of greater distortion of the impressions compared to the conventional one in the molar region.

7 October 2022 in Life
Verified
Journal Article
Open access
PDF file
Andrea AgugliaAndrea Aguglia
Andrea Aguglia
ANAntimo Natale
Antimo Natale
LFLaura Fusar-Poli
Laura Fusar-Poli
GGGiovanni Battista Gnecco
Giovanni Battista Gnecco
ALAlessio Lechiara
Alessio Lechiara
MAMario Amore
Mario Amore
The aim of the present study was to identify a cut-off of c-reactive protein (c-RP) potentially predictive of high-lethality suicide attempts (SA) in an inpatient psychiatric sample. After attempting suicide, subjects were admitted to the emergency ward of the IRCCS Ospedale Policlinico San Martino and later to the section of Psychiatry from 1 August 2013 to 31 July 2018. C-reactive protein was measured. The Area Under the Receiver Operating Characteristic (ROC_AUC) was used to assess the discriminative capacity of c-RP for high- vs. low-lethality SA, and a logistic regression was performed to detect the odds ratio, adjusted for age and sex. High-lethality suicide attempters were 133 (30.8%), while low-lethality suicide attempters were 299 (69.2%). The optimal cut-off threshold (and corresponding sensitivity and specificity values) for c-RP was 4.65 mg/L (68/71%). This cut-off corresponds to an AUC of 73.5%. An odds ratio of 4.70 was generated for current high-lethality SA after a logistic regression, adjusted for age and sex. Research on social and biological factors underlying the lethality of SA is crucial for a better understanding of this complex phenomenon. Identifying potential predictors of SA, especially those at high lethality, is essential to implement personalized preventive strategies.