Saša Zivko Štatkić

Dr. Saša Zivko Štatkić

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Ekonomika poljoprivrede
Verified
Journal Article
Open access
PDF file
ŽMŽarko Milkić
Žarko Milkić
AČAleksandar Čukarić
Aleksandar Čukarić
Saša Zivko ŠtatkićSaša Zivko Štatkić
Saša Zivko Štatkić
GMGoran Maksimović
Goran Maksimović
A mathematical model of a doubly-fed asynchronous generator is defined in the paper, using spatial vector theory, in relation to the reference axis associated with the stator. Expressions for characteristic quantities are derived, and operational characteristics for the torque, active and reactive power, power factor, and efficiency are plotted, from which generator operation is analysed at different rotational speeds. Based on this, possibilities and advantages of using doubly-fed asynchronous generators in wind turbines, for obtaining electrical energy from wind energy, are deduced.

1 January 2024
Verified
Conference Paper
Closed access
JVJovan Vukasinovic
Jovan Vukasinovic
NMNebojsa Mitrovic
Nebojsa Mitrovic
Saša Zivko ŠtatkićSaša Zivko Štatkić
Saša Zivko Štatkić
BBBojan Banković
Bojan Banković
FFFilip Filipović
Filip Filipović
In this paper, experimental verification of the numerical optimization method two-stage PSO algorithm (TSPSO) for parameter identification of a cage induction motor using nominal motor data related to direct grid supply was performed. The TSPSO algorithm consists of two stages: the first stage estimates parameters for the rated operating mode, while the second stage estimates rotor parameters during motor startup. The TSPSO algorithm indirectly applies an approximation of the rotor parameter change as a function of speed to consider the influence of the skin effect at motor start-up and achieves the connection between the two stages. For the proper operation of control algorithms in frequency converters, knowledge of the parameters of the induction motor is necessary. Regulated electric drives use induction motors and frequency converters from various manufacturers. For this reason, different procedures for motor parameter identification are applied, which are integrated into the frequency converters. In this study, an experimental method was used for parameter identification of the cage induction motor based on the application of an offline procedure in a frequency converter for the identification of parameters of the cage induction motor in a standstill state. In this paper, independent parameter identification of the cage induction motor with the same nominal data was performed using two different methods. The results obtained show a certain level of agreement in the parameter values of the equivalent circuit, thereby experimentally verifying the numerical TSPSO algorithm.

27 February 2026 in Energies
Verified
Journal Article
Open access
PDF file
IJIlija Borislav Jeftenic
Ilija Borislav Jeftenic
Saša Zivko ŠtatkićSaša Zivko Štatkić
Saša Zivko Štatkić
SASnezana Aleksandrovic
Snezana Aleksandrovic
NMNebojsa Mitrovic
Nebojsa Mitrovic
This paper presents a signal-processing methodology for assessing thermal stress and fatigue damage in IGBT modules. This study utilizes junction temperature data from operational frequency converters at a belt conveyor station rather than conventional approaches. These in situ measurements ensure that thermal profiles accurately reflect actual loading conditions. A reliability framework based on mission profiles assesses the contribution of each operational regime. We examine transient overloads, steady-state operation, and periods of low load specifically. We apply Miner’s rule and rainflow counts to the analyzed temperature profiles. This enables the assessment of accumulated damage in each operational segment. The primary finding indicates that a minimal duration of operational time constitutes the majority of total lifetime utilization. This disproportionate impact is attributable to transient overloads. This study quantitatively evaluates this phenomenon using Rainflow analysis to disaggregate mission profiles. The proposed framework enhances the precision of reliability engineering. It provides a valuable foundation for enhancing maintenance planning and control strategies in practical scenarios.

1 January 2024
Verified
Conference Paper
Closed access
NMNebojsa Mitrovic
Nebojsa Mitrovic
FFFilip Filipović
Filip Filipović
BBBojan Banković
Bojan Banković
VKVojkan Kostić
Vojkan Kostić
Saša Zivko ŠtatkićSaša Zivko Štatkić
Saša Zivko Štatkić
JVJovan Vukasinovic
Jovan Vukasinovic
Motor parameters are crucial for the efficient implementation of modern control algorithms, particularly for vector-controlled drives. Consequently, nearly all manufacturers of frequency converters provide the option for automatic determination of motor parameters. In the case of scalar control methods, this algorithm is relatively simple, focusing on the determination of the resistance and stator inductance of the induction motor. In contrast, vector control methods require the identification of all parameters of the equivalent circuit. Typically, the self-commissioning function is activated, allowing the converter to autonomously determine the motor parameters according to the manufacturer’s defined algorithm. This paper analyzes the identification methods used by three renowned manufacturers of frequency converters. The results obtained were compared, revealing significant differences in parameter values. Based on laboratory measurements conducted under identical conditions for all three converters, parameters were identified through no-load and short-circuit experiments at various frequencies. Numerous experiments yielded frequency-dependent parameter relationships, which were then compared with results from the self-commissioning tests. The findings elucidate the reasons for the observed discrepancies and indicate that the accuracy of the self-commissioning algorithm may be questionable.

11 April 2025 in Energies
Verified
Journal Article
Open access
PDF file
JVJovan Vukasinovic
Jovan Vukasinovic
Saša Zivko ŠtatkićSaša Zivko Štatkić
Saša Zivko Štatkić
NANebojsa Arsic
Nebojsa Arsic
NMNebojsa Mitrovic
Nebojsa Mitrovic
BPBojan Perovic
Bojan Perovic
AJAndrijana Jovanovic
Andrijana Jovanovic
This paper analyzes errors in the estimation of induction-motor-equivalent circuit parameters using an improved combined two-stage Particle Swarm Optimization (PSO) method. The proposed method accounts for variations in rotor parameters based on both linear and square root speed approximations, as well as two different approaches for the stator and rotor leakage reactance ratios. The first approach assumes that the starting rotor leakage reactance is equal to the stator leakage reactance, while the second considers them as distinct. Improvement of the algorithm consists of increasing the accuracy of the approximations of parameter changes on the rotor. Thanks to more accurate determination of the initial rotor parameters, both approximations provide better results in parameter estimation. The analysis involved sixteen induction motors with four different power ratings and four different pole numbers. The analysis aimed to assess the impact of these approximations and assumptions on equivalent circuit parameter estimation errors. The estimated torque-speed characteristics closely matched the manufacturer’s reference data, including starting, maximum, and full-load torques. The deviation of the estimated torque-speed characteristics from the reference characteristics, within a defined speed range, is defined as the mean absolute percentage error. Based on the obtained results, the mean absolute percentage error is complex and depends on rotor parameter speed approximations, stator and rotor leakage reactance ratios, and the full power of the induction motor.

1 January 2025 in Energija Ekonomija Ekologija
Verified
Journal Article
Closed access
NDNovi Beograd EuroTeleSities d.O.O
Novi Beograd EuroTeleSities d.O.O
SMSamed Mušović
Samed Mušović
Saša Zivko ŠtatkićSaša Zivko Štatkić
Saša Zivko Štatkić
KMKosovska Mitrovica Fakultet Tehničkih Nauka U Kosovskoj Mitrovici
Kosovska Mitrovica Fakultet Tehničkih Nauka U Kosovskoj Mitrovici
Željko V DespotovićŽeljko V Despotović
Željko V Despotović
UPUniverzitet U Beogradu Institut Mihajlo Pupin
Univerzitet U Beogradu Institut Mihajlo Pupin
The paper presents the concept of the radio base station system, their function as well as the topology of the solar power supply. The paper provides a more detailed description of the implementation of solar power plants on radio base stations as well as some design methods related to special power installations such as the solar power supply shown in this paper. All the advantages and disadvantages of the project of building solar power plants on radio base stations are listed and practical technical solutions for maintaining electrical installations in the power supply system, which are part of everyday practice, are presented. At the end of the paper, the results of the design and realisation of the solar power supply with an output power of 8kW at the "Kumane" radio base station were given.