Stefan Vandeweghe

Prof. Stefan Vandeweghe

Ghent University

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2016 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
SVStefan Vandeweghe
Stefan Vandeweghe
VVValentin Vervack
Valentin Vervack
MDMelissa Dierens
Melissa Dierens
HBHugo De Bruyn
Hugo De Bruyn

10 May 2013 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
SVStefan Vandeweghe
Stefan Vandeweghe
PCPaulo G. Coelho
Paulo G. Coelho
CVChristian Vanhove
Christian Vanhove
AWAnn Wennerberg
Ann Wennerberg
RJRyo Jimbo
Ryo Jimbo

25 January 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
RDRani D'haese
Rani D'haese
TVTom Vrombaut
Tom Vrombaut
HRHERMAN JULES JOS ROEYKENS
HERMAN JULES JOS ROEYKENS
SVStefan Vandeweghe
Stefan Vandeweghe
The aim of this study was to evaluate the accuracy of full-arch digital impressions when compared to conventional impressions, when performed on the abutment or implant level. Methods: One resin cast with six implants and another cast with six abutments were scanned with Primescan v5.1 (PS51), Primescan v5.2 (PS52), Trios 3 (T3), and Trios 4 (T4). Additionally, conventional impressions (A) were made, poured in gypsum, and digitized using a lab scanner (IScan D104i). A coordinate machine (Atos, GOM, Braunschweig, Germany) was used to generate the reference scan of both casts. For all scans, the position of the implants was calculated and matched with the reference scan. Angular and coronal measurements per implant were considered for trueness and precision. Results: For the implant-level model, PS52 performed significantly better in terms of trueness and precision compared to all other impressions, except for the angular trueness of A (p = 0.072) and the coronal trueness of PS51 (p = 1.000). For the abutment-level model, PS52 also performed significantly better than all other impressions, except for the coronal trueness and precision of A (p = 1.000). Conclusions: Digital impressions for full-arch implant supported prostheses can be as accurate as conventional impressions, depending on the intra-oral scanner and software. Overall, abutment level impressions were more accurate compared to implant level impressions.


22 August 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Cristian Abad-CoronelCristian Abad-Coronel
Cristian Abad-Coronel
SVStefan Vandeweghe
Stefan Vandeweghe
MCMaría Dolores Vela Cervantes
María Dolores Vela Cervantes
MLMaría José Tobar Lara
María José Tobar Lara
NCNancy Mena Córdova
Nancy Mena Córdova
PAPaulina Aliaga
Paulina Aliaga
Dental implant placement is crucial in oral rehabilitation, requiring precision for successful outcomes. Digital technologies, including surgical guides, enhance predictability and efficiency in implant procedures. However, their impact on implant positioning accuracy is still under investigation. This systematic review aimed to evaluate the literature on implant accuracy using digital prosthetically-derived surgical guides. Registered in PROSPERO (CRD 42023483194), the review employed a PICO strategy and searched PubMed for English-language, in vivo studies from 2013 to 2023 on restrictive digital prosthetically-derived surgical guides. Two reviewers independently assessed records, with a third verifying the decisions. PRISMA guidelines were followed, yielding 24 results after excluding nine duplicates. Ten studies met the criteria after title, abstract, and keyword review, with three included after verification. These studies showed coronal deviations of 0.44 mm to 0.56 mm, apical deviations of 0.64 mm to 1.03 mm, angular deviations of 2.03° to 2.42°, and vertical deviations of 0.19 mm to 0.45 mm. Superior accuracy was noted with static guided techniques, while bilateral guides offered stability and printed guides were cost-effective. A surgical guide that comes from a planning with a primary wax-up of the prosthesis leads to the placement of a dental implant that can be functionally and esthetically rehabilitated. Further research is needed to standardize outcomes and improve implant protocols and patient outcomes.

20 January 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
RDRani D'haese
Rani D'haese
TVTom Vrombaut
Tom Vrombaut
GHGeert Hommez
Geert Hommez
HBHugo De Bruyn
Hugo De Bruyn
SVStefan Vandeweghe
Stefan Vandeweghe
Purpose: The aim of this in vitro study is to evaluate the accuracy of implant position using mucosal supported surgical guides, produced by a desktop 3D printer. Methods: Ninety implants (Bone Level Roxolid, 4.1 mm × 10 mm, Straumann, Villerat, Switzerland) were placed in fifteen mandibular casts (Bonemodels, Castellón de la Plana, Spain). A mucosa-supported guide was designed and printed for each of the fifteen casts. After placement of the implants, the location was assessed by scanning the cast and scan bodies with an intra-oral scanner (Primescan®, Dentsply Sirona, York, PA, USA). Two comparisons were performed: one with the mucosa as a reference, and one where only the implants were aligned. Angular, coronal and apical deviations were measured. Results: The mean implant angular deviation for tissue and implant alignment were 3.25° (SD 1.69°) and 2.39° (SD 1.42°) respectively, the coronal deviation 0.82 mm (SD 0.43 mm) and 0.45 mm (SD 0.31 mm) and the apical deviation 0.99 mm (SD 0.45 mm) and 0.71 mm (SD 0.43 mm). All three variables were significantly different between the tissue and implant alignment (p < 0.001). Conclusion: Based on the results of this study, we conclude that guided implant surgery using desktop 3D printed mucosa-supported guides has a clinically acceptable level of accuracy. The resilience of the mucosa has a negative effect on the guide stability and increases the deviation in implant position.