The small impact of the geomagnetic field enables a magnetic tensor gradiometer to be easily installed on the flight platform for airborne geophysical exploration, especially for the detection of shallow buried mines and magnetic moving targets. Using the fluxgates as the core components, the gradiometer has the advantages of wide temperature range, low cost, and high resolution, but has the disadvantage of relatively low accuracy. This is because of the scale factor error, the nonorthogonal error, the misalignment, the zero offset, the dynamic error in a fluxgate, and the inconsistency among the error of fluxgates. In this letter, a correction method for a towed airborne magnetic tensor gradiometer is proposed that is composed of four fluxgates arranged in a cross-shaped structure. The theoretical framework of the proposed method is based on the static error model and the dynamic characteristics of single fluxgate, the feature that the gradient tensor of the geomagnetic field at high altitude is approximately zero, and on the phenomenon that the unchanged tensor rotation as a result of nonuniform magnetic field on the ground can indicate the inconsistency of the scale factors among different tensor components. The actual flight results using a helicopter have demonstrated and validated the performance and effectiveness of the proposed method. The improvement ratios of the field tensor components are from 359.6 to 1765, and the RMS of each component has reached to the level of 1 nT/m.
28 May 2020 in IEEE Geoscience and Remote Sensing Letters
Determination of the magnetic dipole moment of a spacecraft is a key issue for magnetic cleanliness and attitude control of various space scientific spacecraft. Two main methods, namely the multiple magnetic dipole modeling method and near-field analysis, have been used with good results inside a coil facility for prelaunch magnetic testing of a spacecraft. When field-canceling coil sets are unavailable, or coil feedback controls are inadequate to compensate for time-varying geomagnetic fields, determination of the magnetic signature of a spacecraft from measurements of field components is compromised. Therefore, we propose a magnetic dipole moment determination method using magnetic gradient tensor data without any coil facility, which is based on the fact that the time variation of the gradient tensor of the geomagnetic field is very small compared with that of field. We improve the near-field analysis method by expanding the magnetic gradient tensor in a series of spherical harmonics, obtain sets of near-field equations using Fourier analysis, and solve these equations to determine the dipole-moment components. The proposed tensor method can effectively suppress the interference from time variations of ambient magnetic fields. Simulations and experiments have been conducted to prove the validity, robustness, and accuracy of the tensor method.
29 April 2015 in IEEE Transactions on Instrumentation and Measurement
A magnetic tensor gradiometer is used to measure the spatial derivatives of three orthogonal magnetic field components. Being relatively insensitive to the geomagnetic field affords it the capability of being loaded onto flying platforms to conduct an airborne geophysical survey. It is especially suitable for exploring shallow buried mines and moving magnetic targets. The aerodynamic model was provided by the open source flight simulator, FlightGear. Estimations of the magnetic gradient tensor model of the magnetic dipole, the magnetic interference model of the aircraft, and the error model of the measuring device were all used to investigate the effects of flight on the airborne magnetic gradient tensor measurement system (AMGTMS). A thorough analysis of its causes, such as the vibration of the aircraft, the different rotating sequences of the coordinate system, and the reasonable sequence of data processing, was also done. The results can be applied to the guide design, integration, calibration, and data processing of the AMGTMS, thus reducing the research and development risk.
A ferromagnetic vehicle, such as a submarine, magnetized by the Earth’s magnetic field produces a magnetic anomaly field, and the tracking of moving targets can be realized through real-time analysis of magnetic data. At present, there are few tracking methods based on magnetic field vectors and their gradient tensor. In this paper, the magnetic field vector and its gradient tensor are used to calculate equivalent magnetic force. It shows the direction of the vector between the detector and the tracking targets for controlling the direction of motion of the detector and achieving the purpose of tracking. Compared with existing positioning methods, the proposed method is relatively less affected by instrument resolution and noise and maintains robustness when the velocity vectors of multiple magnetic targets change randomly.
An airborne fluxgate magnetic tensor gradiometer is built on fluxgates to measure directional derivatives of the magnetic field. It has been used to carry out many geophysical exploration programs quickly and efficiently. However, two key issues greatly reduce the data quality of a tensor gradiometer. One is that the fluxgate magnetic tensor gradiometer suffers various errors, such as scale drift, non-orthogonality, misalignment, zero offset, dynamic, and nonlinear errors of individual fluxgates, along with differences between characteristics of fluxgates. The other is that manoeuvring an aircraft flying in the geomagnetic field can generate magnetic interference effects on a tensor gradiometer. Regarding the common airborne fluxgate magnetic tensor gradiometer that has a cross-shaped structure, we have proposed the magnetic interference model of the aircraft and the error model of a single fluxgate. Then we have seamlessly combined these two models into the unified calibration model of a tensor gradiometer by a recursive method. Finally, we have simultaneously determined the correction coefficients and the magnetic properties of the aircraft by a calibration flight at high altitude in an area of low magnetic gradient. We have evaluated the performance of the proposed method through simulation and actual flight results using a microlight aircraft. The root-mean-square noise of each component has reached the level of less than 1.5 nT/m, and the improvement ratios are from 4096 to 17444 in terms of the measured field data of tensor components. The proposed method reduces the reliance of the installation on the aircraft and can easily be applied to other tensor gradiometers, such as airborne superconducting magnetic tensor gradiometers.
12 May 2021 in IEEE Transactions on Instrumentation and Measurement
The magnetic gradient tensor is the spatial rate of change of the magnetic vector along the three axes of the Cartesian coordinate system. It is particularly suitable for aeromagnetic surveys because it is relatively insensitive to temporal changes and regional variations of the geomagnetic field. However, the complexity of the flight environment and defects in the existing calibration methods for airborne magnetic tensor gradiometers cannot guarantee the measurement accuracy of tensor data. Research shows that the generalized Hilbert transform can convert total-field gradients, measured over an extensive survey area, into the magnetic gradient tensor components, so a high-precision total-field gradiometer can be employed to calibrate a magnetic tensor gradiometer, using a generalized Hilbert transform calibration method (GHTCM). However, practical survey conditions cannot meet the requirements of the generalized Hilbert transform, which degrades the accuracy of GHTCM. Based on the theory of the generalized Hilbert transform, we first analyze the error sources and error mechanisms of the GHTCM according to the differences between real and ideal survey conditions and then build models to design an appropriate evaluation algorithm for the accuracy of the GHTCM. Simulation experiments based on the open-source flight simulator, FlightGear, and a practical flight experiment are designed. The results indicate that the proposed method can correctly evaluate the accuracy of the GHTCM. This evaluation algorithm is the basis of obtaining the high-precision calibration data for practical airborne magnetic gradient tensor in the survey.