Süleyman Aşır

Dr. Süleyman Aşır

Materials Science and Nanotechnology Engineering, Near East University, Nicosia, Lefkosía, Cyprus
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 March 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
PPPwadubashiyi Pwavodi
Pwadubashiyi Pwavodi
HÖHazal Özyurt
Hazal Özyurt
Süleyman AşırSüleyman Aşır
Süleyman Aşır
MOMehmet Ozsoz
Mehmet Ozsoz
Phenolic compounds contain classes of flavonoids and non-flavonoids, which occur naturally as secondary metabolites in plants. These compounds, when consumed in food substances, improve human health because of their antioxidant properties against oxidative damage diseases. In this study, an electrochemical sensor was developed using a carbon paste electrode (CPE) modified with Fe3O4 nanoparticles (MCPE) for the electrosensitive determination of sinapic acid, syringic acid, and rutin. The characterization techniques adapted for CPE, MCPE electrodes, and the solution interface were cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). Scan rate and pH were the parameters subjected to optimization studies for the determination of phenolic compounds. The incorporation of Fe3O4 nanoparticles to the CPE as a sensor showed excellent sensitivity, selectivity, repeatability, reproducibility, stability, and low preparation cost. The limits of detection (LOD) obtained were 2.2 × 10−7 M for sinapic acid, 2.6 × 10−7 M for syringic acid, and 0.8 × 10−7 M for rutin, respectively. The fabricated electrochemical sensor was applied to determine phenolic compounds in real samples of red and white wine.

6 January 2022 in Journal of Apicultural Research
Verified
Journal Article
Closed access
BOBeste Oymen
Beste Oymen
Süleyman AşırSüleyman Aşır
Süleyman Aşır
Deniz TürkmenDeniz Türkmen
Deniz Türkmen
Adil DenizliAdil Denizli
Adil Denizli
This paper presents a modified QuEChERS method to determine 346 pesticide residues in honey by LC/MS-MS and GC/MS-MS. Acetate buffered acetonitrile extraction followed by dispersive SPE clean-up with C18-E, PSA and MgSO4 sorbents were used for sample preparation. This method was validated according to the European Union SANTE/2019/12682 guidelines. Acceptable values were obtained for the linearity, the limit of detection (0.001–0.003 mg/kg), limit of quantification (0.002–0.008 mg/kg), trueness (for the four tested levels, the recovery assays values were between 76 and 112%), precision (RSD ≤20.0%) and measurement uncertainty tests (<50%). The method was used for the analysis of 100 honey samples from Northern Cyprus and residues of 4 pesticides (coumaphos, thiamethoxam, N-(2,4-dimethylphenyl)formamide, piperonyl butoxide) were quantified in 42 honey samples. Coumaphos (29%) and N-(2,4-dimethylphenyl)formamide (11%) were the residues frequently detected in the samples. N-(2,4-dimethylphenyl)formamide concentrations (0.56 and 0.84 mg/kg) were determined above the MRL limits (0.2 mg/kg) in two samples. This study shows that LC/MS-MS and GC/MS-MS in combination with modified QuEChERS can be used to routinely scan pesticide residues in honey samples and direct contamination with acaricides/veterinary drugs applied in the treatment of plagues in the hive during honey harvest is the main source of honey pollution in Northern Cyprus.

18 January 2024 in International Journal of Food Science and Technology
Verified
Journal Article
Open access
MKMehmet Karagözlü
Mehmet Karagözlü
PAPerihan Adun
Perihan Adun
MOMehmet Ozsoz
Mehmet Ozsoz
Süleyman AşırSüleyman Aşır
Süleyman Aşır
Summary: A quick, simple, environmentally friendly and cost‐effective screening approach for identifying parameters of adulteration in cold‐pressed olive oil (CPOO) was developed. The technique focused on the electrochemical examination of the peak of alpha‐tocopherol oxidation on pencil graphite electrode (PGE). Rapeseed oil (RO), sunflower oil (SO), and corn oil (CO) were added to local CPOO in varying amounts, and the mixtures were then tested by differential pulse voltammetry (DPV) on PGE. Voltammetric analysis of CPOO and its artificially created mixtures with other commercial oils have demonstrated statistically significant discrimination with an ability to detect adulteration under the level of 10% on weight basis. The method's relative standard deviation (RSD) was 20%, and the α‐tocopherol in CPOO cut‐off value was 30.98 ± 12.57 nA. As far as our knowledge, no data on utilisation of voltammetric techniques for the detection of olive oil adulteration are available to date by using PGE. The results showed that the developed method is capable of detection of adulteration in natural olive oils without any pretreatment.

13 March 2023 in The Journal of Supercomputing
Verified
Journal Article
Closed access
PDF file
DKDevrim Kayali
Devrim Kayali
Nemah ShamaNemah Shama
Nemah Shama
Süleyman AşırSüleyman Aşır
Süleyman Aşır
Kamil DimililerKamil Dimililer
Kamil Dimililer

22 February 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
Nemah ShamaNemah Shama
Nemah Shama
Süleyman AşırSüleyman Aşır
Süleyman Aşır
MOMehmet Ozsoz
Mehmet Ozsoz
ILGIM GÖKTÜRKILGIM GÖKTÜRK
ILGIM GÖKTÜRK
Deniz TürkmenDeniz Türkmen
Deniz Türkmen
Adil DenizliAdil Denizli
Adil Denizli
A molecularly imprinted polymer-based pencil graphite electrode (MIP PGE) sensor, modified with gold nanoparticles, was utilized for the detection of dopamine in the presence of other biochemical compounds using cyclic voltammetry (CV) and differential pulse voltammetry (DPV), depending on its strong electroactivity function. The pulse voltammetry methods recorded the highest response. In addition to the high oxidation rate of DA and the other biomolecule interferences available in the sample matrix used, which cause overlapping voltammograms, we aimed to differentiate them in a highly sensitive limit of detection range. The calibration curves for DA were obtained using the CV and DPV over the concentration range of 0.395–3.96 nM in 0.1 M phosphate buffer solution (PBS) at pH 7.4 with a correlation coefficient of 0.996 and a detection limit of 0.193 nM. The electrochemical technique was employed to detect DA molecules quantitatively in human blood plasma selected as real samples without applying any pre-treatment processes. MIP electrodes proved their ability to detect DA with high selectivity, even with epinephrine and norepinephrine competitor molecules and interferences, such as ascorbic acid (AA). The high level of recognition achieved by molecularly imprinted polymers (MIPs) is essential for many biological and pharmaceutical studies.

23 March 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
BOBeste Oymen
Beste Oymen
MJMitra Jalilzadeh
Mitra Jalilzadeh
Fatma YılmazFatma Yılmaz
Fatma Yılmaz
Süleyman AşırSüleyman Aşır
Süleyman Aşır
Deniz TürkmenDeniz Türkmen
Deniz Türkmen
Adil DenizliAdil Denizli
Adil Denizli
Here, a molecular imprinting technique was employed to create an SPR-based nanosensor for the selective and sensitive detection of organophosphate-based coumaphos, a toxic insecticide/veterinary drug often used. To achieve this, UV polymerization was used to create polymeric nanofilms using N-methacryloyl-l-cysteine methyl ester, ethylene glycol dimethacrylate, and 2-hydroxyethyl methacrylate, which are functional monomers, cross-linkers, and hydrophilicity enabling agents, respectively. Several methods, including scanning electron microscopy (SEM), atomic force microscopy (AFM), and contact angle (CA) analyses, were used to characterize the nanofilms. Using coumaphos-imprinted SPR (CIP-SPR) and non-imprinted SPR (NIP-SPR) nanosensor chips, the kinetic evaluations of coumaphos sensing were investigated. The created CIP-SPR nanosensor demonstrated high selectivity to the coumaphos molecule compared to similar competitor molecules, including diazinon, pirimiphos-methyl, pyridaphenthion, phosalone, N-2,4(dimethylphenyl) formamide, 2,4-dimethylaniline, dimethoate, and phosmet. Additionally, there is a magnificent linear relationship for the concentration range of 0.1–250 ppb, with a low limit of detection (LOD) and limit of quantification (LOQ) of 0.001 and 0.003 ppb, respectively, and a high imprinting factor (I.F.4.4) for coumaphos. The Langmuir adsorption model is the best appropriate thermodynamic approach for the nanosensor. Intraday trials were performed three times with five repetitions to statistically evaluate the CIP-SPR nanosensor’s reusability. Reusability investigations for the two weeks of interday analyses also indicated the three-dimensional stability of the CIP-SPR nanosensor. The remarkable reusability and reproducibility of the procedure are indicated by an RSD% result of less than 1.5. Therefore, it has been determined that the generated CIP-SPR nanosensors are highly selective, rapidly responsive, simple to use, reusable, and sensitive for coumaphos detection in an aqueous solution. An amino acid, which was used to detect coumaphos, included a CIP-SPR nanosensor manufactured without complicated coupling methods and labelling processes. Liquid chromatography with tandem mass spectrometry (LC/MS-MS) studies was performed for the validation studies of the SPR.