Seon-Chil Kim

Prof. Seon-Chil Kim

Keimyung University School of Medicine
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 April 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Seon-Chil KimSeon-Chil Kim
Seon-Chil Kim
In the field of medical radiation shielding, there is an extensive body of research on process technologies for ecofriendly shielding materials that could replace lead. In particular, the particle size and arrangement of the shielding material when blended with a polymer material affect shielding performance. In this study, we observed how the particle size of the shielding material affects shielding performance. Performance and particle structure were observed for every shielding sheet, which were fabricated by mixing microparticles and nanoparticles with a polymer material using the same process. We observed that the smaller the particle size was, the higher both the clustering and shielding effects in the high-energy region. Thus, shielding performance can be improved. In the low-dose region, the effect of particle size on shielding performance was insignificant. Moreover, the shielding sheet in which nanoparticles and microsized particles were mixed showed similar performance to that of the shielding sheet containing only microsized particles. Findings indicate that, when fabricating a shielding sheet using a polymer material, the smaller the particles in the high-energy region are, the better the shielding performance is. However, in the low-energy region, the effect of the particles is insignificant.

Seon-Chil KimSeon-Chil Kim
Seon-Chil Kim
HLHojun Lee
Hojun Lee
HLHyunsuk Lee
Hyunsuk Lee
GKGaeun Kim
Gaeun Kim
JSJeong-Heon Song
Jeong-Heon Song
Children diagnosed with attention deficit hyperactivity disorder (ADHD) require early intervention and sustained treatment. This study used a game-based digital treatment planning NeuroWorld DTx to analyze the impact on attention and cognitive function in children with ADHD. Thirty children diagnosed with ADHD were recruited and subjected to a four-week NeuroWorld DTx digital treatment. To assess the impact of the digital therapeutic therapy on children’s attention, we used the comprehension attention test (CAT) and Korean ADHD Rating Scale (K-ARS). Clinical global impression (CGI) and the Korean-child behavior checklist (K-CBCL 6–18) were used to examine the degree of improvement in ADHD. After four weeks, significant differences in the sensitivity and response style indices were noted, as compared with the baseline in the CAT test; in the case of K-ARS and CGI, a moderate decrease in ADHD was confirmed. The study achieved better results for the “total behavior problems” belonging to the K-CBCL assessment. Game-based digital therapy intervention can be a treatment method that elicits interest and satisfaction in children with ADHD and can be used as an adjunct to drug therapy to improve the quality of life and strengthen attention in children with symptoms of ADHD.

21 July 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Seon-Chil KimSeon-Chil Kim
Seon-Chil Kim
YCYoung Sik Cho
Young Sik Cho
Urinalysis, an elementary chemical reaction-based method for analyzing color conversion factors, facilitates examination of pathological conditions in the human body. Recently, considerable urinalysis-centered research has been conducted on the analysis of urine dipstick colors using smartphone cameras; however, such methods have a drawback: the problem of reproducibility of accuracy through quantitative analysis. In this study, to solve this problem, the function values for each concentration of a range of analysis factors were implemented in an algorithm through urine dipstick RGB semi-quantitative color analysis to enable real-time results. Herein, pH, glucose, ketones, hemoglobin, bilirubin, protein (albumin), and nitrites were selected as analysis factors, and the accuracy levels of the existing equipment and the test application were compared and evaluated using artificial urine. In the semi-quantitative analysis, the red (R), green (G), and blue (B) characteristic values were analyzed by extracting the RGB characteristic values of the analysis factors for each concentration of artificial urine and obtaining linear function values. In addition, to improve the reproducibility of detection accuracy, the measurement value of the existing test equipment was set to an absolute value; using a machine-learning technique, the confusion matrix, we attempted to stabilize test results that vary with environment.

14 February 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Seon-Chil KimSeon-Chil Kim
Seon-Chil Kim
As the scope of radiation use in medical and industrial fields has expanded, interest in radiation shielding is increasing. Most existing radiation shields use Pb-based products, primarily in the form of a laminated sheet, which requires attention as fine cracks may occur depending on the usage and storage conditions. The weight of the sheets limits users’ activities, and they pose a risk of heavy metal contamination. To address these problems, this study proposed a shielding fiber with improved flexibility and workability, and thus, produce a shielding garment. Masterbatches of polyethylene terephthalate (PET) fiber were manufactured using the eco-friendly materials, BaSO4 and Bi2O3. Yarns were fabricated by the melt spinning process, and fabrics were woven. With 5 wt% of shielding material, the yarns’ shield against radiation and was sufficiently strong for fabric weaving. The fibers’ radiation shielding averaged 9–13%, with the Bi2O3 fiber displaying better shielding performance than the BaSO4. It is believed that the findings of this study on improving the yarn manufacturing process could be applied for protection against low-dose and scattered rays in medical applications and for aerospace radiation protection. In addition, the proposed shielding fibers’ flexibility makes them suitable for future use in the production of various radiation shields.

15 September 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Seon-Chil KimSeon-Chil Kim
Seon-Chil Kim
HLHyunsuk Lee
Hyunsuk Lee
Early detection and repeated learning training of children with intellectual disabilities are important factors that are directly related to the quality of future life of such children. However, implementation of such programs is challenging, as the subjects are still children. Therefore, motivation and interest are important for children with intellectual disabilities to carry out continuous training. In this study, Neuro-World, a game-based cognitive training program, was proposed for motivation and interest induction, and its effectiveness was compared with that of a conventional cognitive training program through analysis after both programs were implemented by professional therapists. The pre-test and post-test results of the game-based cognitive training program were statistically significant and showed superiority in the comparison with the conventional program. Therefore, the game-based cognitive training program developed in this study through digital media is expected to be effective in improving cognitive learning ability.

13 July 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Seon-Chil KimSeon-Chil Kim
Seon-Chil Kim
Radiation exposure in medical institutions is mainly due to low doses. Low-dose radiation mainly means scattered radiation, and such scattered radiation can be shielded with a lightweight shielding suit. In this study, the shielding performance of shielding fabrics woven by winding polyethylene (PE) yarn around a 30 μm tungsten wire was evaluated. To improve the shielding performance, an air pressure dispersion process of coating tungsten nanopowder on the fiber was developed. The radiation shielding effectiveness of the shielding fibers with and without dispersed tungsten nanopowder were compared by measuring the spatial dose inside the diagnostic X-ray imaging room of a medical institution. The results of the experiment confirmed that the fabric coated with tungsten nanopowder improved the shielding performance of the general tungsten fiber by approximately 15% and provided relatively effective low-dose radiation shielding at approximately 1.2 m of the X-ray imaging equipment. This study shows that tungsten fiber can be helpful in manufacturing lightweight shielding clothing for protection from scattered radiation in medical institutions.