Thomas Schauer

Dr. Thomas Schauer

Technische Universität Berlin, Control Systems Group
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2014 in Sensors
Verified
Journal Article
Open access
PDF file
TSThomas Seel
Thomas Seel
JRJörg Raisch
Jörg Raisch
TSThomas Schauer
Thomas Schauer
This contribution is concerned with joint angle calculation based on inertial measurement data in the context of human motion analysis. Unlike most robotic devices, the human body lacks even surfaces and right angles. Therefore, we focus on methods that avoid assuming certain orientations in which the sensors are mounted with respect to the body segments. After a review of available methods that may cope with this challenge, we present a set of new methods for: (1) joint axis and position identification; and (2) flexion/extension joint angle measurement. In particular, we propose methods that use only gyroscopes and accelerometers and, therefore, do not rely on a homogeneous magnetic field. We provide results from gait trials of a transfemoral amputee in which we compare the inertial measurement unit (IMU)-based methods to an optical 3D motion capture system. Unlike most authors, we place the optical markers on anatomical landmarks instead of attaching them to the IMUs. Root mean square errors of the knee flexion/extension angles are found to be less than 1° on the prosthesis and about 3° on the human leg. For the plantar/dorsiflexion of the ankle, both deviations are about 1°.

1 January 2013 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
Alessandra PedrocchiAlessandra Pedrocchi
Alessandra Pedrocchi
SFSimona Ferrante
Simona Ferrante
EAEmilia Ambrosini
Emilia Ambrosini
MGMarta Gandolla
Marta Gandolla
CCClaudia Casellato
Claudia Casellato
Giancarlo FerrignoGiancarlo Ferrigno
Giancarlo Ferrigno
MUNDUS is an assistive framework for recovering direct interaction capability of severely motor impaired people based on arm reaching and hand functions. It aims at achieving personalization, modularity and maximization of the user’s direct involvement in assistive systems. To this, MUNDUS exploits any residual control of the end-user and can be adapted to the level of severity or to the progression of the disease allowing the user to voluntarily interact with the environment. MUNDUS target pathologies are high-level spinal cord injury (SCI) and neurodegenerative and genetic neuromuscular diseases, such as amyotrophic lateral sclerosis, Friedreich ataxia, and multiple sclerosis (MS). The system can be alternatively driven by residual voluntary muscular activation, head/eye motion, and brain signals. MUNDUS modularly combines an antigravity lightweight and non-cumbersome exoskeleton, closed-loop controlled Neuromuscular Electrical Stimulation for arm and hand motion, and potentially a motorized hand orthosis, for grasping interactive objects. The definition of the requirements and of the interaction tasks were designed by a focus group with experts and a questionnaire with 36 potential end-users. Five end-users (3 SCI and 2 MS) tested the system in the configuration suitable to their specific level of impairment. They performed two exemplary tasks: reaching different points in the working volume and drinking. Three experts evaluated over a 3-level score (from 0, unsuccessful, to 2, completely functional) the execution of each assisted sub-action. The functionality of all modules has been successfully demonstrated. User’s intention was detected with a 100% success. Averaging all subjects and tasks, the minimum evaluation score obtained was 1.13 ± 0.99 for the release of the handle during the drinking task, whilst all the other sub-actions achieved a mean value above 1.6. All users, but one, subjectively perceived the usefulness of the assistance and could easily control the system. Donning time ranged from 6 to 65 minutes, scaled on the configuration complexity. The MUNDUS platform provides functional assistance to daily life activities; the modules integration depends on the user’s need, the functionality of the system have been demonstrated for all the possible configurations, and preliminary assessment of usability and acceptance is promising.

1 March 2016 in Control Engineering Practice
Verified
Journal Article
Closed access
TSThomas Seel
Thomas Seel
CWCordula Werner
Cordula Werner
JRJörg Raisch
Jörg Raisch
TSThomas Schauer
Thomas Schauer

15 March 2004 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
KHK.J. Hunt
K.J. Hunt
BSB. Stone
B. Stone
NNN.-O. Negard
N.-O. Negard
TSThomas Schauer
Thomas Schauer
MFM.H. Fraser
M.H. Fraser
SGS. Grant
S. Grant
Aim: The aim of this study was to investigate feedback control strategies for integration of electric motor assist and functional electrical stimulation (FES) for paraplegic cycling, with particular focus on development of a testbed for exercise testing in FES cycling, in which both cycling cadence and workrate are simultaneously well controlled and contemporary physiological measures of exercise performance derived. A second aim was to investigate the possible benefits of the approach for mobile, recreational cycling. Methods: A recumbent tricycle with an auxiliary electric motor is used, which is adapted for paraplegic users, and instrumented for stimulation control. We propose a novel integrated control strategy which simultaneously provides feedback control of leg power output (via automatic adjustment of stimulation intensity) and cycling cadence (via electric motor control). Both loops are designed using system identification and analytical (model-based) feedback design methods. Ventilatory and pulmonary gas exchange response profiles are derived using a portable system for real-time breath-by-breath acquisition. Results: We provide indicative results from one paraplegic subject in which a series of feedback-control tests illustrate accurate control of cycling cadence, leg power control, and external disturbance rejection. We also provide physiological response profiles from a submaximal exercise step test and a maximal incremental exercise test, as facilitated by the control strategy. Conclusion: The integrated control strategy is effective in facilitating exercise testing under conditions of well-controlled cadence and power output. Our control approach significantly extends the achievable workrate range and enhances exercise-test sensitivity for FES cycling, thus allowing a more stringent characterization of physiological response profiles and estimation of key parameters of aerobic function. We further conclude that the control approach can significantly improve the overall performance of mobile recreational cycling.

1 September 2005 in Control Engineering Practice
Verified
Journal Article
Closed access
TSThomas Schauer
Thomas Schauer
NNN.-O. Negård
N.-O. Negård
FPF. Previdi
F. Previdi
KHK.J. Hunt
K.J. Hunt
MFM.H. Fraser
M.H. Fraser
JRJ. Raisch
J. Raisch

1 October 2012
Verified
Conference Paper
Closed access
TSThomas Seel
Thomas Seel
TSThomas Schauer
Thomas Schauer
JRJorg Raisch
Jorg Raisch
We consider 6d inertial measurement units (IMU) attached to rigid bodies, e.g. human limb segments or links of a robotic manipulator, which are connected by hinge joints and spheroidal joints. Novel methods for joint axis estimation and joint position estimation are presented that exploit the kinematic constraints induced by these two types of joints. The presented methods do not require any knowledge about the sensor units' positions or orientations and do not include integration, i.e. they are insensitive to measurement bias. By means of a three-links simulation model, the estimation algorithms are validated and convergence is analyzed. Finally, the algorithms are tested using experimental data from IMU-based human gait analysis.