Timm Krüger

Dr. Timm Krüger

University of Edinburgh
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017
Verified
Book
Closed access
TKTimm Krüger
Timm Krüger
HKHalim Kusumaatmaja
Halim Kusumaatmaja
AKAlexandr Kuzmin
Alexandr Kuzmin
OSOrest Shardt
Orest Shardt
GSGoncalo Silva
Goncalo Silva
EVErlend Magnus Viggen
Erlend Magnus Viggen

1 June 2011 in Computers & Mathematics with Applications
Verified
Journal Article
Closed access
TKTimm Krüger
Timm Krüger
FVF. Varnik
F. Varnik
DRD. Raabe
D. Raabe

20 January 2020 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
Sajad Razavi BazazSajad Razavi Bazaz
Sajad Razavi Bazaz
AMAli Mashhadian
Ali Mashhadian
AEAbbas Ehsani
Abbas Ehsani
Suvash SahaSuvash Saha
Suvash Saha
TKTimm Krüger
Timm Krüger
Majid Ebrahimi WarkianiMajid Ebrahimi Warkiani
Majid Ebrahimi Warkiani
Schematic illustration of various kinds of geometries used for inertial microfluidics.

1 September 2014 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
TKTimm Krüger
Timm Krüger
DHDavid Holmes
David Holmes
PCPeter V. Coveney
Peter V. Coveney
We show, via three-dimensional immersed-boundary-finite-element-lattice-Boltzmann simulations, that deformability-based red blood cell (RBC) separation in deterministic lateral displacement (DLD) devices is possible. This is due to the deformability-dependent lateral extension of RBCs and enables us to predict a priori which RBCs will be displaced in a given DLD geometry. Several diseases affect the deformability of human cells. Malaria-infected RBCs, for example, tend to become stiffer than their healthy counterparts. It is therefore desirable to design microfluidic devices which can detect diseases based on the cells' deformability fingerprint, rather than preparing samples using expensive and time-consuming biochemical preparation steps. Our findings should be helpful in the development of new methods for sorting cells and particles by deformability.

6 October 2014 in Journal of The Royal Society Interface
Verified
Journal Article
Open access
MBMiguel O. Bernabeu
Miguel O. Bernabeu
MJMartin L. Jones
Martin L. Jones
JNJens H. Nielsen
Jens H. Nielsen
TKTimm Krüger
Timm Krüger
RNRupert W. Nash
Rupert W. Nash
PCPeter V. Coveney
Peter V. Coveney
There is currently limited understanding of the role played by haemodynamic forces on the processes governing vascular development. One of many obstacles to be overcome is being able to measure those forces, at the required resolution level, on vessels only a few micrometres thick. In this paper, we present an in silico method for the computation of the haemodynamic forces experienced by murine retinal vasculature (a widely used vascular development animal model) beyond what is measurable experimentally. Our results show that it is possible to reconstruct high-resolution three-dimensional geometrical models directly from samples of retinal vasculature and that the lattice-Boltzmann algorithm can be used to obtain accurate estimates of the haemodynamics in these domains. We generate flow models from samples obtained at postnatal days (P) 5 and 6. Our simulations show important differences between the flow patterns recovered in both cases, including observations of regression occurring in areas where wall shear stress (WSS) gradients exist. We propose two possible mechanisms to account for the observed increase in velocity and WSS between P5 and P6: (i) the measured reduction in typical vessel diameter between both time points and (ii) the reduction in network density triggered by the pruning process. The methodology developed herein is applicable to other biomedical domains where microvasculature can be imaged but experimental flow measurements are unavailable or difficult to obtain.