Thai-Thanh Nguyen

Dr. Thai-Thanh Nguyen

Clarkson University
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2024 in Electric Power Systems Research
Verified
Journal Article
Closed access
LVLinh Vu
Linh Vu
Thai-Thanh NguyenThai-Thanh Nguyen
Thai-Thanh Nguyen
BNBang Le-Huy Nguyen
Bang Le-Huy Nguyen
IAIsfakul Anam
Isfakul Anam
TVTuyen Vu
Tuyen Vu

13 January 2023 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
Thai-Thanh NguyenThai-Thanh Nguyen
Thai-Thanh Nguyen
TVTuyen Vu
Tuyen Vu
TOThomas Ortmeyer
Thomas Ortmeyer
GSGeorge Stefopoulos
George Stefopoulos
GPGreg Pedrick
Greg Pedrick
JMJason MacDowell
Jason MacDowell
The real-time models of offshore wind turbine generators complied with industry standards are presented in this paper. The developed models provide essential capabilities for future electromagnetic transient controls and testing offshore wind farms, such as low-voltage ride-through, active/reactive power support, transient current limiting. Furthermore, the proposed models provide an additional capability of controlling negative sequence current, which meets the future requirements for protecting wind farm systems. This paper presents average-value and detailed switching real-time models in the Opal-RT real-time simulator. The efficacy of the proposed real-time models in terms of computational efficiency is demonstrated by comparing them with the non-real-time models. Extensive case studies are performed to demonstrate the control functions of the proposed models, such as dynamic-wind condition, power curtailment, low-voltage and fault ride-through, negative sequence current control, etc. The wind turbine model validation against the generic model presented by the Western Electricity Coordinating Council (WECC) is conducted to show their compliance with industry standards utilized by WECC. A real-time model of a 450 MW offshore wind farm is developed to show the feasibility of large-scale wind farm modeling.

28 December 2021 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
MKMaryam Mahmoudi Koutenaei
Maryam Mahmoudi Koutenaei
Thai-Thanh NguyenThai-Thanh Nguyen
Thai-Thanh Nguyen
TVTuyen Vu
Tuyen Vu
SPSumit Paudyal
Sumit Paudyal
RHRob Hovsapian
Rob Hovsapian
As the penetration of power-electronics based smart inverters (SIs) is increasing in distribution grids, it adds computational challenges in solving dynamic models of large-scale distribution feeders. Voltage and reactive power (Volt/VAr), and voltage and active power (Volt/Watt) dynamics have been analyzed at slower time scales akin to the control of legacy grid devices. However, smart inverters, being power-electronics based devices, can provide dynamic active/reactive power support at a faster time scale, which necessitates Volt/VAr and Volt/Watt dynamics to be analyzed at a faster time scale. The existing dynamic models are overly detailed and computationally intractable for distribution feeders with a large number of inverters. In this context, this proposed work aims towards developing a computationally tractable, scalable, and accurate phasor-based model for dynamic Volt/VAr and Volt/Watt analyses of large distribution systems with high penetration of smart inverters. Case studies demonstrate that the proposed phasor-based model sufficiently captures the Volt/VAr and Volt/Watt dynamics, and is computationally faster by one order of magnitude compared to the average model and by two orders of magnitude compared to the detailed switching model. Case studies also demonstrate the efficacy and scalability of the proposed model in analyzing Volt/VAr and Volt/Watt dynamics of large-scale power networks with hundreds of SIs.

10 September 2024 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Thai-Thanh NguyenThai-Thanh Nguyen
Thai-Thanh Nguyen
RKRahul Kadavil
Rahul Kadavil
HHHossein Hooshyar
Hossein Hooshyar
In this paper, a real-time cyber-physical simulation (RTCPS) testbed is developed to assess the cybersecurity of large-scale power systems. The simulation testbed includes real-time simulations of power grids and communication networks, allowing for the integration of physical hardware and providing a realistic representation of power system operations. Real-time simulators from OPAL-RT and RTDS technologies are used to simulate power grids, whereas EXata network modeling is used to emulate the communication network in real time. The communication network within the testbed includes information technology (IT) and operational technology (OT) systems, which enable a comprehensive assessment of the impact of cybersecurity issues on power systems. Since the developed simulation testbed comprises various simulation tools, multiple scripts are developed to automate the simulation and launch cyber attacks on communication networks. These scripts allow the testbed to simulate a large number of scenarios with minimal effort, which is crucial in collecting data for training machine learning models. Various realistic attacks on the IT and OT networks, including phishing email attack, steal credentials, denial of service, remote access attack, and man-in-the-middle attack will be presented. The setup of the RTCPS testbed for a simple scenario is described, allowing researchers to understand and reproduce the simulation. Furthermore, an additional setup for a large-scale cyber-physical simulation scenario is presented to demonstrate the capabilities of the RTCPS testbed.

16 August 2022 in IEEE Access
Verified
Journal Article
Open access
Woon-Gyu LeeWoon-Gyu Lee
Woon-Gyu Lee
Thai-Thanh NguyenThai-Thanh Nguyen
Thai-Thanh Nguyen
HYHyeong-Jun Yoo
Hyeong-Jun Yoo
HKHak-Man Kim
Hak-Man Kim
The energy management systems used in microgrid systems are either centralized or decentralized. The centralized method is easy to implement, but has low reliability and it is computationally intensive due to its reliance on a single control unit. The decentralized control is a more reliable strategy as multiple units are coordinated to manage the microgrid system, however, its algorithm and implementation are complicated for long-term operation. This paper proposes a consensus-based hybrid multi-agent management system including both centralized and decentralized agents taking advantages of both methods into account. The hierarchical cooperative optimization system is adapted for the distributed economic dispatch. The primary control layer is responsible for the voltage and frequency regulations whereas the secondary control layer is implemented in a consensus-based distributed multi-agent control scheme for optimal microgrid management. The centralized agent is used to optimally schedule the energy storage system. The proposed hybrid control strategy consistently maintains the economic operation and demand load balance of the microgrid system under load uncertainty. A comparison study with the centralized control strategy is presented to demonstrate the effectiveness of the proposed control strategy. The feasibility of the proposed controller is validated by the control-hardware-in-the-loop simulation using OPAL-RT Technologies. Real-time simulation results show that the proposed hybrid strategy has a better optimization performance compared to the centralized strategy under load uncertainty conditions.

23 October 2017 in Energies
Verified
Journal Article
Open access
PDF file
VNVan-Vinh Nguyen
Van-Vinh Nguyen
HSHo-Ik Son
Ho-Ik Son
Thai-Thanh NguyenThai-Thanh Nguyen
Thai-Thanh Nguyen
HKHak-Man Kim
Hak-Man Kim
CKChan-Ki Kim
Chan-Ki Kim
The use of high voltage direct current (HVDC) circuit breakers (CBs) with the capabilities of bidirectional fault interruption, reclosing, and rebreaking can improve the reliable and safe operation of HVDC grids. Although several topologies of CBs have been proposed to perform these capabilities, the limitation of these topologies is either high on-state losses or long time interruption in the case bidirectional fault current interruption. Long time interruption results in the large magnitude of the fault current in the voltage source converter based HVDC (VSC-HVDC) system due to the high rate of rise of fault current. This paper proposes a new topology of hybrid CB (HCB) with lower conduction loss and lower interruption time to solve the problems. The proposed topology is based on the inverse current injection method, which uses the capacitor to enforce the fault current to zero. In the case of the bidirectional fault current interruption, the capacitor does not change its polarity after identifying the direction of fault current, which can reduce the interruption time accordingly. A switching control algorithm for the proposed topology is presented in detail. Different operation modes of proposed HCB, such as normal current mode, breaking fault current mode, discharging, and reversing capacitor voltage modes after clearing the fault, are considered in the proposed algorithm. The proposed topology with the switching control algorithm is tested in a simulation-based system. Different simulation scenarios such as temporary and permanent faults are carried out to verify the performance of the proposed topology. The simulation is performed in the Matlab/Simulink environment.