Electromyographical (EMG) signals have been frequently used to estimate human muscular torques. In the field of human-assistive robotics, these methods provide valuable information to provide effectively support to the user. However, their usability is strongly limited by the necessity of complex user-dependent and session-dependent calibration procedures, which confine their use to the laboratory environment. Nonetheless, an accurate estimate of muscle torque could be unnecessary to provide effective movement assistance to users. The natural ability of human central nervous system of adapting to external disturbances could compensate for a lower accuracy of the torque provided by the robot and maintain the movement accuracy unaltered, while the effort is reduced. In order to explore this possibility, in this paper we study the reaction of ten healthy subjects to the assistance provided through a proportional EMG control applied by an elbow powered exoskeleton. This system gives only a rough estimate of the user muscular torque but does not require any specific calibration. Experimental results clearly show that subjects adapt almost instantaneously to the assistance provided by the robot and can reduce their effort while keeping full control of the movement under different dynamic conditions (i.e., no alterations of movement accuracy are observed).
17 September 2012 in IEEE Transactions on Robotics
This paper presents the design and experimental testing of the robotic elbow exoskeleton NEUROBOTICS Elbow Exoskeleton (NEUROExos). The design of NEUROExos focused on three solutions that enable its use for poststroke physical rehabilitation. First, double-shelled links allow an ergonomic physical human-robot interface and, consequently, a comfortable interaction. Second, a four-degree-of-freedom passive mechanism, embedded in the link, allows the user's elbow and robot axes to be constantly aligned during movement. The robot axis can passively rotate on the frontal and horizontal planes 30° and 40°, respectively, and translate on the horizontal plane 30 mm. Finally, a variable impedance antagonistic actuation system allows NEUROExos to be controlled with two alternative strategies: independent control of the joint position and stiffness, for robot-in-charge rehabilitation mode, and near-zero impedance torque control, for patient-in-charge rehabilitation mode. In robot-in-charge mode, the passive joint stiffness can be changed in the range of 24-56 N·m/rad. In patient-in-charge mode, NEUROExos output impedance ranges from 1 N·m/rad, for 0.3 Hz motion, to 10 N·m/rad, for 3.2 Hz motion.
Recent powered (or robotic) prosthetic legs independently control different joints and time periods of the gait cycle, resulting in control parameters and switching rules that can be difficult to tune by clinicians. This challenge might be addressed by a unifying control model used by recent bipedal robots, in which virtual constraints define joint patterns as functions of a monotonic variable that continuously represents the gait cycle phase. In the first application of virtual constraints to amputee locomotion, this paper derives exact and approximate control laws for a partial feedback linearization to enforce virtual constraints on a prosthetic leg. We then encode a human-inspired invariance property called effective shape into virtual constraints for the stance period. After simulating the robustness of the partial feedback linearization to clinically meaningful conditions, we experimentally implement this control strategy on a powered transfemoral leg. We report the results of three amputee subjects walking overground and at variable cadences on a treadmill, demonstrating the clinical viability of this novel control approach.
20 March 2013 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
In this paper, we study the human locomotor adaptation to the action of a powered exoskeleton providing assistive torque at the user's hip during walking. To this end, we propose a controller that provides the user's hip with a fraction of the nominal torque profile, adapted to the specific gait features of the user from Winter's reference data . The assistive controller has been implemented on the ALEX II exoskeleton and tested on ten healthy subjects. Experimental results show that when assisted by the exoskeleton, users can reduce the muscle effort compared to free walking. Despite providing assistance only to the hip joint, both hip and ankle muscles significantly reduced their activation, indicating a clear tradeoff between hip and ankle strategy to propel walking.
1 September 2011 in Medical & Biological Engineering & Computing
Robotic leg prostheses promise to improve the mobility and quality of life of millions of individuals with lower-limb amputations by imitating the biomechanics of the missing biological leg. Unfortunately, existing powered prostheses are much heavier and bigger and have shorter battery life than conventional passive prostheses, severely limiting their clinical viability and utility in the daily life of amputees. Here, we present a robotic leg prosthesis that replicates the key biomechanical functions of the biological knee, ankle, and toe in the sagittal plane while matching the weight, size, and battery life of conventional microprocessor-controlled prostheses. The powered knee joint uses a unique torque-sensitive mechanism combining the benefits of elastic actuators with that of variable transmissions. A single actuator powers the ankle and toe joints through a compliant, underactuated mechanism. Because the biological toe dissipates energy while the biological ankle injects energy into the gait cycle, this underactuated system regenerates substantial mechanical energy and replicates the key biomechanical functions of the ankle/foot complex during walking. A compact prosthesis frame encloses all mechanical and electrical components for increased robustness and efficiency. Preclinical tests with three individuals with above-knee amputation show that the proposed robotic leg prosthesis allows for common ambulation activities with close to normative kinematics and kinetics. Using an optional passive mode, users can walk on level ground indefinitely without charging the battery, which has not been shown with any other powered or microprocessor-controlled prostheses. A prosthesis with these characteristics has the potential to improve real-world mobility in individuals with above-knee amputation.