Ursula Rohrer

Dr. Ursula Rohrer

Medical University of Graz, Graz, Steiermark, Austria
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
EKEwald Kolesnik
Ewald Kolesnik
USUniv.-Prof. Priv.-Doz. Dr.med.univ. Daniel Scherr
Univ.-Prof. Priv.-Doz. Dr.med.univ. Daniel Scherr
URUrsula Rohrer
Ursula Rohrer
MBMartin Benedikt
Martin Benedikt
MMMartin Manninger
Martin Manninger
DLDirk Von Lewinski
Dirk Von Lewinski
Sodium-glucose cotransporter 2 (SGLT2) inhibitors are gaining ground as standard therapy for heart failure with a class-I recommendation in the recently updated heart failure guidelines from the European Society of Cardiology. Different gliflozins have shown impressive beneficial effects in patients with and without diabetes mellitus type 2, especially in reducing the rates for hospitalization for heart failure, yet little is known on their antiarrhythmic properties. Atrial and ventricular arrhythmias were reported by clinical outcome trials with SGLT2 inhibitors as adverse events, and SGLT2 inhibitors seemed to reduce the rate of arrhythmias compared to placebo treatment in those trials. Mechanistical links are mainly unrevealed, since hardly any experiments investigated their impact on arrhythmias. Prospective trials are currently ongoing, but no results have been published so far. Arrhythmias are common in the heart failure population, therefore the understanding of possible interactions with SGLT2 inhibitors is crucial. This review summarizes evidence from clinical data as well as the sparse experimental data of SGLT2 inhibitors and their effects on arrhythmias.

7 April 2023 in Resuscitation Plus
Verified
Journal Article
Open access
PFPhilip Fischer
Philip Fischer
URUrsula Rohrer
Ursula Rohrer
PNPatrick Nürnberger
Patrick Nürnberger
MMMartin Manninger
Martin Manninger
DSDaniel Scherr
Daniel Scherr
EKEwald Kolesnik
Ewald Kolesnik
Out-of-hospital cardiac arrest (OHCA) is associated with poor survival rates. Factors that may enable survival include cardiopulmonary resuscitation (CPR) initiated by bystanders and early use of an automated external defibrillator (AED). This explorative simulation study was conceptualized to test the feasibility of a semi-autonomously operating drone that delivers an AED to a remote emergency location and its bystander-use. Ten paramedics and nineteen laypersons were confronted with a manikin simulating an OHCA as single bystanders within a field test located in a mountainous region between Austria and Slovenia. The scenario included a mock-call to the local emergency response center that dispatched a drone towards the caller’s GPS coordinates and supported the ongoing CPR. The outcomes were the successful delivery of the AED, the time to the first shock, hands-off times, and the overall performance of the CPR. The AED was delivered by drone and used in all 29 scenarios without serious adverse events. The flight time of the drone was in median 5:20 (range: 1:35–8:19) minutes. The paramedics delivered the first shock after a mean of 12:15 ± 2:03 min and hands-off times were 50 ± 22 s. The laypersons delivered the first shock after 14:04 ± 2:10 min and hands-off times were 2:11 ± 0:39 min. All participants felt confident in the handling of the delivered AED. The delivery and usage of an AED via a semi-autonomously flying drone in a remote region is feasible. This approach can lead to early administration of shocks.

4 August 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
URUrsula Rohrer
Ursula Rohrer
MMMartin Manninger
Martin Manninger
AZAndreas Zirlik
Andreas Zirlik
USUniv.-Prof. Priv.-Doz. Dr.med.univ. Daniel Scherr
Univ.-Prof. Priv.-Doz. Dr.med.univ. Daniel Scherr
Atrial fibrillation is the most common sustained cardiac arrhythmia in adults. It is a complex arrhythmia leading to increased morbidity and mortality requiring thorough assessment and classification to guide therapy and to assess whether to pursue rate or rhythm control therapy. To obtain rhythm control, several strategies are available with different advantages and disadvantages concerning success rate and safety. Apart from antiarrhythmic drugs, catheter ablation is a well-established invasive therapy to treat atrial fibrillation. As quality of life is a very important factor to pursue rhythm control, several studies investigated on the specific impact of catheter ablation on quality of life. Catheter ablation shows a beneficial effect on quality of life in paroxysmal and persistent atrial fibrillation independent of the timepoint and strategy of catheter ablation.

21 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
URUrsula Rohrer
Ursula Rohrer
MMMartin Manninger
Martin Manninger
AZAndreas Zirlik
Andreas Zirlik
USUniv.-Prof. Priv.-Doz. Dr.med.univ. Daniel Scherr
Univ.-Prof. Priv.-Doz. Dr.med.univ. Daniel Scherr
A wearable cardioverter-defibrillator (WCD) is a temporary treatment option for patients at high risk for sudden cardiac death (SCD) and for patients who are temporarily not candidates for an implantable cardioverter defibrillator (ICD). In addition, the need for telemedical concepts in the detection and treatment of heart failure (HF) and its arrhythmias is growing. The WCD has evolved from a shock device detecting malignant ventricular arrhythmias (VA) and treating them with shocks to a heart-failure-monitoring device that captures physical activity and cardioacoustic biomarkers as surrogate parameters for HF to help the treating physician surveil and guide the HF therapy of each individual patient. In addition to its important role in preventing SCD, the WCD could become an important tool in heart failure treatment by helping prevent HF events by detecting imminent decompensation via remote monitoring and monitoring therapy success.

Verified
Journal Article
Open access
PDF file
URUrsula Rohrer
Ursula Rohrer
MMMartin Manninger
Martin Manninger
LFLukas Fiedler
Lukas Fiedler
CSClemens Steinwender
Clemens Steinwender
RBRonald Binder
Ronald Binder
USUniv.-Prof. Priv.-Doz. Dr.med.univ. Daniel Scherr
Univ.-Prof. Priv.-Doz. Dr.med.univ. Daniel Scherr
Background: After acute myocardial infarction (AMI), patients are at risk of sudden cardiac death. The VEST trial failed to show a reduction in arrhythmic mortality in AMI patients with an LVEF ≤ 35% prescribed with a WCD, having a lower-than-expected WCD wearing compliance. Objectives: The aim was to investigate on outcomes of patients in a real-world Austrian cohort with good compliance. Methods: A retrospective analysis of all eligible Austrian WCD patients according to the VEST trial inclusion and exclusion criteria between 2010 and 2020 was performed. Results: In total, 105 Austrian patients (64 ± 11 years, 12% female; LVEF 28 ± 6%) received a WCD for a median of 69 (1; 277) days after AMI (wearing duration 23.5 (0; 24) hours/day). Within the first 90 days, 4/105 (3.8%) patients received 9 appropriate shocks (2 (1; 5) shocks). No inappropriate shocks were delivered, and 3/105 (2.9%) patients died during follow-up. Arrhythmic mortality (1.9% Austria vs. 1.6% VEST, p = 0.52), as well as all-cause mortality (2.9% vs. 3.1%, p = 0.42) was comparable in both cohorts. Conclusions: The WCD is a safe treatment option in a highly selected cohort of patients with LVEF ≤ 35% after AMI. However, despite excellent WCD wearing duration in our cohort, the arrhythmic mortality rate was not significantly different.

26 September 2024 in Drones
Verified
Journal Article
Open access
PDF file
CWChristian Wankmüller
Christian Wankmüller
URUrsula Rohrer
Ursula Rohrer
PFPhilip Fischer
Philip Fischer
PNPatrick Nürnberger
Patrick Nürnberger
EKEwald Kolesnik
Ewald Kolesnik
Delivering an automated external defibrillator (AED) to a patient suffering from out-of-hospital cardiac arrest (OHCA) as quickly as possible is a critical task. In this field, airborne drones may help to overcome long response times, especially in mountainous regions where topography and weather pose several challenges for rescuers. Drones are considered a fast option to shorten the time to the first AED shock. This study presents insights into the safety regulations, performance, reliability and public perception of this specific drone-based application. The findings are based on field tests that focused on the operational/logistical benefits and challenges of semi-autonomous drone-based AED delivery to simulated emergency sites in mountainous terrain. The generated results underline the operational and technical feasibility of the proposed system given successful AED delivery in all simulation scenarios. Several challenges remain, such as improvements in terms of the AED pick-up, mobile phone connectivity, tracking of GPS coordinates and weather resistance of the used drone are required. Overall, the study supports paving the way for future trials and real-world implementations of drones into existing emergency response systems.