Usman Qamar Shaikh

Mr. Usman Qamar Shaikh

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2023 in Heliyon
Verified
Journal Article
Open access
USUsman Qamar Shaikh
Usman Qamar Shaikh
MSMuhammad Shahzaib
Muhammad Shahzaib
SSSadia Shakil
Sadia Shakil
FBFarrukh Bhatti
Farrukh Bhatti
MSMalik Aamir Saeed
Malik Aamir Saeed
Real-time gait event detection (GED) system can be utilized for gait analysis and tracking fitness activities. GED for various types of terrains (e.g., stair-walk, uneven surfaces, etc.) is still an open research problem. This study presents an inertial sensor-based approach for real-time GED system that works for diverse terrains in an uncontrolled environment. The GED system classifies three types of terrains, i.e., flat-walk, stair-ascend and stair-descend, with an average classification accuracy of 99%. It also accurately detects various gait events, including, toe-strike, heel-rise, toe-off, and heel-strike. It is computationally efficient, implemented on a low-cost microcontroller, works in real-time and can be used in portable rehabilitation devices for use in dynamic environments.

18 March 2026 in Journal of Neural Engineering
Verified
Journal Article
Open access
USUsman Qamar Shaikh
Usman Qamar Shaikh
Anubha KalraAnubha Kalra
Anubha Kalra
ALAndrew Lowe
Andrew Lowe
Imran Khan NiaziImran Khan Niazi
Imran Khan Niazi
Objective. EEG is often contaminated by ocular (EOG) and muscle (EMG) artifacts, yet many pipelines apply uniform denoising, risking distortion of clean neural activity. We propose a two-head, single-channel regressor that estimates EOG and EMG noise-to-signal ratio (NSR, dB) from short segments and test whether it can guide selective artifact reduction, including downstream BCI decoding. Approach. Using EEGdenoiseNet clean EEG and artifact exemplars, we synthesised 2-s single-channel mixtures with known EOG/EMG NSR spanning –10 to +10 dB and trained several model families to jointly regress both NSRs. Generalisation was evaluated on an independent eyeblink dataset via agreement with regression-based ocular-reference topographies, and in two applications: (i) gating stationary wavelet blink removal on a P3 ERP dataset and (ii) gating the same denoiser on a 55-subject RSVP P300 speller dataset (FP1/FP2). Main results. A dilated temporal convolutional network (TCN) performed best (EOG: MAE ≈ 1.8 dB, R² ≈ 0.82; EMG: MAE ≈ 1.0 dB, R² ≈ 0.94) with low bias across NSR. The EOG head recovered blink topographies (median spatial correlation ≈ 0.91). On the P3 dataset, indiscriminate wavelet denoising reduced significant ERP channels, whereas TCN-guided gating preserved 22–23 of 24 while processing ~9–20% of segments. On the speller dataset, denoising all epochs reduced decoding, while selective denoising improved AUC (θ = 9 dB: ΔAUC = 0.327, p = 0.0040) while denoising 12.45 ± 9.29% of test segments. Significance. Multi-head noise regression provides interpretable, continuous ocular and muscle contamination estimates that can act as control signals for conservative, noise-aware artifact handling under constrained-lead conditions.

22 April 2026 in Sensors
Verified
Journal Article
Open access
PDF file
USUsman Qamar Shaikh
Usman Qamar Shaikh
Anubha KalraAnubha Kalra
Anubha Kalra
ALAndrew Lowe
Andrew Lowe
Imran Khan NiaziImran Khan Niazi
Imran Khan Niazi
Objective: Single-channel EEG artifact suppression often relies on signal decomposition; however, it is not always clear how much clean EEG is recoverable from a given decomposition when component weighting is ideal. We present an oracle-based benchmark that characterises this best-case recoverability across common 1-D decomposition families under controlled EOG, EMG, and mixed contamination. This work does not propose a new denoising algorithm; rather, it isolates representation capacity from component-selection heuristics by computing an upper bound on reconstruction quality. Approach: Using EEGdenoiseNet, we constructed a synthetic benchmark of 4500 single-channel 2 s segments (125 Hz; T = 250) by mixing clean EEG with ocular (EOG) and/or cranial EMG exemplars at noise-to-signal ratios (NSRs) spanning −10 to +10 dB (floor −10 dB denotes an absent modality). We evaluated variational mode decomposition (VMD), singular spectrum analysis (SSA), discrete wavelet transform (DWT), and CEEMDAN by decomposing each mixture and reconstructing the clean EEG using a bounded nonnegative linear combination of components obtained via constrained least squares (the oracle). Main results: Under this oracle benchmark, SSA achieved the lowest reconstruction error in most tested conditions, while DWT tended to rank best in milder ocular regimes; VMD performance improved, with an increased mode count at higher computational cost. CEEMDAN exhibited higher latency dominated by ensemble settings. Significance: These results should be interpreted as decomposition-level upper bounds under controlled mixtures, not field-ready denoising performance. The benchmark provides a tool with which to compare representational recoverability across decompositions and to inform the subsequent design of practical component-selection strategies.

15 October 2024
Verified
Conference Paper
Closed access
USUsman Qamar Shaikh
Usman Qamar Shaikh
Anubha KalraAnubha Kalra
Anubha Kalra
ALAndrew Lowe
Andrew Lowe
Imran Khan NiaziImran Khan Niazi
Imran Khan Niazi
Long-term electroencephalogram (EEG) monitoring requires devices that are unobtrusive, comfortable, and user-friendly. Capacitive electrodes, unlike gel or dry electrodes, do not require direct galvanic skin contact, making them ideal for extended use. This paper investigates the efficacy of capacitive electrodes for recording four biopotential channels from around-ear areas. A printed circuit board was developed and assessed through an alpha-block experiment. The posterior-ear capacitive EEG achieved a statistically significant power gain (APSD) of 2.77 dB in the alpha band and 5.84 dB at 10 Hz. Additionally, a mean absolute error (MAE) of 8.9 milliseconds was observed between heart rate variability (HRV) measurements from a capacitive superior-ear electrode and shoulder ECG. These results indicate that around-ear capacitive electrodes are suitable for multimodal biopotential applications, offering a promising solution for long-term EEG monitoring.

18 June 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
MSMuhammad Shahzaib
Muhammad Shahzaib
USUsman Qamar Shaikh
Usman Qamar Shaikh
SSSadia Shakil
Sadia Shakil
SJSobia Janghsher
Sobia Janghsher
Many people which are affected by drop foot syndrome, have to face difficulty while walking which leads to pathological gait. This type of syndrome is treated by means of an external artificial stimulation known as functional electric stimulator (FES). In this paper we are designing an online feedback control system which optimize the strength of a FES given to paretic muscle which results in correction of pathological gait of the patient in a tolerable domain. Different phases of gait are identified using inertial measurement unit (IMU) as a feedback sensor mounted on the foot. Data is collected form 8 different healthy subjects and average of collected data is used as a reference template. Different trajectories of drop foot patients are simulated (due to unavailability of patients) and corrected according to the reference template.

1 January 2026 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
USUsman Qamar Shaikh
Usman Qamar Shaikh
Anubha KalraAnubha Kalra
Anubha Kalra
ALAndrew Lowe
Andrew Lowe
Imran Khan NiaziImran Khan Niazi
Imran Khan Niazi
Single-channel electroencephalography (EEG) is attractive for wearable neurotechnology and brain-computer interface (BCI) applications, including assistive interfaces and clinical monitoring, but artifact suppression is difficult when auxiliary channels, artifact labels, or user-selected clean baseline segments are unavailable. We introduce SPAR-EEG, a self-contained framework for Selective Pass-wise Artifact Reduction in single-channel EEG. The framework applies three artifactspecific attenuation passes to each EEG epoch: a variational mode decomposition (VMD)-based pass for high-frequency electromyo-graphic (EMG) bursts, a singular spectrum analysis (SSA)-based pass for blink-like electrooculographic (EOG) transients, and an SSA-based pass for slow motion-related drift. Rather than rejecting components globally, each pass estimates artifact-dominant regions and attenuation strength directly from the input channel. SPAR-EEG was evaluated using controlled EEGdenoiseNet and PhysioBank benchmarks, pass ablations, task-locked event-related potential (ERP) preservation, runtime diagnostics, dry-electrode exercise EEG, and a downstream rapid serial visual presentation (RSVP)/P300 speller task using only FP1 and FP2. Across 26 EEGdenoiseNet input signal-to-noise ratio (SNR) levels, it obtained the largest average artifact-region SNR improvement among the tested wavelet, empirical mode decomposition (EMD), and artifact-label-guided wavelet quantile normalization (WQN) baselines for EMG, EOG, and combined EOG+EMG contamination (9.05, 8.28, and 8.00 dB, respectively). In exercise EEG, denoising reduced high-amplitude artifact burden and increased alpha and steady-state visual evoked potential (SSVEP) spectral-prominence metrics. In the P300 validation, the full SPAR-EEG sequence increased repetition-curve area under the curve (AUC) by 0.048 (Holm-adjusted p = 0.0069) and improved final Letter@15 accuracy by 7.8 percentage points. These results suggest that artifact-specific selective attenuation can provide a practical self-contained alternative for single-channel EEG denoising in low-burden and movement-prone settings.