Valentina Di Meo

Dr. Valentina Di Meo

CNR Institute for superconductors, oxides and other innovative materials and devices (SPIN), Naples, Campania, Italy
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
Valentina Di MeoValentina Di Meo
Valentina Di Meo
ACAndrea Caporale
Andrea Caporale
Alessio CrescitelliAlessio Crescitelli
Alessio Crescitelli
MJMohammed Janneh
Mohammed Janneh
EPElia Palange
Elia Palange
Emanuela EspositoEmanuela Esposito
Emanuela Esposito

29 June 2018 in Nanophotonics
Verified
Journal Article
Open access
PDF file
Valentina Di MeoValentina Di Meo
Valentina Di Meo
ACAlessio Crescitelli
Alessio Crescitelli
MMMassimo Moccia
Massimo Moccia
Annamaria SandomenicoAnnamaria Sandomenico
Annamaria Sandomenico
ACAngela M. Cusano
Angela M. Cusano
Emanuela EspositoEmanuela Esposito
Emanuela Esposito
The steadily increasing demand for accurate analysis of vitamin D level, via measurement of its best general marker, 25‐hydroxyvitamin D (25(OH)D), pushes for the development of novel automated assays capable of working at very low concentrations. Here, we propose a plasmonic biosensor of 25(OH)D3 (calcifediol) based on surface‐enhanced infrared absorption spectroscopy, which exploits the resonant coupling between plasmonic nanoantennas and vibrational excitation of small molecules. Specifically, our proposed platform features a large‐area (several mm 2 ) metasurface made of gold nanoantennas fabricated on a silicon substrate, comprising different macroregions (“pixels”) of area 500 × 500 µm 2 . In each pixel, the nanoantenna geometrical parameters are tuned so as to support localized surface plasmon resonances (and hence large field enhancements at the nanoscale) within different regions of the infrared spectrum. As a result, a single chip is capable of performing analysis from the region of functional groups to that of fingerprint. Two different designs are fabricated via electron beam lithography, functionalized with a correlated antibody for the detection of 25(OH)D3, and characterized via Fourier‐transform infrared spectroscopy. Our experiments demonstrate the capability to detect a concentration as low as 86 pmol/L, and an amount of immobilized small molecules of 25(OH)D3 monohydrate (molecular weight: 418.65 g/mol) as low as 4.31 amol over an area of 100 × 100 µm 2 .

14 December 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
GQGiuseppe Quero
Giuseppe Quero
Patrizio VaianoPatrizio Vaiano
Patrizio Vaiano
Francesco FiengaFrancesco Fienga
Francesco Fienga
MGMartino Giaquinto
Martino Giaquinto
Valentina Di MeoValentina Di Meo
Valentina Di Meo
Andrea CusanoAndrea Cusano
Andrea Cusano
In this work, we report on the first demonstration of Lab on Fiber (LOF) dosimeter for ionizing radiation monitoring at ultra-high doses. The new dosimeter consists in a metallo-dielectric resonator at sub-wavelength scale supporting localized surface plasmon resonances realized on the optical fiber (OF) tip. The resonating structure involves two gold gratings separated by a templated dielectric layer of poly(methyl methacrylate) (PMMA). Two LOF prototypes have been manufactured and exposed at the IRRAD Proton Facility at CERN in Geneva to 23 GeV protons for a total fluence of 0.67 × 10 16 protons/cm 2 , corresponding to an absorbed dose of 1.8 MGy. Experimental data demonstrated the “radiation resistance” feature of the LOF devices and a clear dependence of the reflected spectrum versus the total dose, expressed by a cumulative blue-shift of ~1.4 nm of the resonance combined with a slight increase of 0.16 dBm in the reflected spectrum. The numerical analysis carried out to correlate the experimental results with the dimensional and physical properties of the resonator, expected to be tightly connected to the absorbed dose, suggests that the main phenomenon induced by exposure to proton beam and able to explain the measured spectral behavior is the reduction of the PMMA thickness, which is also consistent with past literature in the field. Preliminary results demonstrated the potentiality of the proposed platform as dosimeter at MGy dose levels for high energy physics experiments.

11 July 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
PMpietro malara Malara
pietro malara Malara
Alessio CrescitelliAlessio Crescitelli
Alessio Crescitelli
Valentina Di MeoValentina Di Meo
Valentina Di Meo
AGAntonio Giorgini
Antonio Giorgini
SAS. Avino
S. Avino
GGG. Gagliardi
G. Gagliardi

17 June 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
NICOLA LOVECCHIONICOLA LOVECCHIO
NICOLA LOVECCHIO
Valentina Di MeoValentina Di Meo
Valentina Di Meo
Domenico CaputoDomenico Caputo
Domenico Caputo
Augusto NascettiAugusto Nascetti
Augusto Nascetti
ACAlessio Crescitelli
Alessio Crescitelli
Giampiero de CesareGiampiero de Cesare
Giampiero de Cesare
In this paper we present a device integrating on a single glass substrate a transparent heater and two resistive temperature sensors. Both heater and sensors are constituted by ITO/Au/ITO stacked film, whose thicknesses have been optimized in order to achieve at the same time good electrical conductivity (about 10 6 S/m) and high transparency degree (higher than 80%) in the visible region of the spectrum. A double-spiral design has been chosen for the heater in order to achieve a uniform temperature distribution on a large area. Indeed, this geometry ensures a temperature variation of ±1.4 °C in a 2.8 cm diameter circle. For the resistive temperature sensors, a distributed meander-shaped geometry ensures temperature sensitivity as high as 0.12 $\text{k}\pmb \Omega / ^{\circ }\text{C}$ . The proposed device shows therefore the capability to work as a large-area transparent heater introducing the possibility to perform a precise control of the substrate temperature.

10 June 2020 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
NICOLA LOVECCHIONICOLA LOVECCHIO
NICOLA LOVECCHIO
Domenico CaputoDomenico Caputo
Domenico Caputo
FCFrancesca Costantini
Francesca Costantini
Valentina Di MeoValentina Di Meo
Valentina Di Meo
Augusto NascettiAugusto Nascetti
Augusto Nascetti
Giampiero de CesareGiampiero de Cesare
Giampiero de Cesare
This article investigates the stability of hydrogenated amorphous silicon (a-Si:H) p-i-n junctions employed as temperature sensors in lab-on-chip (LoC) applications. The devices have been tested under forward current injection and different temperatures (from room temperature up to 90 °C) in order to reproduce the practical operating conditions. Two sets of devices with different diborane concentrations in the p-doped layer have been investigated as a case study. For both sets, a temperature-drift error of 0.05 °C/h and a sensitivity around 3 mV/°C in the range between 30 °C and 90 °C have been achieved. These results demonstrate the device suitability as a thin-film temperature sensor integrated into LoC systems that implement thermal treatment of the biological samples as, for example, DNA amplification.