Bart Maurice Vande Vannet

Prof. Dr. Bart Maurice Vande Vannet

Odontology, Department of Orthodontics, University of Lorraine, Nancy, Grand Est, France
orcid
Professor of Orthodontics PUPH Head of Department of Orthod...

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2018 in European Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
AGAnnelore De Grauwe
Annelore De Grauwe
IAIrem Ayaz
Irem Ayaz
SSSohaib Shujaat
Sohaib Shujaat
SDSimon Dimitrov
Simon Dimitrov
LGLogan Gbadegbegnon
Logan Gbadegbegnon
RJReinhilde Jacobs
Reinhilde Jacobs
Summary: Background: Taking into account radiation doses, safety, and protection, we highlighted the features in which cone-beam computed tomography (CBCT) can offer an advantage compared to the conventional two-dimensional imaging in paediatric dentistry before orthodontic treatment.Objective: The aim of this article was to conduct a systematic review to assess the diagnostic efficacy of CBCT in the paediatric population at a pre-orthodontic phase.Search methods: MEDLINE via PubMed was searched to identify all peer-reviewed articles potentially relevant to the review until 1 July 2018. Relevant publications were selected by two reviewers independently.Selection criteria: The literature selection for this systematic review was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement and was based on predetermined inclusion criteria.Data collection and analysis: Data were collected on overall study characteristics and examination characteristics of the selected studies. Methodological quality of the selected studies was evaluated. Original studies were assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool. Thereafter, levels of evidence were obtained according to Grading of Recommendations Assessment, Development and Evaluation criteria.Results: As a result of the QUADAS assessment, a total of 37 articles were included in the protocol. Following a proper protocol, CBCT was regarded as a reliable tool for assessment and management of impacted canine and root fracture. It provided a better evaluation of normal and pathological condylar shape and volume. CBCT was a superior choice for pre-surgical diagnostic applications in cleft lip and/or palate over a medical computed tomography based on its lower radiation exposure, shorter investigation time, and low purchase costs.Conclusions: CBCT is justified only in those cases where conventional radiography fails to provide a correct diagnosis of pathology. Therefore, it cannot be regarded as a standard method of diagnosis. CBCT imaging may also be justified when it positively affects treatment options or provides treatment optimization.Registration: None.Conflict of interest: None to declare.

14 September 2005 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
KAKarlien Asscherickx
Karlien Asscherickx
Bart Maurice Vande VannetBart Maurice Vande Vannet
Bart Maurice Vande Vannet
HWHeiner Wehrbein
Heiner Wehrbein
MSMehran Moradi Sabzevar
Mehran Moradi Sabzevar

16 October 2009 in European Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
MTMichel P. E. Tacken
Michel P. E. Tacken
JCJan Cosyn
Jan Cosyn
PWPeter De Wilde
Peter De Wilde
JAJohan Aerts
Johan Aerts
EGElke Govaerts
Elke Govaerts
Bart Maurice Vande VannetBart Maurice Vande Vannet
Bart Maurice Vande Vannet
The objective of this study was to compare glass fibre reinforced (GFR) with multistranded bonded orthodontic retainers in terms of success rate and periodontal implications. A 2 year parallel study was conducted of 184 patients scheduled to receive bonded retainers in the upper and lower anterior segments. In three centres, the patients (mean age 14 years; 90 males and 94 females) were sequentially assigned to receive GFR retainers containing 500 unidirectional glass fibres (GFR500), 1000 unidirectional glass fibres (GFR1000), or multistranded retainers (gold standard). Retainer failures and periodontal conditions were monitored every 6 months. In a control group of 90 subjects without retainers, periodontal conditions were examined (negative control). Of the 274 recruited patients, 15 dropped out during the 2 year study period. Kaplan–Meier plots were drawn to assess survival of the different retainers. The Mantel–Cox log-rank test was used to identify significant differences in survival functions among the groups. Repeated measures analysis of variance and appropriate post hoc tests were adopted to evaluate periodontal conditions over time. GFR retainers showed unacceptably high failure rates in comparison with multistranded retainers (51 versus 12 per cent). The most significant periodontal conditions were found in patients with GFR retainers with no significant differences between the GFR500 and the GFR1000 group for any parameter at any time point. Subjects without retainers showed significantly lower levels of gingival inflammation and plaque accumulation when compared with patients in any retainer group. Multistranded retainers should remain the gold standard for orthodontic retention, although periodontal complications are common. The use of GFR retainers should be discouraged in daily practice.

1 October 2007 in European Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
Bart Maurice Vande VannetBart Maurice Vande Vannet
Bart Maurice Vande Vannet
MSMehran Moradi Sabzevar
Mehran Moradi Sabzevar
HWHeinrich Wehrbein
Heinrich Wehrbein
KAKarlien Asscherickx
Karlien Asscherickx
Mini-implants and miniscrews are commonly used in orthodontics to provide additional temporary intraoral anchorage. Partial osseointegration represents a distinct advantage in orthodontic applications, allowing effective anchorage to be combined with easy insertion and removal. This article reports the histomorphometric findings of the osseointegration of bracket screw bone anchors (BSBAs). In an experimental animal study, four BSBAs were inserted in the alveolar process of the lower jaw in each of five male beagle dogs, aged 6.5 months from the same mother. Eleven screws were lost during the study, nine of them due to lack of primary stability. One screw was removed at the end of the examination period for evaluation of ease of removal. After 6 months, histological evaluation of the eight remaining screws was performed to evaluate the extent of osseointegration. All eight screws showed partial osseointegration (mean 74.48 per cent, standard deviation ± 15.33 per cent). The amount of osseointegration was independent of loading time and location (anterior or posterior), as tested with an independent samples t-test (P > 0.05). Analysis of the data indicated that small titanium screws were able to function as rigid osseous anchors against an orthodontic load of 200 cN for 6, 12, 18, or 24 weeks after a minimal healing period or no healing period. These findings show that miniscrews, used for temporary anchorage in orthodontics, partially osseointegrate.

16 July 2008 in European Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
KAK. Asscherickx
K. Asscherickx
Bart Maurice Vande VannetBart Maurice Vande Vannet
Bart Maurice Vande Vannet
HWH. Wehrbein
H. Wehrbein
MSM. M. Sabzevar
M. M. Sabzevar
The purpose of this study was to evaluate, histologically, root contact, proximity to a root, and proximity to marginal bone level as possible risk factors for the failure of mini-screws when inserted between neighbouring teeth. Twenty mini-screws were inserted into the mandible of five beagle dogs. Each dog received two bracket screw bone anchors in each lower quadrant, between the roots of the second and third, and third and fourth premolars. Every six weeks, apical radiographs were taken and vital stains were administered. Twenty-five weeks after insertion of the screws, the dogs were sacrificed and specimens prepared for histological evaluation. The distance between the screw and the roots and between the screw and the marginal ridge level (MRL) were measured on the histological slides. The presence or absence of root contact was evaluated histologically on serial sections. The number of screws was too small to allow for sound statistical analysis of the factors under investigation. During the evaluation period, 11 screws were lost. Six screws were in contact with a tooth root and five of these were lost. In five sites, the distance between the screw and the tooth was less than 1.0 mm, but only one of these screws was lost. The distance between the screw and the marginal bone level was less than 1.0 mm for nine screws and seven of these were lost. The results of this limited study suggest that root contact and marginal position might be major risk factors for screw failure.

1 March 2016 in American Journal of Orthodontics and Dentofacial Orthopedics
Verified
Journal Article
Closed access
KAKarlien Asscherickx
Karlien Asscherickx
EGElke Govaerts
Elke Govaerts
JAJohan Aerts
Johan Aerts
Bart Maurice Vande VannetBart Maurice Vande Vannet
Bart Maurice Vande Vannet