Miniature high-bandwidth accelerometers on the anterior neck surface are used in laboratory and ambulatory settings to obtain vocal function measures. This study compared the widely applied L1–L2 measure (historically, H1–H2)—the difference between the log-magnitude of the first and second harmonics—computed from the glottal airflow waveform with L1–L2 derived from the raw neck-surface acceleration signal in 79 vocally healthy female speakers. Results showed a significant correlation (r = 0.72) between L1–L2 values estimated from both airflow and accelerometer signals, suggesting that raw accelerometer-based estimates of L1–L2 may be interpreted as reflecting glottal physiological parameters and voice quality attributes during phonation.
12 December 2019 in IEEE Journal of Selected Topics in Signal Processing
Subglottal air pressure plays a major role in voice production and is a primary factor in controlling voice onset, offset, sound pressure level, glottal airflow, vocal fold collision pressures, and variations in fundamental frequency. Previous work has shown promise for the estimation of subglottal pressure from an unobtrusive miniature accelerometer sensor attached to the anterior base of the neck during typical modal voice production across multiple pitch and vowel contexts. This study expands on that work to incorporate additional accelerometer-based measures of vocal function to compensate for non-modal phonation characteristics and achieve an improved estimation of subglottal pressure. Subjects with normal voices repeated /p/-vowel syllable strings from loud-to-soft levels in multiple vowel contexts (/a/, /i/, and /u/), pitch conditions (comfortable, lower than comfortable, higher than comfortable), and voice quality types (modal, breathy, strained, and rough). Subject-specific, stepwise regression models were constructed using root-mean-square (RMS) values of the accelerometer signal alone (baseline condition) and in combination with cepstral peak prominence, fundamental frequency, and glottal airflow measures derived using subglottal impedance-based inverse filtering. Five-fold cross-validation assessed the robustness of model performance using the root-mean-square error metric for each regression model. Each cross-validation fold exhibited up to a 25% decrease in prediction error when the model incorporated multi-dimensional aspects of the accelerometer signal compared with RMS-only models. Improved estimation of subglottal pressure for non-modal phonation was thus achievable, lending to future studies of subglottal pressure estimation in patients with voice disorders and in ambulatory voice recordings.
15 September 2020 in Journal of Speech, Language, and Hearing Research
Purpose: The purpose of this study was to determine whether estimates of glottal aerodynamic measures based on neck-surface vibration are comparable to those previously obtained using oral airflow and air pressure signals (Espinoza et al., 2017) in terms of discriminating patients with phonotraumatic and nonphonotraumatic vocal hyperfunction (PVH and NPVH) from vocally healthy controls. Method: Consecutive /pae/ syllables at comfortable and loud level were produced by 16 women with PVH (organic vocal fold lesions), 16 women with NPVH (primary muscle tension dysphonia), and 32 vocally healthy women who were each matched to a patient according to age and occupation. Subglottal impedance-based inverse filtering of the anterior neck-surface accelerometer (ACC) signal yielded estimates of peak-to-peak glottal airflow, open quotient, and maximum flow declination rate. Average subglottal pressure and microphone-based sound pressure level (SPL) were also estimated from the ACC signal using subject-specific linear regression models. The ACC-based measures of glottal aerodynamics were normalized for SPL and statistically compared between each patient and matched-control group. Results: Patients with PVH and NPVH exhibited lower SPL-normalized glottal aerodynamics values than their respective control subjects ( p values ranging from < .01 to .07) with very large effect sizes (1.04–2.16), regardless of loudness condition or measurement method (i.e., ACC-based values maintained discriminatory power). Conclusions: The results of this study demonstrate that ACC-based estimates of most glottal aerodynamic measures are comparable to those previously obtained from oral airflow and air pressure (Espinoza et al., 2017) in terms of differentiating between hyperfunctional (PVH and NPVH) and normal vocal function. ACC-based estimates of glottal aerodynamic measures may be used to assess vocal function during continuous speech and enables this assessment of daily voice use during ambulatory monitoring to provide better insight into the pathophysiological mechanisms associated with vocal hyperfunction.
The development of trauma-induced lesions of the vocal folds (VFs) has been linked to a high collision pressure on the VF surface. However, there are no direct methods for the clinical assessment of VF collision, thus limiting the objective assessment of these disorders. In this study, we develop a video processing technique to directly quantify the mechanical impact of the VFs using solely laryngeal kinematic data. The technique is based on an edge tracking framework that estimates the kinematic sequence of each VF edge with a Kalman filter approach and a Hertzian impact model to predict the contact force during the collision. The proposed formulation overcomes several limitations of prior efforts since it uses a more relevant VF contact geometry, it does not require calibrated physical dimensions, it is normalized by the tissue properties, and it applies a correction factor for using a superior view only. The proposed approach is validated against numerical models, silicone vocal fold models, and prior studies. A case study with high-speed videoendoscopy recordings provides initial insights between the sound pressure level and contact pressure. Thus, the proposed method has a high potential in clinical practice and could also be adapted to operate with laryngeal stroboscopic systems.
17 August 2022 in Journal of Speech, Language, and Hearing Research
Purpose: This exploratory study aims to investigate variations in voice production in the presence of background noise (Lombard effect) in individuals with nonphonotraumatic vocal hyperfunction (NPVH) and individuals with typical voices using acoustic, aerodynamic, and vocal fold vibratory measures of phonatory function. Method: Nineteen participants with NPVH and 19 participants with typical voices produced simple vocal tasks in three sequential background conditions: baseline (in quiet), Lombard (in noise), and recovery (5 min after removing the noise). The Lombard condition consisted of speech-shaped noise at 80 dB SPL through audiometric headphones. Acoustic measures from a microphone, glottal aerodynamic parameters estimated from the oral airflow measured with a circumferentially vented pneumotachograph mask, and vocal fold vibratory parameters from high-speed videoendoscopy were analyzed. Results: During the Lombard condition, both groups exhibited a decrease in open quotient and increases in sound pressure level, peak-to-peak glottal airflow, maximum flow declination rate, and subglottal pressure. During the recovery condition, the acoustic and aerodynamic measures of individuals with typical voices returned to those of the baseline condition; however, recovery measures for individuals with NPVH did not return to baseline values. Conclusions: As expected, individuals with NPVH and participants with typical voices exhibited a Lombard effect in the presence of elevated background noise levels. During the recovery condition, individuals with NPVH did not return to their baseline state, pointing to a persistence of the Lombard effect after noise removal. This behavior could be related to disruptions in laryngeal motor control and may play a role in the etiology of NPVH. Supplemental Material: https://doi.org/10.23641/asha.20415600