In this paper, the 4E assessment (Energetic, Exergetic, Exergoeconomic and Exergoenvironmental) of a low-temperature ORC activated by two different alternatives is presented. The first alternative (S1) contemplates the activation of the ORC through the recovery of waste heat from a flash–binary geothermal power plant. The second alternative (S2) contemplates the activation of the ORC using direct heat from a geothermal well. For both alternatives, the energetic and exergetic models were established. At the same time, the economic and environmental impact models were developed. Finally, based on the combination of the exergy concepts and the economic and ecological indicators, the exergoeconomic and exergoenvironmental performances of the ORC were obtained. The results show higher economic, exergoeconomic and exergoenvironmental profitability for S1. Besides, for the alternative S1, the ORC cycle has an acceptable economic profitability for a net power of 358.4 kW at a temperature of 110 °C, while for S2, this profitability starts being attractive for a power 2.65 times greater than S1 and with a temperature higher than 135 °C. In conclusion, the above represents an area of opportunity and a considerable advantage for the implementation of the ORC in the recovery of waste heat from flash–binary geothermal power plants.
Natural gas stations require a preheating stage to prevent the formation of hydrates inside of them provoked by a sudden decompression process of the natural gas. The preheating process has been investigated to improve efficiency and to reduce costs as well. This work studies the behavior of a natural gas decompression station with a first-stage preheating process using a vortex tube and a geothermal heat exchanger, followed by a second stage involving a water bath heater (heating vat). An energetic, exergetic, and exergoeconomic study has been carried out based on a mathematical model and the theory of exergetic cost, obtaining key thermodynamic and thermoeconomic variables, including exergy flows and equipment costs. A heat flow of 26.41 kW was obtained in the geothermal preheating stage; meanwhile, a 60.43 kW heat flow was obtained in the heating vat. The results showed a saving in station fuel using only 2.046% of the natural gas in the system at the second preheating stage. Also, the system was optimized, obtaining a 15.73% reduction in the decompressed natural gas cost. These findings show the possibility of implementing these systems in zones with many geothermal resources to reach a constant, profitable natural gas supply in areas where a pipeline network does not exist.