We report a fiber-structured hybrid nanogenerator wearable device fabricated on a single polyethylene terephthalate (PET) textile cylindrical substrate. The device can be described as a capacitor with inner and outer carbon-black-dispersed poly dimethyl siloxane (PDMS:Carbon black) electrodes, and zinc oxide and polyvinylidene fluoride (PVDF) as the dielectric medium between the electrodes. The compositional analysis in terms of X-ray diffraction, Fourier transform infrared spectroscopy, and scanning electron microscopy of the synthesized ZnO/PVDF has been measured and analyzed. The combined effect of triboelectricity between PDMS:Carbon black and PVDF, and piezoelectricity in a ZnO/PVDF hybrid, was investigated. Current–voltage characteristics were observed with varying load from 0–20 g, and resistance was observed to be decreased with load. Compared to earlier reports, there was a significant enhancement in voltage (≈5.1 V) and current (≈92.5 nA) at 10 g. Due to the introduction of interfacial polarization between PVDF and ZnO, the piezoelectric properties and pressure sensitivity of the hybrid ZnO/PVDF is enhanced. The hysterical behavior in the device’s response while measuring voltage and current with varying time shows the signature of the triboelectric effect between PVDF and ZnO, as well as PDMS:Carbon black and ZnO/PVDF layers. Reduction of triboelectric behavior was confirmed with increasing relaxation time. Because of the enhancement in piezoelectricity, fiber-structured nanogenerator (FNG) ZnO/PVDF proved to a potential candidate to be used for wearable computing devices, such as smart watches and sports bracelets.
1 October 2019 in Sensors and Actuators A: Physical
We report the fabrication of single-phase polycrystalline Pb0.85Bi0.10(Zr0.52Ti0.48)O3 (PBiZT) ceramic which shows large polarization, i.e., ∼40 μC cm−2 and piezoelectric coefficients ∼130 pC N−1 and giant linear change in capacitive reactance and dielectric properties with increasing and decreasing pressure in the range of 1 kHz to 5 MHz. Nearly 70% change in dielectric constant and 56% change in capacitive reactance were obtained in the pressure range of 20–200 MPa, which makes it suitable for applications as a capacitive pressure sensor/gauge. The sensitivity of the device is calculated as 0.66 MPa−1 and 18.2 MPa−1 at 1 MHz and 5 MHz, respectively, which is the highest ever reported value so far for any bulk polycrystalline ceramic. The compressive stress of the device was tested according to the standard test method as a function of linear and volumetric strain, which yields the Young's modulus, Bulk modulus, and Poisson's ratio of the device. These values were further utilized to calculate actual stress in the sample and energy density using ANSYS software, which indicates at least four orders smaller pressure in the sample compared to the applied pressure.