VINICIUS RIZZO MARQUES

Dr. VINICIUS RIZZO MARQUES

Restorative Dentistry, SUNY University at Buffalo, Buffalo, New York, USA
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2022 in Journal of Dentistry
Verified
Journal Article
Open access
GCGulce Cakmak
Gulce Cakmak
VMVINICIUS RIZZO MARQUES
VINICIUS RIZZO MARQUES
MDMustafa Borga Donmez
Mustafa Borga Donmez
WLWei-En Lu
Wei-En Lu
SASamir Abou-Ayash
Samir Abou-Ayash
BYBurak Yilmaz
Burak Yilmaz
To investigate the effect of 3-dimensional (3D) analysis software and operator on the measured deviations in implant scans. A combined healing abutment-scan body (CHA-SB) system was digitized with an industrial scanner (ATOS Core 80) to generate a master standard tessellation language file (MRM-STL) and an intraoral scanner (TRIOS 3) to generate 9 test-scan STL files, which were transferred into metrology-grade (Geomagic Control X, GX and GOM Inspect, GM) and nonmetrology-grade (Medit Link, ML) software for deviation analysis. Test-scan STLs were superimposed over MRM-STL and 2 planes passing through the center of the SB were generated. Distance deviations at 8 points on these planes were analyzed by two different operators with similar level of experience. Data were analyzed with analysis of variance and F tests (α=.05). Only model 1 (P=.049) analyzed by operator 2 showed significant differences among tested software, and the highest deviations were measured with GM (P≤.037). However, the difference in values measured with GX and ML was nonsignificant (P=.91). Operator correlation was high (ICC≥.712, P≤.011), except for models 1 (GM, ICC=-.335, P=.813), 2 (GM, ICC=.025, P=.468 and ML, ICC=-.013, P=.507), 6 (GM, ICC=-.085, P=.583), and 8 (GM, ICC=-.386, P=.85). The measured deviations in implant scans in all models, except for one, were similar among the tested software, regardless of the operator. The inter-rater reliability of operators while using tested 3D analysis software was overall high. When observed, low inter-rater reliability was mostly with only one of the metrology grade software. Nonmetrology-grade 3D analysis software may be a suitable alternative to metrology-grade software to measure the deviations in digital implant scan body scans. When GOM metrology-software is used, measured deviations in implant scan body scans may vary more across operators.

1 July 2021 in Journal of Dentistry
Verified
Journal Article
Open access
BYBurak Yilmaz
Burak Yilmaz
DGDiogo Gouveia
Diogo Gouveia
VMVINICIUS RIZZO MARQUES
VINICIUS RIZZO MARQUES
EDEmre Diker
Emre Diker
MSMartin Schimmel
Martin Schimmel
SASamir Abou-Ayash
Samir Abou-Ayash
To compare the accuracy of polyvinylsiloxane (PVS) impressions and intraoral scans when a healing abutment-scanpeg system (HASP) or a conventional scanbody (CSB) was used on a single implant. A maxillary model with an implant (4.0 × 11 mm) (Neoss) and a CSB or an HASP (Neoss) was scanned by using a laboratory scanner (Ceramill Map 600; Amann Girrbach) (reference scans) and an intraoral scanner (Trios 3) (n = 10). PVS open-tray impressions were also made and stone casts of the model with a CSB were digitized with the laboratory scanner. Intraoral scanner and cast scans were superimposed to their reference scans. On superimposed scans, points were selected on HASP and CSB to calculate distance deviations (at points 1-4) and angular deviations (at points 5 and 6 on CSB and PVS, and 5-8 on HASP) between scans (trueness), and their variation (precision). The deviation data was analyzed with ANOVA and pairwise comparisons (trueness) with Tukey's adjustment, and F-tests (precision). At point 1, PVS had lower trueness than CSB (difference in means (DIMs) = 0.184 mm, p = 0.006) and HASP (DIMs = 0.122 mm, p = 0.042). At point 3, CSB had higher trueness than HASP (DIMs = 0.134 mm, p = 0.001). Angular deviations with PVS were higher than with CSB (DIMs = 0.6°, p = 0.013) and HASP (DIMs = 0.7°, p = 0.005). CSB had higher precision than PVS (p < 0.05). HASP had higher precision than PVS for distance (Point 1)(p < 0.001) and angular deviations (p < 0.05). Deviation differences within the HASP parts were not significant. The accuracy of intraoral scans and PVS impressions of an implant was similar. The combined healing abutment-scanpeg system and the conventional scanbody can be recommended for scans of anterior single implants with the intraoral scanner used.

1 August 2015 in Journal of Applied Oral Science
Verified
Journal Article
Open access
PDF file
KNKarin Neppelenbroek
Karin Neppelenbroek
EKEduardo Kuroishi
Eduardo Kuroishi
JHJuliana Hotta
Juliana Hotta
VMVINICIUS RIZZO MARQUES
VINICIUS RIZZO MARQUES
EMEduardo Moffa
Eduardo Moffa
VUVanessa Migliorini Urban
Vanessa Migliorini Urban
Key words: Coloring agents; Hardness; Surface properties; Artificial tooth

1 June 2021 in Journal of Dentistry
Verified
Journal Article
Open access
BYBurak Yilmaz
Burak Yilmaz
VMVINICIUS RIZZO MARQUES
VINICIUS RIZZO MARQUES
XGXiaohan Guo
Xiaohan Guo
DGDiogo Gouveia
Diogo Gouveia
SASamir Abou-Ayash
Samir Abou-Ayash
To investigate the effect of scanned area on the accuracy and scan time of intraoral scans of an anterior implant. Three operators experienced in intraoral scanning (at least 2-year experience) performed partial and complete-arch scans (n = 10) of a dentate resin model with an implant at left central incisor site by using an intraoral scanner (Trios3; 3Shape, Copenhagen, Denmark). Each partial- or complete-arch scan was superimposed to a reference scan from a laboratory scanner (Ceramill Map 600; Amann Girrbach AG). Mean distance (selected 7 points) and angular (mesiodistal and buccolingual) scanbody deviations in test scans (trueness) and their variance (precision) were calculated. Linear-regressions (trueness), two-sided F-tests with a Bonferroni correction (precision), and multiple linear regressions (scan time), with the operator as a covariate were applied (alpha = .05). Interactions were found between the scanned area and the operator for their effect on trueness of all points and angles, except for point 6 at implant-abutment connection in mesiodistal plane (p < .05). No significant difference was found between the precision of partial and complete-arch scans for all operators (p > .05). Partial-arch scan times were significantly shorter, overall, and for each operator (p < .001). No significant effect of scan time was found on the trueness of partial- and complete-arch scans (p > .05). Partial and complete-arch scans of anterior single implants with an intraoral scanner resulted in similar accuracies, and were not influenced by the operator or the scan time. Scan times of partial-arch scans were significantly shorter. Partial-arch scans can be used for the fabrication of monolithic anterior single implant crowns because the scans can be completed in shorter times without compromising the accuracy.

1 January 2009 in Journal of Applied Oral Science
Verified
Journal Article
Open access
CBCarolina Silveira Barbosa
Carolina Silveira Barbosa
GBGabriel Salles Barbério
Gabriel Salles Barbério
VMVINICIUS RIZZO MARQUES
VINICIUS RIZZO MARQUES
VBVitor de Oliveira Baldo
Vitor de Oliveira Baldo
MBMarília Afonso Rabelo Buzalaf
Marília Afonso Rabelo Buzalaf
AMAna Carolina Magalhães
Ana Carolina Magalhães
The rate of bariatric surgery has significantly risen in the past decade as an increasing prevalence of extreme obesity can be observed. Although bariatric surgery is an effective therapeutic modality for extreme obesity, it is associated with risk factors affecting also oral health. Based on an overview of the current literature, this paper presents a summary of dental manifestations in bariatric patients. Bariatric surgeries are associated with an increased risk for gastro-esophageal reflux which in turn might account for the higher amount of carious and erosive lesions observed in bariatric patients. As a result, also dentin hypersensitivity might be observed more frequently. The current data indicate that recommended postsurgical meal patterns and gastric reflux might increase the risk for dental lesions, particularly in the presence of other risk factors, such as consumption of sweet-tasting foods and acidic beverages. Further research is needed to evaluate the correlation of bariatric surgery and the development of dental diseases.

Verified
Journal Article
Open access
PDF file
VMVINICIUS RIZZO MARQUES
VINICIUS RIZZO MARQUES
GCGulce Cakmak
Gulce Cakmak
HYHakan Yilmaz
Hakan Yilmaz
SASamir Abou-Ayash
Samir Abou-Ayash
MDMustafa Borga Donmez
Mustafa Borga Donmez
BYBurak Yilmaz
Burak Yilmaz
Studies have shown the effect of the operator and scanned areas on the accuracy of single implant scans. However, the knowledge on the scan accuracy of the remaining dental arch during single implant scans, which may affect the occlusion, is limited. The aim of this study was to investigate the effect of scanned areas and the operator on the scan accuracy of a dentate arch while scanning a single implant. A dentate model with an anterior implant was digitized with a laboratory scanner (reference scan). Three operators with similar experience performed 10 complete- and 10 partial-arch scans (left 2nd molar to right canine) with an intraoral scanner (TRIOS 3), and these scans were superimposed over the reference. The accuracy was analyzed at 22 points in complete-arch and at 16 points in partial-arch scans on 2nd molars and incisors. Data were evaluated with 2-way ANOVA and Tukey HSD tests (α = 0.05). The trueness of the total scanned area was higher in partial- than in complete-arch scans (p < 0.001). The trueness and precision of the scans were higher in the anterior site compared with the posterior in complete- (trueness: p ≤ 0.022, precision: p ≤ 0.003) and partial-arch (trueness: p ≤ 0.016, precision: p ≤ 0.016) scans of each operator and when the operator scan data were pooled. The complete-arch scan’s precision was not influenced by the operator (p ≥ 0.029), whereas the partial-arch scans of operator 1 and 2 were significantly different (p = 0.036). Trueness was higher in partial- compared with complete-arch scans, but their precision was similar. Accuracy was higher in the anterior site regardless of the scan being a partial- or a complete-arch. The operator’s effect on the accuracy of partial- and complete-arch scans was small.
1