Gulce Cakmak

Dr. Gulce Cakmak


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 October 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GCGulce Cakmak
Gulce Cakmak
ACAlfonso Rodriguez Cuellar
Alfonso Rodriguez Cuellar
MDMustafa Borga Donmez
Mustafa Borga Donmez
MSMartin Schimmel
Martin Schimmel
SASamir Abou-Ayash
Samir Abou-Ayash
BYBurak Yilmaz
Burak Yilmaz
The information in the literature on the effect of printing layer thickness on interim 3D-printed crowns is limited. In the present study, the effect of layer thickness on the trueness and margin quality of 3D-printed composite resin crowns was investigated and compared with milled crowns. The crowns were printed in 3 different layer thicknesses (20, 50, and 100 μm) by using a hybrid resin based on acrylic esters with inorganic microfillers or milled from polymethylmethacrylate (PMMA) discs and digitized with an intraoral scanner (test scans). The compare tool of the 3D analysis software was used to superimpose the test scans and the computer-aided design file by using the manual alignment tool and to virtually separate the surfaces. Deviations at different surfaces on crowns were calculated by using root mean square (RMS). Margin quality of crowns was examined under a stereomicroscope and graded. The data were evaluated with one-way ANOVA and Tukey HSD tests. The layer thickness affected the trueness and margin quality of 3D-printed interim crowns. Milled crowns had higher trueness on intaglio and intaglio occlusal surfaces than 100 μm-layer thickness crowns. Milled crowns had the highest margin quality, while 20 μm and 100 μm layer thickness printed crowns had the lowest. The quality varied depending on the location of the margin.

18 October 2023 in Journal of Prosthodontics
Verified
Journal Article
Open access
MGMiguel Gómez-Polo
Miguel Gómez-Polo
MDMustafa Borga Donmez
Mustafa Borga Donmez
GCGulce Cakmak
Gulce Cakmak
BYBurak Yilmaz
Burak Yilmaz
MRMarta Revilla-León
Marta Revilla-León
Purpose: To evaluate the influence of implant scan body (ISB) design (height, diameter, geometry, material, and retention system) on the accuracy of digital implant scans.Material and Methods: A literature search was completed in five databases: PubMed/Medline, Scopus, Embase, World of Science, and Cochrane. A manual search was also conducted. Studies reporting the evaluation of ISB design on the accuracy of digital scans obtained by using IOSs were included. Two investigators evaluated the studies independently by applying the Joanna Briggs Institute critical appraisal. A third examiner was consulted to resolve any lack of consensus. Articles were classified based on the ISB features of height, geometry, material, and retention system.Results: Twenty articles were included. Among the reviewed studies, 11 investigations analyzed the influence of different ISB geometries, 1 study assessed the impact of ISB diameter, 4 studies investigated the effect of ISB splinting, 2 articles evaluated ISB height, and 2 studies focused on the effect of ISB material on scan accuracy. In addition, 8 studies involved ISBs fabricated with different materials (1‐ and 2‐piece polyetheretherketone and 1‐piece titanium ISBs), and all of the reviewed articles tested screw‐retained ISBs, except for 3 in vitro studies.Conclusions: The findings did not enable concrete conclusions regarding the optimal ISB design, whether there is a relationship between IOS technology and a specific ISB design, or the clinical condition that maximizes intraoral scanning accuracy. Research efforts are needed to identify the optimal ISB design and its possible relationship with the IOS selected for acquiring intraoral digital implant scans.

8 July 2020 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
PDF file
GCGulce Cakmak
Gulce Cakmak
HYHakan Yilmaz
Hakan Yilmaz
ATAlejandro Treviño
Alejandro Treviño
AKAli Murat Kökat
Ali Murat Kökat
BYBurak Yilmaz
Burak Yilmaz

18 July 2023 in Journal of Prosthodontics
Verified
Journal Article
Open access
GCGulce Cakmak
Gulce Cakmak
AOAlice Lisa Oosterveen‐Rüegsegger
Alice Lisa Oosterveen‐Rüegsegger
CACanan Akay
Canan Akay
MSMartin Schimmel
Martin Schimmel
BYBurak Yilmaz
Burak Yilmaz
MDMustafa Borga Donmez
Mustafa Borga Donmez
Purpose: To evaluate how different polishing techniques and coffee thermal cycling affect the surface roughness and stainability of additively and subtractively manufactured resins used for definitive prostheses.Materials and Methods: Two additively manufactured composite resins (Crowntec, CT and VarseoSmile Crown Plus, VS) and a subtractively manufactured resin nanoceramic (Cerasmart, CS) were used to fabricate 90 rectangular‐shaped specimens (14 × 12 × 1 mm) (n = 30). After baseline surface roughness (Ra) measurements, specimens were divided into three groups based on the polishing technique; conventional polishing with a 2‐stage polishing kit (CP) and surface sealant application (Optiglaze, OG or Vita Akzent LC, VA) (n = 10). After polishing, specimens were subjected to 10,000 cycles of coffee thermal cycling. Ra and color coordinate measurements were performed after polishing and after coffee thermal cycling. Color difference (ΔE00) was calculated. Scanning electron microscope images were taken at each time interval. Kruskal–Wallis or 1‐way analysis of variance (ANOVA) were used to evaluate Ra of materials within each polishing‐time interval pair and different polishing techniques within each material‐time interval pair, while Friedman or repeated measures ANOVA were used to evaluate Ra at different time intervals within each material‐polishing pair. ΔE00 was assessed with 2‐way ANOVA (α = 0.05).Results: Other than VA‐after polishing (p = 0.055), tested materials had significantly different Ra within each polishing‐time interval pair (p ≤ 0.038). When Ra differences among different polishing techniques within each material‐time interval pair were considered, CS had differences after coffee thermal cycling, CT had differences before polishing and after coffee thermal cycling, and VS had differences within each time interval (p ≤ 0.038). When Ra differences among different time intervals within each material‐polishing pair were considered, significant differences were observed among all pairs (p ≤ 0.016), except for CS‐VA (p = 0.695) and VS‐VA (p = 0.300). ΔE00 values were affected by material and polishing technique interaction (p = 0.007).Conclusions: Ra of CS was similar to or lower than the Ra of other materials, regardless of the time interval or polishing technique. CP mostly led to lower Ra than other polishing techniques, whereas VA resulted in a high Ra regardless of the material‐time interval pair. Polishing reduced the Ra, while coffee thermal cycling was found to have a small effect. Among tested material‐polishing pairs, only CS‐VA had moderately unacceptable color change when previously reported threshold values were considered.

1 September 2021 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
SASevda Atalay
Sevda Atalay
GCGulce Cakmak
Gulce Cakmak
MFManrique Fonseca
Manrique Fonseca
MSMartin Schimmel
Martin Schimmel
BYBurak Yilmaz
Burak Yilmaz
To evaluate the effect of thermocycling on the water contact angle (WCA), surface roughness (SR), and microhardness (MH) of different CAD-CAM PMMA denture base materials after different surface treatments (conventional laboratory polishing, polishing kit, or surface sealant). Disk-shaped specimens (10 × 2 mm) of 3 different CAD-CAM PMMAs, AvaDent (AV); Merz M-PM (M-PM); Polident (Poli), and a conventional heat-polymerized PMMA (Vynacron) (CV) (n=21) were divided into 3 different surface treatment groups (n=7): conventional laboratory polishing (CLP), polishing with acrylic resin polisher kit (PK), and a surface sealant (Palaseal) (SSC). Stereomicroscopic images were taken both before and after thermocycling. WCA, SR, and MH of all specimens were measured before and after thermocycling and compared by using a 2-way ANOVA (α=0.05). After thermocycling, WCA significantly increased for CLP- or PK -applied (P<.001) specimens of all materials and SSC-applied M-PM (P=.002), SR significantly increased for CLP-applied M-PM (P=.027) and PK-applied Poli (P=.041), and MH significantly decreased for CLP- or PK-applied AV (P = .001, P < .001, respectively), CV (P=.033, P=.023, respectively), and M-PM (P=.003, P=.001, respectively), SSC-applied M-PM (P<.001), and CLP-applied Poli (P<.001). Stereomicroscopic images revealed rougher surfaces for PK-applied specimens. After thermocycling, surface treatment had a significant effect on water contact angle and surface roughness. CLP or PK application resulted in hydrophobic surfaces compared with before thermocycling. CLP or SSC application on CAD-CAM PMMAs resulted in smoother surfaces. Thermocycling lowered the microhardness of all PMMAs, and the decrease was significant in CLP- or PK-applied PMMAs, except for PK-applied Poli.

16 September 2022 in Materials
Verified
Journal Article
Open access
PDF file
GCGulce Cakmak
Gulce Cakmak
PMPedro Molinero-Mourelle
Pedro Molinero-Mourelle
MPMarcella Silva De Paula
Marcella Silva De Paula
CACanan Akay
Canan Akay
ACAlfonso Rodriguez Cuellar
Alfonso Rodriguez Cuellar
BYBurak Yilmaz
Burak Yilmaz
Three-dimensional (3D) printing is increasingly used to fabricate denture base materials. However, information on the effect of simulated brushing and thermocycling on the surface roughness and color stability of 3D-printed denture base materials is lacking. The aim of this study was to evaluate the effect of brushing and thermocycling on the surface roughness and color stability of 3D-printed denture base materials and to compare with those of milled and heat-polymerized denture base resins. Disk-shaped specimens (Ø 10 mm × 2 mm) were prepared from 4 different denture base resins (NextDent Denture 3D+ (ND); Denturetec (SC); Polident d.o.o (PD); Promolux (CNV)) (n = 10). Surface roughness (Ra) values were measured before and after polishing with a profilometer. Initial color coordinates were measured by using a spectrophotometer after polishing. Specimens were then consecutively subjected to simulated brushing (10,000 cycles), thermocycling (10,000 cycles), and brushing (10,000 cycles) again. Ra and color coordinates were measured after each interval. Color differences (ΔE00) between each interval were calculated and these values were further evaluated considering previously reported perceptibility (1.72 units) and acceptability (4.08 units) thresholds. Data were analyzed with Friedman, Kruskal–Wallis, and Mann–Whitney U tests (α = 0.05). Ra (p ≥ 0.051) and ΔE00 (p ≥ 0.061) values among different time intervals within each material were similar. Within each time interval, significant differences in Ra (p ≤ 0.002) and ΔE00 values (p ≤ 0.001) were observed among materials. Polishing, brushing, and thermocycling resulted in acceptable surface roughness for all materials that were either similar to or below 0.2 µm. Color of ND printed resin was affected by brushing and thermocycling. All materials had acceptable color stability when reported thresholds are considered.