Holographic tomography (HT) is an advanced label-free optical microscopic imaging method used for biological studies. HT uses digital holographic microscopy to record the complex amplitudes of a biological sample as digital holograms and then numerically reconstruct the sample’s refractive index (RI) distribution in three dimensions. The RI values are a key parameter for label-free bio-examination, which correlate with metabolic activities and spatiotemporal distribution of biophysical parameters of cells and their internal organelles, tissues, and small-scale biological objects. This article provides insight on this rapidly growing HT field of research and its applications in biology. We present a review summary of the HT principle and highlight recent technical advancement in HT and its applications.
Quantitative Phase Imaging (QPI) provides unique means for the imaging of biological or technical microstructures, merging beneficial features identified with microscopy, interferometry, holography, and numerical computations. This roadmap article reviews several digital holography-based QPI approaches developed by prominent research groups. It also briefly discusses the present and future perspectives of 2D and 3D QPI research based on digital holographic microscopy, holographic tomography, and their applications.
Digital holographic microtomography is a promising technique for three-dimensional (3D) measurement of the refractive index (RI) profiles of biological specimens. Measurement of the RI distribution of a free-floating single living cell with an isotropic superresolution had not previously been accomplished. To the best of our knowledge, this is the first study focusing on the development of an integrated dual-tomographic (IDT) imaging system for RI measurement of an unlabelled free-floating single living cell with an isotropic superresolution by combining the spatial frequencies of full-angle specimen rotation with those of beam rotation. A novel ‘UFO’ (unidentified flying object) like shaped coherent transfer function is obtained. The IDT imaging system does not require any complex image-processing algorithm for 3D reconstruction. The working principle was successfully demonstrated and a 3D RI profile of a single living cell, Candida rugosa, was obtained with an isotropic superresolution. This technology is expected to set a benchmark for free-floating single live sample measurements without labeling or any special sample preparations for the experiments.
Indirect-imaging methods involve at least two steps, namely optical recording and computational reconstruction. The optical-recording process uses an optical modulator that transforms the light from the object into a typical intensity distribution. This distribution is numerically processed to reconstruct the object’s image corresponding to different spatial and spectral dimensions. There have been numerous optical-modulation functions and reconstruction methods developed in the past few years for different applications. In most cases, a compatible pair of the optical-modulation function and reconstruction method gives optimal performance. A new reconstruction method, termed nonlinear reconstruction (NLR), was developed in 2017 to reconstruct the object image in the case of optical-scattering modulators. Over the years, it has been revealed that the NLR can reconstruct an object’s image modulated by an axicons, bifocal lenses and even exotic spiral diffractive elements, which generate deterministic optical fields. Apparently, NLR seems to be a universal reconstruction method for indirect imaging. In this review, the performance of NLR isinvestigated for many deterministic and stochastic optical fields. Simulation and experimental results for different cases are presented and discussed.
In this study, a novel adaptive wavefront correction (AWC) technique is implemented on a compactly developed structured illumination holographic tomography (SI-HT) system. We propose a mechanical movement-free compact scanning architecture for SI-HT systems with AWC, implemented by designing and displaying a series of computer-generated holograms (CGH) composed of blazed grating with phase Fresnel lens on a phase-only spatial light modulator (SLM). In the proposed SI-HT, the aberrations of the optical system are sensed by digital holography and are used to design the CGH-based AWC to compensate the phase aberrations of the tomographic imaging system. The proposed method was validated using a standard Siemens star target, its potential application was demonstrated using a live candida rugosa sample, and its label-free three-dimensional refractive index profile was generated at its subcellular level. The experimental results obtained reveal the ability of the proposed method to enhance the imaging performance in both lateral and axial directions.
In this study, we introduce what we believe is a novel holographic optical element called a chiral square Fresnel zone plate (CSFZP). The chirality is imposed on a square Fresnel zone plate (SFZP) using a nonclassical technique by rotating the half-period zones relative to one another. The rotation of the half-period zones, in turn, twists the side lobes of the diffraction pattern without altering the focusing properties inherent to a SFZP. As a consequence, the beam profile is hybrid, consisting of a strong central Gaussian focal spot with gradient force similar to that generated by a lens and twisted side lobes with orbital angular momentum. The optical fields at the focal plane were calculated and found to possess a whirlpool-phase profile and a twisted intensity profile. Analysis of the field variation along the direction of propagation revealed a spiraling phase and amplitude distribution. Poynting vector plot of the fields revealed the presence of angular momentum in the regions of chiral side lobes. The phase of the CSFZPs were displayed on a phase-only reflective spatial light modulator and illuminated using a laser. The intensity patterns recorded in the experiment match the calculated ones, with a strong central focal spot and twisted side lobes. The beam pattern was implemented in an optical trapping experiment and was found to possess particle trapping capabilities.