Vajira Lasantha Thambawita

Dr. Vajira Lasantha Thambawita

HOST, Simula Metropolitan Center for Digital Engineering, Oslo, Norway
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2020 in Scientific Data
Verified
Journal Article
Open access
PDF file
HBHanna Borgli
Hanna Borgli
Vajira Lasantha ThambawitaVajira Lasantha Thambawita
Vajira Lasantha Thambawita
PSPia H. Smedsrud
Pia H. Smedsrud
SHSteven Hicks
Steven Hicks
DJDebesh Jha
Debesh Jha
TLThomas de Lange
Thomas de Lange
Artificial intelligence is currently a hot topic in medicine. However, medical data is often sparse and hard to obtain due to legal restrictions and lack of medical personnel for the cumbersome and tedious process to manually label training data. These constraints make it difficult to develop systems for automatic analysis, like detecting disease or other lesions. In this respect, this article presents HyperKvasir, the largest image and video dataset of the gastrointestinal tract available today. The data is collected during real gastro- and colonoscopy examinations at Bærum Hospital in Norway and partly labeled by experienced gastrointestinal endoscopists. The dataset contains 110,079 images and 374 videos, and represents anatomical landmarks as well as pathological and normal findings. The total number of images and video frames together is around 1 million. Initial experiments demonstrate the potential benefits of artificial intelligence-based computer-assisted diagnosis systems. The HyperKvasir dataset can play a valuable role in developing better algorithms and computer-assisted examination systems not only for gastro- and colonoscopy, but also for other fields in medicine.

27 May 2021 in Scientific Data
Verified
Journal Article
Open access
PDF file
PSPia H. Smedsrud
Pia H. Smedsrud
Vajira Lasantha ThambawitaVajira Lasantha Thambawita
Vajira Lasantha Thambawita
SHSteven A. Hicks
Steven A. Hicks
HGHenrik Gjestang
Henrik Gjestang
ONOda Olsen Nedrejord
Oda Olsen Nedrejord
Pål HalvorsenPål Halvorsen
Pål Halvorsen
Artificial intelligence (AI) is predicted to have profound effects on the future of video capsule endoscopy (VCE) technology. The potential lies in improving anomaly detection while reducing manual labour. Existing work demonstrates the promising benefits of AI-based computer-assisted diagnosis systems for VCE. They also show great potential for improvements to achieve even better results. Also, medical data is often sparse and unavailable to the research community, and qualified medical personnel rarely have time for the tedious labelling work. We present Kvasir-Capsule, a large VCE dataset collected from examinations at a Norwegian Hospital. Kvasir-Capsule consists of 117 videos which can be used to extract a total of 4,741,504 image frames. We have labelled and medically verified 47,238 frames with a bounding box around findings from 14 different classes. In addition to these labelled images, there are 4,694,266 unlabelled frames included in the dataset. The Kvasir-Capsule dataset can play a valuable role in developing better algorithms in order to reach true potential of VCE technology.

2 May 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Vajira Lasantha ThambawitaVajira Lasantha Thambawita
Vajira Lasantha Thambawita
PSPegah Salehi
Pegah Salehi
SSSajad Amouei Sheshkal
Sajad Amouei Sheshkal
SHSteven A. Hicks
Steven A. Hicks
HHHugo L. Hammer
Hugo L. Hammer
Michael Alexander RieglerMichael Alexander Riegler
Michael Alexander Riegler
Analyzing medical data to find abnormalities is a time-consuming and costly task, particularly for rare abnormalities, requiring tremendous efforts from medical experts. Therefore, artificial intelligence has become a popular tool for the automatic processing of medical data, acting as a supportive tool for doctors. However, the machine learning models used to build these tools are highly dependent on the data used to train them. Large amounts of data can be difficult to obtain in medicine due to privacy reasons, expensive and time-consuming annotations, and a general lack of data samples for infrequent lesions. In this study, we present a novel synthetic data generation pipeline, calledSinGAN-Seg, to produce synthetic medical images with corresponding masks using a single training image. Our method is different from the traditional generative adversarial networks (GANs) because our model needs only a single image and the corresponding ground truth to train. We also show that the synthetic data generation pipeline can be used to produce alternative artificial segmentation datasets with corresponding ground truth masks when real datasets are not allowed to share. The pipeline is evaluated using qualitative and quantitative comparisons between real data and synthetic data to show that the style transfer technique used in our pipeline significantly improves the quality of the generated data and our method is better than other state-of-the-art GANs to prepare synthetic images when the size of training datasets are limited. By training UNet++ using both real data and the synthetic data generated from the SinGAN-Seg pipeline, we show that the models trained on synthetic data have very close performances to those trained on real data when both datasets have a considerable amount of training data. In contrast, we show that synthetic data generated from the SinGAN-Seg pipeline improves the performance of segmentation models when training datasets do not have a considerable amount of data. All experiments were performed using an open dataset and the code is publicly available on GitHub.

24 November 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
Vajira Lasantha ThambawitaVajira Lasantha Thambawita
Vajira Lasantha Thambawita
Inga StrümkeInga Strümke
Inga Strümke
SHSteven A. Hicks
Steven A. Hicks
Pål HalvorsenPål Halvorsen
Pål Halvorsen
SPSravanthi Parasa
Sravanthi Parasa
Michael Alexander RieglerMichael Alexander Riegler
Michael Alexander Riegler
Recent trials have evaluated the efficacy of deep convolutional neural network (CNN)-based AI systems to improve lesion detection and characterization in endoscopy. Impressive results are achieved, but many medical studies use a very small image resolution to save computing resources at the cost of losing details. Today, no conventions between resolution and performance exist, and monitoring the performance of various CNN architectures as a function of image resolution provides insights into how subtleties of different lesions on endoscopy affect performance. This can help set standards for image or video characteristics for future CNN-based models in gastrointestinal (GI) endoscopy. This study examines the performance of CNNs on the HyperKvasir dataset, consisting of 10,662 images from 23 different findings. We evaluate two CNN models for endoscopic image classification under quality distortions with image resolutions ranging from 32 × 32 to 512 × 512 pixels. The performance is evaluated using two-fold cross-validation and F1-score, maximum Matthews correlation coefficient (MCC), precision, and sensitivity as metrics. Increased performance was observed with higher image resolution for all findings in the dataset. MCC was achieved at image resolutions between 512 × 512 pixels for classification for the entire dataset after including all subclasses. The highest performance was observed with an MCC value of 0.9002 when the models were trained on the highest resolution and tested on the same resolution. Different resolutions and their effect on CNNs are explored. We show that image resolution has a clear influence on the performance which calls for standards in the field in the future.

9 November 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Vajira Lasantha ThambawitaVajira Lasantha Thambawita
Vajira Lasantha Thambawita
JIJonas L. Isaksen
Jonas L. Isaksen
SHSteven A. Hicks
Steven A. Hicks
JGJonas Ghouse
Jonas Ghouse
GAGustav Ahlberg
Gustav Ahlberg
JKJørgen Kanters
Jørgen Kanters
Recent global developments underscore the prominent role big data have in modern medical science. But privacy issues constitute a prevalent problem for collecting and sharing data between researchers. However, synthetic data generated to represent real data carrying similar information and distribution may alleviate the privacy issue. In this study, we present generative adversarial networks (GANs) capable of generating realistic synthetic DeepFake 10-s 12-lead electrocardiograms (ECGs). We have developed and compared two methods, named WaveGAN* and Pulse2Pulse. We trained the GANs with 7,233 real normal ECGs to produce 121,977 DeepFake normal ECGs. By verifying the ECGs using a commercial ECG interpretation program (MUSE 12SL, GE Healthcare), we demonstrate that the Pulse2Pulse GAN was superior to the WaveGAN* to produce realistic ECGs. ECG intervals and amplitudes were similar between the DeepFake and real ECGs. Although these synthetic ECGs mimic the dataset used for creation, the ECGs are not linked to any individuals and may thus be used freely. The synthetic dataset will be available as open access for researchers at OSF.io and the DeepFake generator available at the Python Package Index (PyPI) for generating synthetic ECGs. In conclusion, we were able to generate realistic synthetic ECGs using generative adversarial neural networks on normal ECGs from two population studies, thereby addressing the relevant privacy issues in medical datasets.

14 November 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SHSteven A. Hicks
Steven A. Hicks
JAJorunn M. Andersen
Jorunn M. Andersen
OWOliwia Witczak
Oliwia Witczak
Vajira Lasantha ThambawitaVajira Lasantha Thambawita
Vajira Lasantha Thambawita
PHPål Halvorsen
Pål Halvorsen
MRMichael A. Riegler
Michael A. Riegler
Methods for automatic analysis of clinical data are usually targeted towards a specific modality and do not make use of all relevant data available. In the field of male human reproduction, clinical and biological data are not used to its fullest potential. Manual evaluation of a semen sample using a microscope is time-consuming and requires extensive training. Furthermore, the validity of manual semen analysis has been questioned due to limited reproducibility, and often high inter-personnel variation. The existing computer-aided sperm analyzer systems are not recommended for routine clinical use due to methodological challenges caused by the consistency of the semen sample. Thus, there is a need for an improved methodology. We use modern and classical machine learning techniques together with a dataset consisting of 85 videos of human semen samples and related participant data to automatically predict sperm motility. Used techniques include simple linear regression and more sophisticated methods using convolutional neural networks. Our results indicate that sperm motility prediction based on deep learning using sperm motility videos is rapid to perform and consistent. Adding participant data did not improve the algorithms performance. In conclusion, machine learning-based automatic analysis may become a valuable tool in male infertility investigation and research.