Introduction: In orthodontics, determining the parameters of tooth size and dental arch and conducting Bolton analysis is crucial for diagnosis, treatment planning, and patient outcomes. This study evaluates the accuracy and reliability of measuring dental-arch dimensions on digital models created using the CEREC Primescan intraoral scanner, compared to measurements taken from plaster models. Methods: The study included two types of dental models (plaster and intraoral scan) from sixty-three subjects. Impressions were taken to create plaster models, and the subjects’ mouths were scanned with the CEREC Primescan system (Dentsply Sirona, Charlotte, NC) to create digital models. Intra-arch measurements included tooth heights and widths, overjet, and overbite. The arch width and depth were examined at the first permanent upper or lower molar. The paired t-test and Bland–Altman plot were used to determine the accuracy, while intra-rater and inter-rater correlation coefficient values were calculated to assess the reliability of measurements from the intraoral scan compared to those from the plaster model. Results: For tooth heights, there was a statistically significant difference in only one measurement (tooth 34) between the plaster and digital models, with an average difference of 0.01 mm. For tooth widths, there was a statistically significant difference in only one measurement (tooth 15) with an average difference of 0.03 mm. The Bland–Altman plots of almost all of measurements of tooth heights and widths showed that differences between the two models were within the limits of agreement. The inter- and intra-rater correlation coefficient values for measurements on the digital model were found to be statistically insignificant. Conclusion: Measuring dental dimensions on digital models obtained through the Primescan intraoral digital system yielded similar results to those obtained from plaster models and showed excellent reliability, indicating its potential application in clinical practice.
Background: This study aims to compare treatment time and patient satisfaction between digital and conventional impression techniques in single-tooth implant prosthetics. Materials and Methods: A controlled study was conducted on 22 patients with single-tooth loss in the posterior arch who underwent implant replacement. Impressions were taken using both conventional techniques (polyvinyl siloxane) and digital methods (3Shape Trios 3 Move scanner). Results: The digital impression technique significantly reduced treatment time compared to the conventional method. The total procedure time and individual steps in the digital process were notably shorter than those in the conventional process (p < 0.001). Patients who underwent digital impressions reported not only significantly higher satisfaction and comfort levels but also less pain, unpleasant taste, and level of nausea (p < 0.001). Conclusions: Digital impressions can be superior in reducing treatment time and improving patient satisfaction compared to conventional methods, highlighting their advantages in single-tooth implant prosthetics. However, further research, involving different digital systems and clinical evaluations, is required to fully validate these advantages.
Purposes: In orthodontics, determining the parameters of tooth size, dental arch, and conducting Bolton analysis is crucial for diagnosis, treatment planning, and patient outcomes. This study evaluates the accuracy and reliability of measuring dental arch dimensions on digital models created using the CEREC Primescan intraoral scanner, compared to measurements taken from plaster models. Materials and Methods: The study included two types of dental models (plaster and intraoral scan) from 63 subjects. Impressions were taken to create plaster models, and the subjects' mouths were scanned with the CEREC Primescan system (Dentsply Sirona, Charlotte, NC) to create digital models. Intra-arch measurements included tooth heights and widths, overjet, and overbite. The arch width and depth were examined at the first permanent upper or lower molar. The paired t-test and Bland-Altman plot were used to determine the accurary, while intra-rater and inter-rater correlation coefficient values were calculated to assess reliability of measurements from the intraoral scan compared to those from the plaster model. Results: For tooth heights, there was a statistically significant difference in only one measurement (tooth 34) between the plaster and digital models, with an average difference of 0.01 mm. For tooth widths, there was a statistically significant difference in only one measurement (tooth 15) with an average difference of 0.03 mm. The Bland-Altman plots of alomost all of measurements of tooth heights and widths showed that differences between the two models were within the limits of agreement. The inter- and intra-rater correlation coefficient values for measurements on the digital model were found to be statistically insignificant. Conclusion: Measuring dental dimensions on digital models obtained through the Primescan intraoral digital system yielded similar results to those obtained from plaster models and showed excellent reliability, indicating its potential application in clinical practice.
Adequate peri-implant soft tissue is essential for functional and aesthetic success. Autologous grafts are effective but limited by morbidity. This study assessed a porcine-derived acellular dermal matrix (PADM) for anterior maxillary soft-tissue augmentation. 31 patients with implants in the anterior maxilla underwent PADM grafting. Keratinized gingival thickness, width (KGW), zenith–incisal edge distance, and shrinkage rate were measured at baseline (T0), immediate postoperative (T1), 1 month (T2), and 3 months (T3). Aesthetic outcomes were assessed with the pink aesthetic score, and pain with a numeric rating scale. Data were analyzed using Friedman and Wilcoxon signed-rank tests. keratinized gingival thickness increased from 0.69 ± 0.30 mm at T0 to 2.40 ± 0.63 mm at T1 ( P < .001), decreasing to 1.55 ± 0.41 mm at T3 but remaining above baseline. KGW remained stable. Zenith–incisal edge distance showed significant differences among time points (χ² = 31.31, P < .001). Shrinkage rates were 16.1% (T1–T2) and 33.1% (T2–T3). Pink aesthetic score improved from 5.6 ± 2.1 to 6.8 ± 2.2 at 3 months ( P < .05). Numeric rating scale pain declined from 2.7 ± 1.2 immediately post-op to 0.4 ± 0.5 after 1 week ( P < .001). No complications occurred. PADM is a clinically effective and esthetically favorable option for peri-implant soft-tissue augmentation in the anterior maxilla. It offers acceptable long-term tissue stability and excellent patient tolerance. However, postoperative tissue shrinkage remains a concern, warranting further investigation in controlled comparative studies.
Background: This study aims to compare treatment time and patient satisfaction between digital and conventional impression techniques in single-tooth implant prosthetics. Materials and Methods: A controlled study was conducted on 22 patients with single-tooth loss in the posterior arch who underwent implant replacement. Impressions were taken using both conventional techniques (polyvinyl siloxane) and digital methods (3Shape Trios 3 Move scanner). Results: The digital impression technique significantly reduced treatment time compared to the conventional method. The total procedure time and individual steps in the digital process were notably shorter than those in the conventional process (p < 0.001). Patients who underwent digital impressions reported significantly not only higher satisfaction and comfort levels, but also less pain, unpleasant taste and level of nausea (p < 0.001). Conclusion: Digital impressions demonstrate superior efficiency in reducing treatment time and improving patient satisfaction compared to conventional methods, highlighting their advantages in single-tooth implant prosthetics.
Đặt vấn đề: Quét trong miệng là giai đoạn đầu tiên và rất quan trọng trong quy trình làm việc số hóa. Có nhiều hệ thống quét trong miệng đã được thương mại hoá nhưng chỉ một số hệ thống đã được đánh giá trên lâm sàng như hệ thống Lava COS, iTero, TRIOS. Mục tiêu nghiên cứu: Đánh giá độ chính xác và khả năng lặp lại khi đo đạc các kích thước của cung răng trên mẫu hàm số hoá từ việc quét trực tiếp trong miệng với hệ thống CEREC Primescan. (Primescan). Đối tượng và phương pháp nghiên cứu: Nghiên cứu in vitro với thiết kế nghiên cứu mô tả cắt ngang trên 60 cặp mẫu hàm thạch cao được lấy dấu truyền thống và 60 cặp mẫu hàm số hóa được quét bằng Primescan trên tình nguyện viên tương ứng. Kết quả: Kích thước gần-xa của răng dưới sau hai lần đo có sự khác nhau có ý nghĩa thống kê giữa hai phương pháp đo ở các răng số 32, 33, 36, 45, 46 trong lần đo thứ nhất và răng số 43 trong lần đo thứ hai. Không nhận thấy sự khác biệt giữa hai nhóm nghiên cứu khi đo chiều cao thân răng ở lần thứ hai. Độ cắn chìa và độ cắn phủ được đo bằng hai phương pháp cho thấy sự khác biệt đáng kể giữa hai lần đo. Không tìm thấy bất kỳ sự chênh lệch nào trên biến tỉ số tổng thể (phân tích Bolton) khi so sánh độ chính xác của hai phương pháp đo hay ở hai lần đo. Xét về khả năng lặp lại khi đo trên mẫu hàm số, chỉ có độ cắn chìa sau hai lần đo cho thấy sự khác biệt có ý nghĩa thống kê. Kết luận: So với đo đạc kích thước cung răng trên mẫu hàm thạch cao thì đo đạc trên mẫu hàm số hóa từ Primescan cho nhiều kết quả chính xác, có thể ứng dụng vào thực tiễn lâm sàng.