Nathan Wood

Mr. Nathan Wood

Department of Biology, Texas A&M University, College Station, Texas, USA

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
TRTaieba Tuba Rahman
Taieba Tuba Rahman
NWNathan Wood
Nathan Wood
Yeasir Mohammad AkibYeasir Mohammad Akib
Yeasir Mohammad Akib
HQHongmin Qin
Hongmin Qin
ZJ PeiZJ Pei
ZJ Pei
This paper reports an experimental study on the compatibility of human bronchial epithelial (HBE) cells in a collagen–alginate bioink. The compatibility was assessed using the culture well method with three bioink compositions prepared from a 10% alginate solution and neutralized TeloCol-10 mg/mL collagen stock solution. Cell viability, quantified by (live cell count—dead cell count)/live cell count within the HBE cell-laden hydrogel, was evaluated using the live/dead assay method from Day 0 to Day 6. Experimental results demonstrated that the collagen–alginate 4:1 bioink composition exhibited the highest cell viability on Day 6 (85%), outperforming the collagen–alginate 1:4 bioink composition and the alginate bioink composition, which showed cell viability of 75% and 45%, respectively. Additionally, the live cell count was highest for the collagen–alginate 4:1 bioink composition on Day 0, a trend that persisted through Days 1 to 6, underscoring its superior performance in maintaining cell viability and promoting cell proliferation. These findings show that the compatibility of HBE cells with the collagen–alginate 4:1 bioink composition was higher compared with the other two bioink compositions.

10 January 2025 in Biomimetics
Verified
Journal Article
Open access
PDF file
NWNathan Wood
Nathan Wood
EDEsther Isabelle Doria
Esther Isabelle Doria
TRTaieba Tuba Rahman
Taieba Tuba Rahman
WLWanhe Li
Wanhe Li
ZJ PeiZJ Pei
ZJ Pei
HQHongmin Qin
Hongmin Qin
In this preliminary study, the long-term effects of calcium chloride crosslinking concentration on viability of 16HBE14o- human bronchial epithelial cells embedded in alginate-extracellular matrix (ECM) or alginate–methylcellulose–ECM hydrogels have been investigated. There is currently a limited understanding regarding the effects of crosslinking solution concentration on lung epithelial cells embedded in hydrogel. Furthermore, the effects of calcium chloride concentration in crosslinking solutions on other cell types have not been reported regarding whether the addition of viscosity and stiffness tuning agents such as methylcellulose will alter the responses of cells to changes in calcium chloride concentration in crosslinking solutions. While there were no significant effects of calcium chloride concentration on cell viability in alginate–ECM hydrogels, there is a decrease in cell viability in alginate–methylcellulose–ECM hydrogels crosslinked with 300 mM calcium chloride crosslinking solution. These findings have implications in the maintenance of 16HBE14o- 3D cultures with respect to the gelation of alginate with high concentrations of ionic crosslinking solution.

12 January 2024 in Journal of Manufacturing Science and Engineering
Verified
Journal Article
Closed access
PDF file
TRTaieba Tuba Rahman
Taieba Tuba Rahman
NWNathan Wood
Nathan Wood
Al Mazedur RahmanAl Mazedur Rahman
Al Mazedur Rahman
ZJ PeiZJ Pei
ZJ Pei
HQHongmin Qin
Hongmin Qin
Bioprinting using algae cells has many potential applications including tissue engineering, environmental engineering, contaminant removal from water, and establishing space habitats. In extrusion-based bioprinting, bioink needs to be crosslinked after being extruded from the nozzle for printed constructs to first achieve and then maintain adequate shape fidelity. Crosslinking methods used in reported studies on algae-contained bioinks include both photo-crosslinking and ionic crosslinking. This paper reports a preliminary study where the coaxial nozzle-based in situ ionic crosslinking method was used in bioprinting of algae cells without additional crosslinking of printed samples for the first time. In comparison with photo-crosslinking, in situ ionic crosslinking can minimize bioink preparation time and complexity, eliminate cells’ exposure to ultraviolet radiation, and reduce the number of post-printing steps. In this preliminary study, the bioink was an alginate solution containing algae (Chlorella vulgaris) cells, and the crosslinking solution was a calcium chloride solution. The coaxial nozzle had two nozzles: inner and outer nozzles. In printing, the bioink was delivered through the outer nozzle while the crosslinking solution was delivered through the inner nozzle. The shape of the printed samples was a square block with dimensions of 30 × 30 × 10 mm. It was observed that, 9 days after printing, the algae cells grew within the printed samples, and the samples could keep their shapes relatively well. Many knowledge gaps exist regarding the effects of input variables in bioprinting of algae cells using this method. This paper discusses future research directions to fill these knowledge gaps.

28 November 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
TRTaieba Tuba Rahman
Taieba Tuba Rahman
NWNathan Wood
Nathan Wood
ZJ PeiZJ Pei
ZJ Pei
HQHongmin Qin
Hongmin Qin
This paper reports an experimental study on the effects of extreme temperature on human bronchial epithelial (HBE) cells encapsulated in 3D printed samples. Well plates of the 3D printed samples were exposed to three levels of temperature (37 °C, 45 °C, and 55 °C, respectively) for a duration of 10 min. Cells’ responses, specifically cell viability and oxidative stress, were quantified using Hoechst 33342, Sytox, and Mitosox stains, with intensity measurements obtained via a plate reader. In addition, cell viability was assessed through microscopic imaging of the 3D printed samples. Experimental results demonstrated that the temperature increase from 37 °C to 55 °C significantly reduced nuclear integrity as observed through Hoechst 33342 intensity, while increased Sytox intensity reflected a higher degree of cell death. Furthermore, cells exposed to 45 °C and 55 °C exhibited decreased cell viability and elevated mitochondrial oxidative stress. These findings offer valuable insights into the effects of extreme temperature on HBE cells, establishing a foundation for future research into how respiratory tissues respond to thermal stress. This research can potentially advance the knowledge regarding effects of heat exposure on the respiratory system.

8 May 2025 in Biomimetics
Verified
Journal Article
Open access
PDF file
TRTaieba Tuba Rahman
Taieba Tuba Rahman
NWNathan Wood
Nathan Wood
ZJ PeiZJ Pei
ZJ Pei
HQHongmin Qin
Hongmin Qin
PMPadmini Mohan
Padmini Mohan
This study investigates how different levels of extrusion pressure during 3D printing affect the cell viability of human bronchial epithelial (HBE) cells embedded in printed samples. In this study, samples were printed at three levels of extrusion pressure. The cell viability was assessed through live/dead staining via microscopic imaging. The results show that increasing the extrusion pressure from 50 to 100 kPa led to a higher degree of cell death. These results demonstrate how the extrusion pressure affects the viability of HBE cells and provide a basis for future studies on pressure-induced responses in respiratory tissues.

29 September 2024 in Biomimetics
Verified
Journal Article
Open access
PDF file
TRTaieba Tuba Rahman
Taieba Tuba Rahman
Al Mazedur RahmanAl Mazedur Rahman
Al Mazedur Rahman
ZJ PeiZJ Pei
ZJ Pei
NWNathan Wood
Nathan Wood
HQHongmin Qin
Hongmin Qin
This study systematically investigates the effects of the coaxial nozzle’s inner nozzle diameter on the strength and gelation of filaments produced via extrusion-based 3D printing with in situ ionic crosslinking. In this system, bioink (sodium alginate solution) was extruded through the outer nozzle, and the ionic crosslinking solution (calcium chloride solution) was extruded through the inner nozzle. The outer nozzle diameter was fixed at 2.16 mm, and the inner nozzle diameter was varied among 1.19, 0.84, and 0.584 mm. The results indicate that, as the inner nozzle diameter decreased, filament strength decreased, and filament gelation became poorer. These findings highlight the importance of optimizing inner nozzle diameter for improved filament strength and gelation in extrusion-based 3D printing with in situ ionic crosslinking.