Xiaoting Zhang

Dr. Xiaoting Zhang

Institut National des Sciences Appliquées de Lyon, Lyon, Auvergne-Rhône-Alpes, France

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
XZXiaoting Zhang
Xiaoting Zhang
José VillafuerteJosé Villafuerte
José Villafuerte
Vincent ConsonniVincent Consonni
Vincent Consonni
JCJean-Fabien Capsal"
Jean-Fabien Capsal"
PCPierre-Jean COTTINET
Pierre-Jean COTTINET
MLMinh-Quyen LE
Minh-Quyen LE
Due to the outstanding coupling between piezoelectric and semiconducting properties of zinc oxide nanowires, ZnO NW-based structures have been demonstrating promising potential with respect to their applicability in piezoelectric, piezotronic and piezo-phototronic devices. Particularly considering their biocompatibility and biosafety for applications regarding implantable medical detection, this paper proposed a new concept of piezoelectric composite, i.e., one consisting of vertically aligned ZnO NW arrays and an insulating polymer matrix. First, the finite element method (FEM) was employed to drive optimization strategies through adjustment of the key parameters such as Young’s modules and the dielectric constant of the dielectric constituents, together with the density and dimension of nanowire (NW) itself. Second, to investigate the functionality of each individual layer of composite, different designed structures were fabricated and characterized in terms of electrical and piezoelectric properties. Next, experimental and simulation tests were performed, indicating that the decreasing thickness of the top poly(methyl methacrylate) layer (PMMA) can substantially enhance the piezoelectric sensitivity of the ZnO NW composite. Besides the further benefit of no polarization being needed, our material has a comparable charge coefficient (d33) with respect to other lead-free alternatives (e.g., BaTiO3), confirming the high sensing abilities of the developed structure based on vertically aligned ZnO NW arrays. Finally, a time-varying model combining piezoelectricity and electric circuit modules was investigated in detail, giving rise to an estimation of the d33 coefficient for ZnO NWs. Based on this study, the developed material is revealed to be highly promising in medical applications, particularly regarding the FFR technique, where coronary pressure can be measured through a piezoelectric sensor.

14 April 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
XZXiaoting Zhang
Xiaoting Zhang
José VillafuerteJosé Villafuerte
José Villafuerte
Vincent ConsonniVincent Consonni
Vincent Consonni
ESEirini Sarigiannidou
Eirini Sarigiannidou
JCJean-Fabien Capsal"
Jean-Fabien Capsal"
MLMinh-Quyen LE
Minh-Quyen LE
Piezoelectric ZnO-based composites have been explored as a flexible and compact sensor for the implantable biomedical systems used in cardio surgery. In this work, a progressive development route was investigated to enhance the performance of piezoelectric composites incorporated with different shape, concentration and connectivity of ZnO fillers. ZnO microrods (MRs) have been successfully synthesized homogeneously in aqueous solution using a novel process-based on chemical bath deposition (CBD) method. The morphological analysis along with Raman scattering and cathodoluminescence spectroscopy of ZnO MRs confirm their high crystalline quality, their orientation along the polar c-axis and the presence of hydrogen-related defects acting as shallow donors in their center. The experimental characterizations highlight that ZnO MR-based composites, with a higher aspect ratio (AR), lead to a significant improvement in the mechanical, dielectric and piezoelectric properties as opposed to the ZnO microparticles (MP) counterparts. The dielectrophoretic (DEP) process is then subjected to both ZnO MP- and MR-based composites, whose performance is expected to be improved as compared to the randomly dispersed composites, thanks to the creation of chain-like structures along the electric field direction. Furthermore, a numerical simulation using COMSOL software is developed to evaluate the influence of the material structuration as well as the filler’s shape on the electric field distribution within different phases (filler, matrix and interface) of the composites. Finally, the aligned MR piezoelectric composites are revealed to be high potential in the development of innovative compact and biocompatible force-sensing devices. Such a technological breakthrough allows the achievement of a real-time precise characterization of mitral valve (MV) coaptation to assist surgeons during MV repair surgery.