Xiaoyong Sun

Dr. Xiaoyong Sun

School of Automation, Beijing Institute of Technology, Beijing, China
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2020 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Xiaoyong SunXiaoyong Sun
Xiaoyong Sun
Z. Q. ZhuZ. Q. Zhu
Z. Q. Zhu
The DC winding induced voltage in hybrid excited machines can lead to DC winding current ripple and hence fluctuating field excitation. It may also challenge the DC power source and increase the difficulty of machine control, especially at high speed. The DC winding induced voltage in a hybrid-excited switched-flux permanent magnet (HESFPM) machine is investigated in this paper. The phenomenon and mechanism of the DC winding induced voltages under both open-circuit and on-load conditions are analysed, with particularly emphasis on on-load operation which consists of open-circuit induced voltage and armature current induced voltage, respectively. Two techniques, i.e. rotor step skewing and unequal rotor teeth, are proposed and comparatively investigated by the finite element (FE) method to suppress the DC winding induced voltage under on-load condition. FE results show that the peak-to-peak value of on-load DC winding induced voltage can be effectively suppressed by 96.15% or 89.05% by rotor step skewing or unequal rotor teeth, respectively, whilst the average on-load electromagnetic torque can be maintained at 89.4% or 87.8%. A prototype HESFPM machine is built and tested to verify the FE results.

2 November 2020 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
Xiaoyong SunXiaoyong Sun
Xiaoyong Sun
Z. Q. ZhuZ. Q. Zhu
Z. Q. Zhu
SCS. Cai
S. Cai
LWLu Wang
Lu Wang
FWF. R. Wei
F. R. Wei
BSBo Shao
Bo Shao
The induced voltage ripple in DC field windings can cause many problems in hybrid excitation machines (HEMs). It can generate ripple current in field winding, thus causing unsteady magnetic field excitation and hence additional torque ripple and losses. Besides, the torque and power density of hybrid excitation machines may be deteriorated as a result of the influence of the induced voltage ripple on field winding's excitation circuit, particularly under high-speed conditions. Based on a hybrid excitation switched flux machine (HESFM), the influence of stator slot and rotor pole number combination on no-load and on-load field winding induced voltage ripples are studied and compared by the finite element method (FEM). It reveals that the harmonic content and thus the peak-to-peak value of the field winding induced voltage ripple are closely related to the stator slot and rotor pole number combination at both no-load and on-load operating conditions. The FEM calculations are verified by experiments on a prototype HESFM.

7 July 2021 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Xiaoyong SunXiaoyong Sun
Xiaoyong Sun
Z. Q. ZhuZ. Q. Zhu
Z. Q. Zhu
FWFang Rui Wei
Fang Rui Wei
Voltage pulsation induced in DC field winding of hybrid excitation machines can cause current ripple in DC field winding and may even lead to unstable field excitation. Moreover, it may also impair the torque performance and complicate the drive, especially at high speed. In this paper, the voltage pulsation induced in the DC field winding of different hybrid excitation switched flux machines (HESFMs) under both open-circuit and on-load conditions are comparatively studied. It shows that the HESFM topologies significantly affect the DC field winding induced voltage pulsations. To further suppress the induced voltage in field winding, three suppression methods, i.e., rotor step skewing, rotor pole notching, and rotor pole shaping are proposed and compared. It reveals that rotor step skewing has the best suppression performance. Finally, a prototype HESFM with both non-skewed and 2-step skewed rotors are fabricated and tested to confirm the finite element analyses (FEA).

14 February 2022 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
FWFangrui Wei
Fangrui Wei
Z. Q. ZhuZ. Q. Zhu
Z. Q. Zhu
Xiaoyong SunXiaoyong Sun
Xiaoyong Sun
LYLuocheng Yan
Luocheng Yan
JQJi Qi
Ji Qi
This article proposes and investigates two asymmetric consequent-pole hybrid excited flux reversal machine (AS-CP-HEFRM) topologies, which have same numbers of iron poles and permanent magnets (PMs) with concentrated ac and dc windings on each stator pole and a salient pole rotor. If PM number on one stator pole is larger than 1, PMs are magnetized radially in the same direction on one stator pole, while opposite on adjacent stator poles. The phenomenon of the phase shift between the flux linkages of dc and PM excitations in the AS-CP-HEFRMs is revealed for the first time, which will weaken the regulation of dc excitation field to PM produced field. The elimination condition of the phase shift is derived and verified by finite-element analysis in this article, which can be considered as design guidelines in AS-CP-HEFRMs. Airgap magnetic field space harmonics of AS-CP-HEFRM are also investigated and verified by finite-element analyses. Meanwhile, the relationship between the rotor pole number and the stator pole arc (PM ratio) is derived and verified by global optimization based on genetic algorithm for maximum average torque. The influence of stator/rotor pole number combinations is also studied and compared in terms of torque, torque ripple, and flux regulation capability. The torque components produced by airgap magnetic field space harmonics are calculated and compared. A prototype has been built and tested to validate the finite element calculations.

30 January 2024 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
LWLu Wang
Lu Wang
Z. Q. ZhuZ. Q. Zhu
Z. Q. Zhu
Xiaoyong SunXiaoyong Sun
Xiaoyong Sun
FWFangrui Wei
Fangrui Wei
Dawei LiangDawei Liang
Dawei Liang
The 150 $^\circ $ mode 12-step control (150-TSC) is suitable for high-speed drives since it can generate a quasi-sinusoidal current waveform compared with the conventional 120 $^\circ $ mode six-step control. However, for high-speed brushless direct current drives, the relatively large commutation angle of 150-TSC will cause a noticeable phase delay error. Additionally, the low switch-to-fundamental ratio will cause significant pulsewidth modulation (PWM) delay, which leads to large current oscillation and ripple. In this article, an asynchronous PWM scheme is proposed for 150-TSC to eliminate PWM delays. A phase delay error compensation method based on stator current is further proposed. The optimal phase advance angle is generated for minimum stator current magnitude with the help of the gradient descent optimization algorithm. A quasi-sinusoidal phase current can be achieved and the current harmonics can be reduced. The effectiveness of the proposed strategy is verified by experimental results.

16 January 2025 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
Chao ChenChao Chen
Chao Chen
Xiaoyong SunXiaoyong Sun
Xiaoyong Sun
ZCZhen Chen
Zhen Chen
XLXiangdong Liu
Xiangdong Liu
Z. Q. ZhuZ. Q. Zhu
Z. Q. Zhu
XLXiaozhong Liao
Xiaozhong Liao
Multiphase permanent magnet synchronous motors (PMSMs) driven by the current source inverters (CSIs) are widely used in safety-critical applications, due to their fault-tolerant capability and high torque/power density. Nevertheless, the fault-tolerant field-oriented control method based on reduced order transformation matrices for addressing the adjacent double-phase open-circuit fault (ADP-OCF) in the CSI has not yet been established. Moreover, the influence of faulty phase winding currents has not been analyzed and suppressed. Hence, this article develops a fault-tolerant control approach that includes compensation for faulty phase winding currents in the case of ADP-OCF in the CSI. First, the optimized fault-tolerant winding currents are derived. Subsequently, the decoupled mathematical model and fault-tolerant space-vector-pulsewidth-modulation (PWM) strategy are established, and finally the fault-tolerant control is achieved. The effectiveness of the proposed fault-tolerant control scheme has been validated in the experimental results. Additionally, the utilization of compensating for faulty phase winding currents can lead to a further reduction in electromagnetic torque ripple by 19.32%.