Partial discharge (PD) detection from protrusion defects is performed in an actual gas-insulated switchgears (GISs) based on a built-in sensor integrated with fluorescent fiber and ultrahigh frequency (UHF) antenna. The characteristics of both optical and UHF signals are analyzed in terms of inception voltage, pulse distribution, and statistical characteristics including the phase-resolved partial discharge (PRPD) pattern and PD number. In the experiment, protrusions with different curvatures are adopted to investigate the reason for the differences in the characteristics of UHF and optical signals. The results show that UHF and optical methods have different detection sensitivity for different discharge types owing to the different energies of electromagnetic waves and optical signals radiated in different discharge types. The optical method can easily detect avalanche discharge, while the UHF method can easily detect streamer discharge. This difference leads to the difference of the PD characteristics obtained by the two partial methods. For example, for the PD of small curvature protrusions, the PD inception voltage (PDIV) of the optical method is lower than that of the UHF method, because the defect triggers avalanche discharge. Moreover, the optical and UHF signal pulses are not always simultaneous in the time domain because they detect different discharge types. The PRPD patterns obtained by the optical method have a wider phase distribution than the UHF method because the optical method can detect avalanche discharge under low voltage.

19 February 2018 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Junhao LiJunhao Li
Junhao Li
Xuanrui ZhangXuanrui Zhang
Xuanrui Zhang
XHXutao Han
Xutao Han
XYXiu Yao
Xiu Yao
A partial discharge (PD) detection method for SF6 insulated inverted current transformers (SIICTs) adopting inner shield case as ultra-high frequency (UHF) sensor is proposed in this paper. Inner shield case is a component of the SF6 insulated inverted current transformer. Its structure is similar to that of an antenna and can be used as UHF sensor to measure the PD UHF signal. A 110kV current transformer is used as experimental object and the voltage standing-wave ratio (VSWR) of the inner shield case is calculated. The validity and sensitivity of this method are proved by experiments with AC voltage. This PD detection method solves the problem that the UHF sensor is difficult to be mounted inside current transformers and provides a novel method for PD detection of SF6 insulated inverted current transformers.

3 May 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ZZZhaoyu Zhang
Zhaoyu Zhang
Junhao LiJunhao Li
Junhao Li
YSYanfeng Song
Yanfeng Song
YSYuan Sun
Yuan Sun
Xuanrui ZhangXuanrui Zhang
Xuanrui Zhang
XHXu Tao Han
Xu Tao Han
The faults of electrical equipment are mainly generated by electrical and mechanical defects, which are usually detected by external ultrasonic and vibration sensors respectively. To improve the accuracy and efficiency of the diagnosis, a novel ultrasound-vibration composite sensor(UVCS) which can detect ultrasound and vibration acceleration signals synchronously at the same place, is proposed and developed scientifically in this paper. The working principle of UVCS is based on the combination of the mass and the backing as well as the steel base and matching layer, and the structure is improved reasonably. Furthermore, the ultrasound and vibration signals can be separated by filtering. In addition, the test results on a 110kV GIS show the high precision and reliability of UVCS and illustrate the superiority in practical application.

8 March 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Xuanrui ZhangXuanrui Zhang
Xuanrui Zhang
MSMinxia Shi
Minxia Shi
JCJun Cai
Jun Cai
Junhao LiJunhao Li
Junhao Li

10 January 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Xuanrui ZhangXuanrui Zhang
Xuanrui Zhang
MSMinxia Shi
Minxia Shi
CHCong He
Cong He
Junhao LiJunhao Li
Junhao Li
This letter proposed a new lightning impulse test method for power transformers based on oscillating lightning impulse(OLI) waveform. The OLI has high generation efficiency and is easy to generate for field test. Partial discharge detection and transfer function analysis are used to evaluate the transformer insulation condition during the impulse test. The OLI waveform for transformer test satisfied with the requirements of the standard is obtained by altering the value of resistance and inductance in the circuit. The experiment was carried out on a transformer scale model to prove the validity of the proposed method. The results show that the current pulse method and the UHF method detect the PDs simultaneously as the insulation defect is excited at high voltage. Meanwhile, the transfer function changes due to the discharge in winding. It provides a new test and insulation diagnose method with application prospects for transformer lightning impulse test on site.

21 September 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Xutao HanXutao Han
Xutao Han
Xuanrui ZhangXuanrui Zhang
Xuanrui Zhang
HWHaotian Wang
Haotian Wang
YSYuan Sun
Yuan Sun
YZYang Zhou
Yang Zhou
Junhao LiJunhao Li
Junhao Li
In this study, the partial discharge (PD) characteristics of nonuniform electric fields in SF6 and SF6/N2 gases from PD inception to intermittent breakdown under negative dc voltage were systematically studied. The effects of the gas mixture ratio and electric field distortion on the PD characteristics were analyzed in terms of PD inception voltage (PDIV), PD amplitude, PD repetition frequency, and time-resolved PD (TRPD) patterns. The PDIV of SF6/N2 was higher than that of SF6 within a certain range of gas mixture ratios, which is related to the degree of electric field distortion. The greater the degree of electrical field distortion, the greater the range of gas mixing ratios, in which the PDIV of SF6/N2 was higher than that of SF6. The difference in the value of PDIV also increased with an increase in the degree of electrical field distortion. The PD amplitude and PD repetition frequency in SF6/N2 gradually increased with increasing applied voltage. Moreover, the smaller the SF6 content, the greater the PD amplitude and repetition frequency. In SF6, the PD amplitude significantly increased and the PD repetition frequency significantly decreased when the applied voltage increased to a high value. The shape features of the TRPD patterns in both SF6 and SF6/N2 changed with an increase in the applied voltage, but the change in SF6 was more obvious than that in SF6/N2.