Guangcan Xu

Dr. Guangcan Xu

Ophthalmology, Chinese PLA General Hospital, Beijing, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
YLYu Luo
Yu Luo
GXGuangcan Xu
Guangcan Xu
HLHongyu Li
Hongyu Li
TMTianju Ma
Tianju Ma
ZYZi Ye
Zi Ye
ZLZhaohui Li
Zhaohui Li
The fluidics system is an indispensable and primary component of phacoemulsification. Both the gravity-fluidics system and active-fluidics system are commonly used in practice. The irrigation pressure of the gravity-fluidics system is determined by the bottle height, which is relatively constant, while the active-fluidics system is paired with a cassette that contains pressure sensors to monitor intraocular pressure changes. The active-fluidics system allows surgeons to preset a target intraocular pressure value, and it replenishes the fluids proactively; thus, the intraocular pressure is consistently maintained near the target value. Under such circumstances, stable intraocular pressure and anterior chamber volume values could be acquired. Research on surgical safety, efficiency and results have reported several strengths of the active-fluidics system. It is also advantageous in some complicated cataract surgeries. However, the system is not widely used at present, mainly due to its low penetration rate and high equipment cost. Some of its updates such as the new Active Sentry handpiece showed potential superiority in laboratory studies recently, but there is still further research to be conducted. This article gives an overview of the mechanism and performance of the active-fluidics system, and it is expected to provide clues for future research.

6 February 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
YLYu Luo
Yu Luo
GXGuangcan Xu
Guangcan Xu
HLHongyu Li
Hongyu Li
TMTianju Ma
Tianju Ma
ZYZi Ye
Zi Ye
ZLZhaohui Li
Zhaohui Li
Background: Corneal edema (CE) affects the outcome of phacoemulsification. Effective ways to predict the CE after phacoemulsification are needed. Methods: On the basis of data from patients conforming to the protocol of the AGSPC trial, 17 variables were selected to predict CE after phacoemulsification by constructing a CE nomogram through multivariate logistic regression, which was improved via variable selection with copula entropy. The prediction models were evaluated using predictive accuracy, the area under the receiver operating characteristic curve (AUC), and decision curve analysis (DCA). Results: Data from 178 patients were used to construct prediction models. After copula entropy variable selection, which shifted the variables used for prediction in the CE nomogram from diabetes, best corrected visual acuity (BCVA), lens thickness and cumulative dissipated energy (CDE) to CDE and BCVA in the Copula nomogram, there was no significant change in predictive accuracy (0.9039 vs. 0.9098). There was also no significant difference in AUCs between the CE nomogram and the Copula nomogram (0.9637, 95% CI 0.9329–0.9946 vs. 0.9512, 95% CI 0.9075–0.9949; p = 0.2221). DCA suggested that the Copula nomogram has clinical application. Conclusions: This study obtained a nomogram with good performance to predict CE after phacoemulsification, and showed the improvement of copula entropy for nomogram models.

17 August 2024 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
GXGuangcan Xu
Guangcan Xu
HQHaolan Qi
Haolan Qi
QHQianwei He
Qianwei He
MCMingxiong Chen
Mingxiong Chen
JFJunxia Fu
Junxia Fu
LWLiqiang Wang
Liqiang Wang
Purpose This study evaluates the predictive power of the critical flicker fusion frequency (CFF) test for visual outcomes in keratoprosthesis (KPro) candidates, comparing its accuracy with B-scan ultrasound, flash visual evoked potentials (fVEP) and endoscopy. Methods The study included 42 patients (42 eyes) scheduled for KPro surgery with a median follow-up period of 6 months. The receiver operating characteristic curve identified the cut-off threshold for CFF in the model development study (17 eyes). All patients in the comparison study (25 eyes) underwent preoperative assessments including trichromatic CFF (red, green and yellow), B-scan ultrasound, fVEP and perioperative endoscopy. Results were classified as either favourable or unfavourable predictors of visual outcomes based on predefined criteria. Sensitivity and specificity of each assessment were calculated based on postoperative best-corrected visual acuity (BCVA)≥20/200. The Bland-Altman test assessed the consistency between CFF-predicted BCVA and actual BCVA. Results Among the trichromatic CFF tests, the yellow-CFF (yCFF) exhibited the highest area under the curve value of 0.97 and a cut-off threshold at 10 Hz for predicting postoperative BCVA≥20/200 (p<0.05). yCFF achieved 90% sensitivity and 80% specificity in predicting satisfactory postoperative outcomes. Endoscopy had 80% sensitivity and 80% specificity, B-scan showed 70% sensitivity and 60% specificity, and fVEP had 75% sensitivity and 40% specificity. yCFF showed a mean bias of 0.091 logarithm of the minimum angle of resolution (logMAR) in postoperative prediction. Conclusions The CFF test provides robust visual function evaluation in KPro candidates. It demonstrates superior predictive accuracy for visual prognosis compared with routine ophthalmologic examinations, such as B-scan ultrasonography, fVEP and endoscopy.