Yali Xue

Dr. Yali Xue

Tsinghua University, Beijing, China
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2018 in Journal of Modern Power Systems and Clean Energy
Verified
Journal Article
Open access
PDF file
XHXianzheng Huang
Xianzheng Huang
ZXZhaofeng Xu
Zhaofeng Xu
YSYong Sun
Yong Sun
YXYali Xue
Yali Xue
Zhe WangZhe Wang
Zhe Wang
WNWeidou NI
Weidou NI
As one of promising clean and low-emission energy, wind power is being rapidly developed in China. However, it faces serious problem of wind curtailment, particularly in northeast China, where combined heat and power (CHP) units cover a large proportion of the district heat supply. Due to the inherent strong coupling between the power and the heat load, the operational flexibility of CHP units is severely restricted in winter to meet the heat supply demand, which imparts considerable stress on the wind power connection to the grid. To promote the integration of wind power and enhance the flexibility of CHP units, this paper presented a method of heat and power load dispatching by exploring the energy storage ability of electric heating boilers and district heating systems. The optimization results indicate that the proposed method can integrate additional wind power into the grid and reduce the coal consumption of CHP units over the optimized period. Furthermore, the thermal inertia of a district heating system is found to contribute more to the reduction of coal consumption, whereas the electric heating boilers contribute to lower wind curtailment.

28 August 2017 in Sustainability
Verified
Journal Article
Open access
PDF file
LSLi Sun
Li Sun
QHQingsong Hua
Qingsong Hua
Jiong ShenJiong Shen
Jiong Shen
YXYali Xue
Yali Xue
Donghai LiDonghai Li
Donghai Li
Kwang Y. LeeKwang Y. Lee
Kwang Y. Lee
Control of output voltage is critical for the power quality of solid oxide fuel cells (SOFCs), which is, however, challenging due to electrochemical nonlinearity, load disturbances, modelling uncertainties, and actuator constraints. Moreover, the fuel utilization rate should be limited within a safety range during the voltage regulation transient. The current research is usually appealing to model predictive control (MPC) by formulating the difficulties into a constrained optimization problem, but its huge computational complexity makes it formidable for real-time implementation in practice. To this end, this paper aims to develop a combined control structure, with basic function blocks, to fulfill the objectives with minor computation. Firstly, the disturbance, nonlinearity and uncertainties are lumped as a total disturbance, which is estimated and mitigated by active disturbance rejection controller (ADRC). Secondly, a feed-forward controller is introduced to improve the load disturbance rejection response. Finally, the constraints are satisfied by designing a cautious switching strategy. The simulation results show that the nominal performance of the proposed strategy is comparable to MPC. In the presence of parameter perturbation, the proposed strategy shows a better performance than MPC.

8 October 2019 in Processes
Verified
Journal Article
Open access
PDF file
ZWZhenlong Wu
Zhenlong Wu
Donghai LiDonghai Li
Donghai Li
YXYali Xue
Yali Xue
The maximum sensitivity function as the conventional robustness index is often used to test the robustness and cannot be used to tune the controller parameters directly. To reduce analytical difficulties in dealing with the maximum sensitivity function and improve the control performance of the proportional-integral-derivative controller, the relative delay margin as a good alternative is proposed to offer a simple robust analysis for the proportional-integral-derivative controller and the first-order plus dead-time systems. The relationship between the parameters of the proportional-integral-derivative controller and the new pair, e.g., the phase margin and the corresponding gain crossover frequency, is derived. Based on this work, the stability regions of the proportional-integral-derivative controller parameters, the proportional gain and the integral gain with a given derivative gain, are obtained in a simple way. The tuning of the proportional-integral-derivative controller with constraints on the relative delay margin is simplified into an optimal disturbance rejection problem and the tuning procedure is summarized. For convenience, the recommended parameters are also offered. Simulation results demonstrate that the proposed methodology has better tracking and disturbance rejection performance than other comparative design methodologies of the proportional-integral/proportional-integral-derivative controller. For example, the integrated absolute errors of the proposed proportional-integral-derivative controller for the tracking performance and disturbance rejection performance are less than 91.3% and 91.7% of the integrated absolute errors of other comparative controllers in Example 3, respectively. The proposed methodology shows great potential in industrial applications. Besides, the proposed method can be applied to the design of the proportional-integral-derivative controller with filtered derivative which is recommended for practical applications to weaken the adverse influence of the high-frequency measurement noise.

22 March 2019 in Energies
Verified
Journal Article
Open access
PDF file
Fan ZhangFan Zhang
Fan Zhang
YXYali Xue
Yali Xue
Donghai LiDonghai Li
Donghai Li
ZWZhenlong Wu
Zhenlong Wu
THTing He
Ting He
Supercritical circulating fluidized bed (CFB) is one of the prominent clean coal technologies owing to the advantages of high efficiency, fuel flexibility, and low cost of emission control. The fast and flexible load-tracking performance of the supercritical CFB boiler-turbine unit presents a promising prospect in facilitating the sustainability of the power systems. However, features such as large inertia, strong nonlinearity, and multivariable coupling make it a challenging task to harmonize the boiler’s slow dynamics with the turbine’s fast dynamics. To improve the operational flexibility of the supercritical CFB unit, a burning carbon based decentralized active disturbance rejection control is proposed. Since burning carbon in the furnace responds faster than throttle steam pressure when the fuel flow rate changes, it is utilized to compensate the dynamics of the corresponding loop. The parameters of the controllers are tuned by optimizing the weighted integrated absolute error index of each loop via genetic algorithm. Simulations of the proposed method on a 600 MW supercritical CFB unit verify the merits of load following and disturbance rejection in terms of less settling time and overshoot.

1 October 2020 in ISA Transactions
Verified
Journal Article
Closed access
ZWZhenlong Wu
Zhenlong Wu
JYJie Yuan
Jie Yuan
Donghai LiDonghai Li
Donghai Li
YXYali Xue
Yali Xue
YangQuan ChenYangQuan Chen
YangQuan Chen

8 April 2018 in Sustainability
Verified
Journal Article
Open access
PDF file
ZWZhenlong Wu
Zhenlong Wu
THTing He
Ting He
LSLi Sun
Li Sun
DLDonghai Li
Donghai Li
YXYali Xue
Yali Xue
An increasing penetration of renewable energy may bring significant challenges to a power system due to its inherent intermittency. To achieve a sustainable future for renewable energy, a conventional power plant is required to be able to change its power output rapidly for a grid balance purpose. However, the rapid power change may result in the boiler operating in a dangerous manner. To this end, this paper aims to improve boiler control performance via a data-driven control strategy, namely Active Disturbance Rejection Control (ADRC). For practical implementation, a tuning method is developed for ADRC controller parameters to maximize its potential in controlling a boiler operating in different conditions. Based on a Monte Carlo simulation, a Probabilistic Robustness (PR) index is subsequently formulated to represent the controller’s sensitivity to the varying conditions. The stability region of the ADRC controller is depicted to provide the search space in which the optimal group of parameters is searched for based on the PR index. Illustrative simulations are performed to verify the efficacy of the proposed method. Finally, the proposed method is experimentally applied to a boiler’s secondary air control system successfully. The results of the field application show that the proposed ADRC based on PR can ensure the expected control performance even though it works in a wider range of operating conditions. The field application depicts a promising future for the ADRC controller as an alternative solution in the power industry to integrate more renewable energy into the power grid.