Yanzhe Yu

Dr. Yanzhe Yu

Tianjin Univercity
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019 in Energy Policy
Verified
Journal Article
Closed access
Yanzhe YuYanzhe Yu
Yanzhe Yu
JCJie Cheng
Jie Cheng
SYShijun You
Shijun You
TYTianzhen Ye
Tianzhen Ye
HZHuan Zhang
Huan Zhang
SLShan Liu
Shan Liu

26 September 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YWYuanyuan Wang
Yuanyuan Wang
Yanzhe YuYanzhe Yu
Yanzhe Yu
TYTianzheng Ye
Tianzheng Ye
QBQuan Bo
Quan Bo
As most existing office buildings in China lack fresh air systems for ventilation, natural ventilation with windows remains the main means of improving indoor air quality and adjusting indoor thermal comfort. However, knowledge of the ventilation characteristics of various window-opening forms in actual buildings is limited and current methods for evaluating ventilation performance lack a comprehensive consideration of ventilation rate and thermal comfort. In this study, the ventilation characteristics of different window-opening forms were systematically compared by conducting computational fluid dynamics (CFD) simulations. A full-scale experiment was conducted in a typical office room in a university in Tianjin to validate the CFD simulation. Two ventilation modes (wind-driven cross-ventilation and temperature-driven single-sided ventilation), three window-opening angles, and seven window types were investigated. Additionally, the ratio of the ventilation rate to the absolute value of thermal sensation was used to quantify the indoor natural-ventilation performance. The results showed that a sliding window with a full opening has the highest discharge coefficients of 0.68 and 0.52 under wind-driven cross-ventilation and temperature-driven single-sided ventilation, respectively, and top-hung windows opening both inwards and outwards have better ventilation performance than other window types under the two ventilation modes. This study is applicable to the design and practice of natural ventilation.

19 June 2024 in Journal of Cleaner Production
Verified
Journal Article
Closed access
XGXingguo Guo
Xingguo Guo
XCXingxin Chen
Xingxin Chen
Yanzhe YuYanzhe Yu
Yanzhe Yu
SWShen Wei
Shen Wei
WCWenhua Chen
Wenhua Chen

28 May 2022 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
XZXuejing Zheng
Xuejing Zheng
XYXueqing Yang
Xueqing Yang
HMHongfei Miao
Hongfei Miao
HLHuzhen Liu
Huzhen Liu
Yanzhe YuYanzhe Yu
Yanzhe Yu
SYShijun You
Shijun You

1 September 2021 in Air Quality, Atmosphere & Health
Verified
Journal Article
Closed access
PDF file
Yanzhe YuYanzhe Yu
Yanzhe Yu
WBWang Bei
Wang Bei
SYShijun You
Shijun You
TYTianzheng Ye
Tianzheng Ye
Wandong ZhengWandong Zheng
Wandong Zheng
KLKun Li
Kun Li

18 August 2021 in Building Services Engineering Research & Technology
Verified
Journal Article
Closed access
PDF file
Yanzhe YuYanzhe Yu
Yanzhe Yu
SYShijun You
Shijun You
HZHuan Zhang
Huan Zhang
TYTianzhen Ye
Tianzhen Ye
Yaran WangYaran Wang
Yaran Wang
SWShen Wei
Shen Wei
Due to the humid underground environment, underground metro stations often have internal condensation issues, especially during the commissioning and initial operation phases, and these issues will have a negative impact on the equipment operation and building life. This study aims to solve the issue by 1) identifying common areas with condensation risks based on on-site measurements and numerical simulation methods, and 2) proposing effective dehumidification solutions for the moisture control of stations. By on-site investigating the characteristics of the station’s moisture environment and numerical assessing the effects of two different dehumidification strategies, it has been found that 1) for Tianjin, during most times in summer, the air temperature of the station in the commissioning phase was maintained relatively stable, but with significantly changing humidity; 2) the relative humidity on the platforms was higher than 80% for almost 30% of the testing time, and the surface of the upper structure of platform doors having a high risk of condensation; 3) the dehumidification effect of industrial dehumidifiers was found to be better than that of increasing exhaust air volume. The authors hope that the research could aid the decision on dehumidification strategies and provide guidance for further moisture control in underground stations. Practical Application: This article analyzed the moisture environment of the underground metro stations in the commissioning phase and conducted a numerical approach to assess the condensation risk. Potential dehumidification solutions including increasing the exhaust air volume and using industrial dehumidifiers have been proposed, and their effects have been investigated and compared. The authors hope that this research can aid the decision on dehumidification strategies for facilities maintenance and provide a guidance to further moisture control in underground stations.