Yasaman Anbari

Ms. Yasaman Anbari

The University of Texas MD Anderson Cancer Center, Houston, Texas, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2023 in Journal of Interventional Medicine
Verified
Journal Article
Open access
YAYasaman Anbari
Yasaman Anbari
FVFloortje E. Veerman
Floortje E. Veerman
GKGrace Keane
Grace Keane
ABArthur Johannes Anthonius Theodorus Braat
Arthur Johannes Anthonius Theodorus Braat
MSMaarten L.J. Smits
Maarten L.J. Smits
MLMarnix G.E.H. Lam Lam
Marnix G.E.H. Lam Lam
Liver malignancy, including primary liver cancer and metastatic liver cancer, has become one of the most common causes of cancer-related death worldwide due to the high malignant degree and limited systematic treatment strategy. Radioembolization with yttrium-90 (90Y)-loaded microspheres is a relatively novel technology that has made significant progress in the local treatment of liver malignancy. The different steps in the extensive work-up of radioembolization for patients with an indication for treatment with 90Y microspheres, from patient selection to follow up, both technically and clinically, are discussed in this paper. It describes the application and development of 90Y microspheres in the treatment of liver cancer.

1 September 2026 in Life
Verified
Journal Article
Open access
PDF file
YAYasaman Anbari
Yasaman Anbari
BLBenjamin Lopez
Benjamin Lopez
AMArmeen Mahvash
Armeen Mahvash
AYAli Yousefi
Ali Yousefi
SKS. Cheenu Kappadath
S. Cheenu Kappadath
Patient demographic-based standard liver volume (SLV) models are widely used to estimate patient-specific hepatic metabolic demand and support future liver remnant assessment after hepatectomy. These formulae rely on anthropometric variables such as weight, height, and body surface area; however, their accuracy for individual patients remains uncertain. In an exploratory single-center study, we evaluated ten published SLV formulae and one in-house multivariable regression model against CT-derived liver volumes as the anatomic reference standard in 100 patients with normal livers, using Bland–Altman analysis. Mean percentage bias ranged from −20% to +11%, with only 4–32% of cases achieving prediction errors within ±5%, and the 95% limits of agreement were wide for every model, spanning from ±25% to ±36% around the mean bias. Because percentage bias is expressed relative to the measured volume, the width of the limits of agreement was almost entirely determined by calibration (r = 0.99 with signed mean bias). Once this scaling was removed, the ten published formulae were indistinguishable, with calibration-adjusted limits of agreement of ±31.3% to ±32.7% (mean ±32.0%, SD 0.40). Rescaling each formula by a single multiplicative constant (0.924 to 1.282) reduced mean bias to between +1.2% and +3.6% and converged the limits of agreement to ±32.4% to ±33.1%, raising the proportion of patients estimated within ±10% from 13% to 54% for the most poorly calibrated formula; refitting both slope and intercept gave no further improvement. The in-house model, using five predictors fitted within this cohort, reached ±29.4% and was the only specification below this floor. In this exploratory single-center cohort, prediction error was wide across the observed range and showed no dependence on predicted liver volume. The limitations for SLV appear to lie in the demographic predictors rather than in the reference measurements. Therefore, future work should focus on predictors that capture information beyond body size, such as measures of body composition or liver function.