Yunho Kim

Mr. Yunho Kim

Kyungpook National University, Daegu, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
Yunho KimYunho Kim
Yunho Kim
YPYunHa PARK
YunHa PARK
HSHyuncheol Seo
Hyuncheol Seo
JHJungha HWANG
Jungha HWANG
Recently, building automation system (BAS) and building energy management system (BEMS) technologies have been applied to efficiently reduce the energy consumption of buildings. In addition, studies on utilizing large quantities of building data have been actively conducted using artificial intelligence and machine learning. However, the high cost and installation difficulties limit the use of measuring devices to sense the indoor environment of all buildings. Therefore, this study developed a comprehensive indoor environment sensor module with relatively inexpensive sensors to measure the indoor environment of a university building. In addition, an algorithm for predicting the load in real time through machine learning based on indoor environment measurement is proposed. When the reliability of the algorithm for predicting the number of occupants and load according to the indoor CO2 concentration was quantitatively assessed, the mean squared error (MSE), root mean square deviation (RMSD), and mean absolute error (MAE) were calculated to be 23.1, 4.8, and 2.5, respectively, indicating the high accuracy of the algorithm. Since the sensor used in this study is economical and can be easily applied to existing buildings, it is expected to be favorable for the dissemination of load prediction technology.

1 January 2017 in Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
Verified
Journal Article
Closed access
PDF file
TKTae-Yeon Kim
Tae-Yeon Kim
Yunho KimYunho Kim
Yunho Kim
JHJung-Ha Hwang
Jung-Ha Hwang

22 March 2022 in Energies
Verified
Journal Article
Open access
PDF file
Yunho KimYunho Kim
Yunho Kim
JHJungha HWANG
Jungha HWANG
SBSangmu Bae
Sangmu Bae
YNYujin Nam
Yujin Nam
Recently, there has been increasing attention on the use of renewable energy in buildings, particularly, the photovoltaic thermal (PVT) system that uses both solar power and thermal energy. However, there is a limit to adopting the PVT system in real buildings because many architects value the aesthetics of buildings or spaces. This study developed a curtain-wall-type liquid-type PVT (CW-PVT) that can be installed on a wall as it integrates with the building. To analyze the system performance, a real-scale experimental plant was established in an outdoor environment. The performance of the CW-PVT unit was verified for two different module pipe connection types: parallel and serial. Meteorological variable data, the inlet and outlet fluid temperatures, surface temperature, and electrical energy generation of the modules were measured and collected using the measurement equipment according to the module pipe connection type. Consequently, the parallel-type method was approximately 10% more efficient than the serial type in energy production, whereas the serial-type method produced water with a temperature approximately 47% higher than that of the parallel type. Notably, it was advantageous to apply the parallel-type connection to maximize the energy generation efficiency in buildings where the system efficiency is vital and the serial-type connection in buildings where the high temperature of hot water is required.

1 December 2016 in Journal of the Korean Solar Energy Society
Verified
Journal Article
Closed access
PDF file
Yunho KimYunho Kim
Yunho Kim
YPYun-Ha Park
Yun-Ha Park
AWAn-Na Won
An-Na Won
JHJung-Ha Hwang
Jung-Ha Hwang

29 September 2026 in Buildings
Verified
Journal Article
Open access
PDF file
YPYunHa PARK
YunHa PARK
Yunho KimYunho Kim
Yunho Kim
JHJungha HWANG
Jungha HWANG
Visiting patients and medical staff share the same air in outpatient departments of general hospitals. In South Korea, 11 of 15 general hospitals operate with a fixed ratio of 20% outdoor air and 80% recirculated air even during peak visiting hours, causing the recirculation of indoor airborne pathogens. In this study, we propose a scheduling strategy in which air conditioning is adjusted proactively according to the number of visiting patients. The number of visiting patients was measured over five weeks with a people counter. The count showed a regular pattern: an increase in the morning, a decrease at lunch, and a sharp rise in the afternoon. Based on this pattern, we designed a pre-delay schedule for the air conditioning system in which the air intake rate is increased before the increase in visiting patients and maintained for some time after the decrease. The efficacy of this strategy was verified through mock-up room evaluations and full-plane CFD simulations. In the mock-up room tests, the pre-delay operation effectively suppressed particle accumulation in all three conditions. In the CFD simulations, the pathogen count in the waiting room during peak visiting patient hours decreased from the existing 12 particles/106 to 8.4 (−30.0%) with the scheduled operation and 6.8 (−43.3%) with the proposed pre-delay operation. Thus, the proposed method can be applied in existing facilities without modifying an installed central air conditioning system because primarily the air intake rate is adjusted within the airflow range that the existing central air conditioning system can deliver, without adding or modifying equipment.

30 December 2015 in Journal of the Korean Solar Energy Society
Verified
Journal Article
Closed access
YPYun-Ha Park
Yun-Ha Park
Yunho KimYunho Kim
Yunho Kim
AWAn-Na Won
An-Na Won
JHJung-Ha Hwang
Jung-Ha Hwang