Yongquan Su

Mr. Yongquan Su

Shanghai University, Shanghai, China
+1

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 September 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
YLYichen Liu
Yichen Liu
LWLihao Wang
Lihao Wang
YSYongquan Su
Yongquan Su
YZYuyao Zhang
Yuyao Zhang
YWYang Wang
Yang Wang
ZWZhenyu Wu
Zhenyu Wu
This paper presents AlScN piezoelectric two-axis MEMS mirrors with gimbal-less and gimbaled designs fabricated in a CMOS-compatible manner. Integrated piezoelectric sensors provided feedback signals of the actual mirror positions. The mirror with a diameter of 1.5 mm possessed adjustable optical tilt angles of up to 22.6° @ 30 V, with a high resonance frequency of about 8.2 kHz, while the 3 mm mirror reached 48.5° @ 41 V. The mirror with the gimbaled structure exhibited an excellent field of view and good mechanical decoupling. Additionally, a significant improvement in mirror scanning performance was observed in a vacuum (4 Pa), proving that the optical field of view was magnified by more than a factor of 10.

30 December 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
LFLiuhaodong Feng
Liuhaodong Feng
SZShuwen Zeng
Shuwen Zeng
YSYongquan Su
Yongquan Su
LWLihao Wang
Lihao Wang
YXYang Xu
Yang Xu
SWShinan Wang
Shinan Wang
In order to obtain high-quality through-silicon via (TSV) arrays for high voltage applications, we optimized the fabrication processes of the Si holes, evaluated the dielectric layers, carried out hole filling by Cu plating, and detected the final structure and electric properties of the TSVs. The Si through-hole array was fabricated in an 8-inch Si substrate as follows: First, a blind Si hole array was formed by the Si deep reactive etching (DRIE) technique using the Bosch process, but with the largest width of the top scallops reduced to 540 nm and the largest notch elimidiameternated by backside grinding, which also opens the bottom ends of the Si blind holes and forms 500-μm-deep Si through holes. Then, the sidewalls of the Si holes were further smoothed by a combination of thermal oxidation and wet etching of the thermal oxide. The insulating capability of the dielectric layers was evaluated prior to metal filling by using a test kit. The metal filling of the through holes was carried out by bottom-up Cu electroplating and followed by annealing at 300 °C for 1 h to release the electroplating stress and to prevent possible large metal thermal expansion in subsequent high-temperature processes. The TSV arrays with different hole diameters and spacing were detected: no visible defects or structure peeling was found by scanning electron microscopy (SEM) observations, and no detectable interdiffusion between Cu and the dielectric layers was detected by energy dispersive X-ray (EDX) analyses. Electric tests indicated that the leakage currents between two adjacent TSVs were as low as 6.80 × 10−10 A when a DC voltage was ramped up from 0 to 350 V, and 2.86 × 10−9 A after a DC voltage was kept at 100 V for 200 s.

2 February 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
YYYang Yi
Yang Yi
YLYichen Liu
Yichen Liu
YSYongquan Su
Yongquan Su
YWYang Wang
Yang Wang
YZYonggui Zhang
Yonggui Zhang
ZWZhenyu Wu
Zhenyu Wu
This paper presents a two-axis AlScN-based water-immersible MEMS mirror fabricated in an 8-inch MEMS process. Compared with other studies, this device has a larger optical aperture 10 mm in diameter. The resonant frequencies of the device are 1011 Hz in air and 342 Hz in water. The scanning angle reaches ±5° and ±2° at resonant frequencies in air and water, respectively. The cavitation phenomenon is observed when the device is operating in water, which leads the device to electrical failure. To address this issue, a device with reduced resonant frequencies—246 Hz and 152 Hz in air and water—is characterized, through which the bubbles can be effectively prohibited. This MEMS mirror could potentially be used in ultrasound and photoacoustic microscopy applications.

2 August 2024 in Research Square
Verified
Preprint
Open access
PDF file
YZYonggui Zhang
Yonggui Zhang
HHHao Huang
Hao Huang
LWLihao Wang
Lihao Wang
YSYongquan Su
Yongquan Su
YWYang Wang
Yang Wang
ZWZhenyu Wu
Zhenyu Wu
MEMS micromirrors typically require the use of elongated torsion beams to achieve optical scanning angles in excess of 90°, but elongated torsion beam structures usually lead to problems such as larger chip areas and lower reliability. This paper designs a biaxial Lissajous scanning piezoelectric AlScN-driven MEMS micromirror driven by circular arc actuators, featuring large mirror with a diameter of 5 mm. To achieve large-angle scanning, optimizations are made in the following four aspects: 1) stress dispersion structures are adopted in the structural design; 2) an improved non-Bosch process is utilized in the manufacturing process to achieve smooth sidewall morphology; 3) vacuum packaging is employed in the packaging aspect to reduce the impact of air damping; 4) a driving method of gradually reaching the resonance peak through upward frequency sweeping is used in the control aspect, fully exploit the spring hardening effect to achieve large-angle scanning. After optimization, the mirror achieves optical scanning angles of 102.8° and 104.8° on its two axes. Furthermore, the micromirror has passed 900g shock tests and 20g vibration tests, demonstrating its good shock and vibration resistance while achieving large scanning angles.