Thermal conductivity and heat capacity are among the most essential properties of a building insulation in calculating thermal performance which are subjected to change when exposed to temperatures variation in service. Ignoring the temperature dependency of these material properties can result in under and over estimations of buildings energy uses and the corresponding equipment sizing. To obtain more realistic conductivity values of insulation materials, in this paper, thermal conductivity tests are conducted at various mean temperatures. For the study six commonly used insulations including Cellulose fiber, Expanded Polystyrene, Extruded Polystyrene, Open Cell Spray Polyurethane, Polyisocyanurate, and Mineral Wool are considered, and their thermal conductivity are measured at seven mean temperatures ranging from 5°C to 60°C. Furthermore, their specific heat capacity are measured at nine mean temperatures ranging between 16°C and 36°C. The results showed that except Polyisocyanurate board, the thermal conductivities and specific heat capacities of all insulation materials increased linearly with rising temperature, presenting a linear regression model with correlation coefficients (R2) values between 0.96 and 0.98. The curve fitting of the Polyisocyanurate thermal conductivity measurements resulted a nonlinear regression model with R2 of 0.97. The thermal conductivity of six insulations as a function of temperature have been established.
8 April 2024 in Science and Technology for the Built Environment
The reliability of hygrothermal models depends on the quality of their inputs. Conventionally, thermal and moisture properties are treated as temperature-independent, yet previous studies have shown that many of these properties are temperature-dependent. This paper investigates the impact of using temperature-dependent material properties on hygrothermal simulation results compared to standard temperature-independent properties at the building envelope level. A representative exterior wood-frame wall assembly is modelled with constant material properties, including water vapour permeability, sorption isotherm, and water absorption coefficient corresponding to values measured at 3 °C, 21 °C, and 45 °C, as well as a case in which the properties vary with temperature. The variation in hygrothermal response is evaluated under several scenarios, including different climates (Toronto and Vancouver, Canada), cladding types (fibre cement and stucco), sheathing materials (oriented strand board (OSB) and plywood), and with and without rain-penetration load. Results indicate that the variation attributed to temperature-dependent material properties was greater for Vancouver than for Toronto and increased with rain penetration. In particular, the choice of cladding seemed to have a greater impact than the choice of sheathing material, with stucco showing greater differences than fibre cement. Overall, however, the temperature at which material properties are defined has a minimal impact on hygrothermal simulation results and wall performance assessments, with maximum hourly differences in sheathing moisture content (MC) differences ranging from 1.18 to 4.32 wt% without rain penetration. These findings demonstrate that the use of temperature-dependent material properties does not have a significant impact on the hygrothermal simulation results or the performance assessment of exterior wood-frame wall assemblies.
Interactive architecture is a concept that focuses on self-governing behaviour through engagements with the environment and users. This paper introduces designing and fabricating a responsive building skin made of several small unit cells, replacing centralized and hierarchical architectural systems with open and extensible distributed networks. The proposed concept involves modular structures with adaptable building components, allowing greater flexibility, self-government, and resilience than centralized systems. A cone-shaped hexagonal electro-mechanical unit functions as a three-dimensional aperture, opening and closing mechanically using custom-made linear actuators. The aggregation of units forms a dynamic surface that can be installed inside, outside, or on both sides of a transparent wall. The interactivity of the aggregated system was simulated and calibrated using the grasshopper parametric virtual modelling plugin for Rhinoceros. A prototype of five modules was constructed and tested for thirty days, revealing the highest susceptibility to damage in the components.