Herein, a magnetic graphene field-effect transistor biosensor was prepared through the transfer of a chemical vapor deposition graphene film onto a glass substrate to produce a sensing film and conductive channel. By fixing 1-pyrenebutanoic acid succinimidyl ester onto graphene film as an anchor, a probe aptamer was immobilized on the graphene film in order to capture magnetically labeled complementary single-stranded DNA. Our experiments showed that, within a periodic magnetic field, the biosensor impedance exhibited a periodic oscillation, the amplitude of which was correlated to the complementary DNA concentration. Based on this principle, the magnetic graphene field-effect transistor was utilized to detect single-stranded DNA with detection limition of 1 pM. The results were rationalized using a model wherein the magnetic force causes the DNA strand to bend, thereby resulting in magnetic nanobeads/DNA modulation of the double conductive layer of graphene transistors. Furthermore, since a periodic magnetic field could be introduced to produce a periodic impedance changes of MGFETs, sampling integration could be used to improve the signal-to-noise ratio efficiently by increasing the number of periods of the external magnetic field. Therefore, a novel biosensor for DNA detection with high sensitivity has been presented in this work. Based on the detection principle, this system may also be a potential tool for detecting other bio-molecules, cells, etc.
In this paper, the study of an electricity-fluorescence double-checking biosensor and detection system has been presented. The fabrication of the double-checking biosensor was performed by integrating graphene field effect transistors (GFETs) and biosensors based on fluorescence resonance energy transfer (FRET). For the construction of the GFETs as an electrical detection channel, graphene films grown by chemical vapour deposition (CVD) were transferred onto glass substrates. A probe aptamer modified with 6′-carboxy-fluorescein (6′-FAM) was immobilized on the graphene film of the GFETs via 1-pyrenebutanoic acid succinimidyl ester (PBASE) following which graphene oxide (GO) was used to quench the 6′-FAM on the probe aptamer to form the fluorescence detection channel. When the complementary target DNA (tDNA) was introduced into the GFETs, it replaced the GO and was hybridized with the probe aptamer leading to restoration of the fluorescence of the probe aptamer. At the same time, the tDNA hybridized with the probe aptamer leading to the formation of a new double conductive layer of the GFETs, which could change the conductivity of the GFETs. With a home-made double channel detection system, the dynamic hybridization process of the tDNA with the probe aptamer was achieved simultaneously through the electrical and fluorescence channels. Compared with conventional biosensors that are equipped with a single detection mode, this double-checking biosensor could be used to monitor the time and concentration-dependent DNA hybridization kinetics in a reliable and sensitive manner. Furthermore, this work also provides a new strategy for designing biosensors integrated with multiple sensing techniques.
27 January 2014 in Sensors and Actuators B: Chemical
Sensitive detection of cancer biomarkers is valuable for clinical diagnosis and treatment assessment of cancers. Herein, we report a simple smartphone-based double-channel fluorescence setup for immunoassay. Not including the smartphone, the total cost of the detection device itself is about 80 $, including a laser pointer, a twinning measurement cell, a collective lens, and an outside box. The fluorescence images of the sample and reference areas were captured by the camera in the smartphone and the brightness ratio was calculated using a user-edited smartphone app. By using 2,3-diaminophenazine (DAP) as the model luminophore, the influence of exposure time and photosensitivity on the sensitivity was tested. The brightness ratio offers high stability of the fluorescence signal, which is helpful to improve the sensitivity. The applicability of this device was demonstrated by a catalytic fluorimetric method for Cu2+ determination, which is based on the oxidation of o-phenylenediamine (non-fluorescent) to DAP (strong fluorescent) by dissolved oxygen using Cu2+ as the catalyst. Accordingly, by using a CuS nanoparticle-conjugated second antibody as the signal tag, the immunoassay for a carcinoembryonic antigen was performed with the detection limit of 0.05 pg mL−1. This smartphone-based double-channel fluorescence device offers the advantages of high sensitivity, inexpensive and miniaturization.
Herein, a graphene field effect transistor (GFET) was constructed on an optical fiber end face to develop an integrated optical/electrical double read-out biosensor, which was used to detect target single-stranded DNA (tDNA).