Background: The incidences of atrial fibrillation (AF) and chronic kidney disease (CKD) are increasing, and AF is prevalent in patients with CKD. However, few studies have investigated the incidence or association of AF in a large CKD population from a longitudinal study. Methods and Results: From a nationwide cohort, a total of 4 827 987 Korean individuals without prior AF, who received biennial health checkups provided by the National Health Insurance Service between 2009 and 2012 in Korea, were analyzed. Incidence of AF was ascertained through the end of 2018. During a median follow‐up of 8.1 years, the annual incidence rate of AF was 1.17 per 1000 person‐years among subjects without CKD, 1.55 for stage 1 CKD, 1.86 for stage 2 CKD, 2.1 for stage 3 CKD, and 4.33 for stage 4 CKD. In Fine‐Gray regression models, CKD was associated with an increased risk of AF; the adjusted hazard ratios and 95% CIs of AF occurrence were 1.77 (1.69–1.85), 1.85 (1.80–1.91), 1.99 (1.95–2.04), and 4.04 (3.07–5.33) in individuals with CKD stages 1, 2, 3, and 4, respectively, compared with non‐CKD. The association between CKD and incident AF remained statistically significant after adjustment for multiple confounding factors and was consistent across subgroups stratified by sex and age. Conclusions: CKD is associated with an increased incidence of AF. Even mild CKD is associated with incident AF, and there was a stepwise increase in the risk of incident AF with a decrease in renal function.
Background and Objectives: To evaluate the stability of a dental implant and the effectiveness of a newly designed damping capacity assessment device by improving the number of blows and strength evaluated by a prospective clinical study. Materials and Method: The stability of dental implants was measured in 50 implants in a total of 38 patients. Measurements were performed using Anycheck and Periotest M devices, twice in total, divided into buccal and lingual directions. In addition, measurements were performed on the day of surgery, two weeks, one month, two months, and three months after surgery for a total of five times. After the standardization of the measured values, the differences and changes over time for each device were observed. Result: No difference in standardized values between the two devices was observed at any time point. In both devices, stability decreased at two weeks postoperatively but gradually increased thereafter. No differences were observed in the values according to the measurement direction. Conclusions: The damping capacity of Anycheck was similar to that of Periotest M. After a slight decrease in stability two weeks after implant placement, implant stability increased over time.