Yuli Sun Hariyani

Mrs. Yuli Sun Hariyani

Telkom University
+1
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
HEHeesang Eom
Heesang Eom
DLDongseok Lee
Dongseok Lee
Seungwoo HanSeungwoo Han
Seungwoo Han
Yuli Sun HariyaniYuli Sun Hariyani
Yuli Sun Hariyani
YLYonggyu Lim
Yonggyu Lim
CPCheolsoo Park
Cheolsoo Park
Blood pressure (BP) is a vital sign that provides fundamental health information regarding patients. Continuous BP monitoring is important for patients with hypertension. Various studies have proposed cuff-less BP monitoring methods using pulse transit time. We propose an end-to-end deep learning architecture using only raw signals without the process of extracting features to improve the BP estimation performance using the attention mechanism. The proposed model consisted of a convolutional neural network, a bidirectional gated recurrent unit, and an attention mechanism. The model was trained by a calibration-based method, using the data of each subject. The performance of the model was compared to the model that used each combination of the three signals, and the model with the attention mechanism showed better performance than other state-of-the-art methods, including conventional linear regression method using pulse transit time (PTT). A total of 15 subjects were recruited, and electrocardiogram, ballistocardiogram, and photoplethysmogram levels were measured. The 95% confidence interval of the reference BP was [86.34, 143.74] and [51.28, 88.74] for systolic BP (SBP) and diastolic BP (DBP), respectively. The R 2 values were 0.52 and 0.49, and the mean-absolute-error values were 4.06 ± 4.04 and 3.33 ± 3.42 for SBP and DBP, respectively. In addition, the results complied with global standards. The results show the applicability of the proposed model as an analytical metric for BP estimation.

1 April 2018 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
RAR. R. Adiputra
R. R. Adiputra
SHS. Hadiyoso
S. Hadiyoso
Yuli Sun HariyaniYuli Sun Hariyani
Yuli Sun Hariyani
This paper discusses a device for measuring oxygen saturation (SpO2) and heart rate as parameters of the representations of heart conditions. SpO2 device that have been made has a small dimension, wearable and high mobility with battery as the main power source. The device connects to a node MCU as a data processor and an internet network gateway to support internet of things applications. Data sent to the Internet cloud can be accessed online and real time via website for further analysis. The error rate at heart rate measurement is ± 2.8 BPM and for oxygen saturation (SpO2) is ± 1.5%. Testing data transmission delay until it can be displayed on website is 3 second that depends on internet traffic conditions.

10 January 2020 in IEEE Access
Verified
Journal Article
Open access
Yuli Sun HariyaniYuli Sun Hariyani
Yuli Sun Hariyani
HEHeesang Eom
Heesang Eom
CPCheolsoo Park
Cheolsoo Park
Automatic nailfold capillary segmentation is a challenging task owing to noise and large variabilities in images caused by insufficient focusing and low visibility of the capillaries. This task can be useful to detect and estimate the severity of autoimmune diseases of connective tissues or learning the status of white blood cells based on the cells’ blood flow on the nailfold capillary. Previous studies have addressed this task using manual, semi-automated, and automated segmentation method. However, further improvement is still required. With the recent progress of deep learning on medical imaging, we herein propose dual attention deep learning based on U-Net for nailfold capillary segmentation, named DA-CapNet. Our DA-CapNet improves the U-Net architecture by integrating a dual attention module that can capture a better representation of feature maps from input images. Furthermore, DA-CapNet is compared with three baselines: adaptive Gaussian algorithm, SegNet, the original U-Net. We experimentally demonstrate that our proposed method outperforms these baselines.

2 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Unang SunaryaUnang Sunarya
Unang Sunarya
Yuli Sun HariyaniYuli Sun Hariyani
Yuli Sun Hariyani
TCTaeheum Cho
Taeheum Cho
JRJongryun Roh
Jongryun Roh
JHJoonho Hyeong
Joonho Hyeong
CPCheolsoo Park
Cheolsoo Park
Gait analysis is commonly used to detect foot disorders and abnormalities such as supination, pronation, unstable left foot and unstable right foot. Early detection of these abnormalities could help us to correct the walking posture and avoid getting injuries. This paper presents extensive feature analyses on smart shoes sensor data, including pressure sensors, accelerometer and gyroscope signals, to obtain the optimum combination of the sensors for gait classification, which is crucial to implement a power-efficient mobile smart shoes system. In addition, we investigated the optimal length of data segmentation based on the gait cycle parameters, reduction of the feature dimensions and feature selection for the classification of the gait patterns. Benchmark tests among several machine learning algorithms were conducted using random forest, k-nearest neighbor (KNN), logistic regression and support vector machine (SVM) algorithms for the classification task. Our experiments demonstrated the combination of accelerometer and gyroscope sensor features with SVM achieved the best performance with 89.36% accuracy, 89.76% precision and 88.44% recall. This research suggests a new state-of-the-art gait classification approach, specifically on detecting human gait abnormalities.

25 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
HEHeesang Eom
Heesang Eom
JRJongryun Roh
Jongryun Roh
Yuli Sun HariyaniYuli Sun Hariyani
Yuli Sun Hariyani
Suwhan BaekSuwhan Baek
Suwhan Baek
SLSuk Ho Lee
Suk Ho Lee
CPCheolsoo Park
Cheolsoo Park
Wearable technologies are known to improve our quality of life. Among the various wearable devices, shoes are non-intrusive, lightweight, and can be used for outdoor activities. In this study, we estimated the energy consumption and heart rate in an environment (i.e., running on a treadmill) using smart shoes equipped with triaxial acceleration, triaxial gyroscope, and four-point pressure sensors. The proposed model uses the latest deep learning architecture which does not require any separate preprocessing. Moreover, it is possible to select the optimal sensor using a channel-wise attention mechanism to weigh the sensors depending on their contributions to the estimation of energy expenditure (EE) and heart rate (HR). The performance of the proposed model was evaluated using the root mean squared error (RMSE), mean absolute error (MAE), and coefficient of determination (R2). Moreover, the RMSE was 1.05 ± 0.15, MAE 0.83 ± 0.12 and R2 0.922 ± 0.005 in EE estimation. On the other hand, and RMSE was 7.87 ± 1.12, MAE 6.21 ± 0.86, and R2 0.897 ± 0.017 in HR estimation. In both estimations, the most effective sensor was the z axis of the accelerometer and gyroscope sensors. Through these results, it is demonstrated that the proposed model could contribute to the improvement of the performance of both EE and HR estimations by effectively selecting the optimal sensors during the active movements of participants.

11 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
BKByeonghwi Kim
Byeonghwi Kim
Yuli Sun HariyaniYuli Sun Hariyani
Yuli Sun Hariyani
YCYoung-Ho Cho
Young-Ho Cho
CPCheolsoo Park
Cheolsoo Park
White blood cells (WBCs) are essential components of the immune system in the human body. Various invasive and noninvasive methods to monitor the condition of the WBCs have been developed. Among them, a noninvasive method exploits an optical characteristic of WBCs in a nailfold capillary image, as they appear as visual gaps. This method is inexpensive and could possibly be implemented on a portable device. However, recent studies on this method use a manual or semimanual image segmentation, which depends on recognizable features and the intervention of experts, hindering its scalability and applicability. We address and solve this problem with proposing an automated method for detecting and counting WBCs that appear as visual gaps on nailfold capillary images. The proposed method consists of an automatic capillary segmentation method using deep learning, video stabilization, and WBC event detection algorithms. Performances of the three segmentation algorithms (manual, conventional, and deep learning) with/without video stabilization were benchmarks. Experimental results demonstrate that the proposed method improves the performance of the WBC event counting and outperforms conventional approaches.