Yunseo Ku

Prof. Yunseo Ku

Chungnam National University, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
JAJoong Woo Ahn
Joong Woo Ahn
YKYunseo Ku
Yunseo Ku
HKHee Chan Kim
Hee Chan Kim
Suffering from continuous stress can lead to serious psychological and even physical disorders. Objective stress assessment methods using noninvasive physiological responses such as heart rate variability (HRV) and electroencephalograms (EEG) have therefore been proposed for effective stress management. In this study, a novel wearable device that can measure electrocardiograms (ECG) and EEG simultaneously was designed to enable continuous stress monitoring in daily life. The developed system is easily worn by hanging from both ears, is lightweight (i.e., 42.5 g), and exhibits an excellent noise performance of 0.12 μVrms. Significant time and frequency features of HRV and EEG were found in two different stressors, namely the Stroop color word and mental arithmetic tests, using 14 young subjects. Stressor situations were classified using various HRV and EEG feature selections and a support vector machine technique. The five-fold cross-validation results obtained when using both EEG and HRV features showed the best performance with an accuracy of 87.5%, which demonstrated the requirement for simultaneous HRV and EEG measurements.

17 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Iqram HussainIqram Hussain
Iqram Hussain
Md Azam HossainMd Azam Hossain
Md Azam Hossain
Rafsan JanyRafsan Jany
Rafsan Jany
MBMd. Abdul Bari
Md. Abdul Bari
Musfik UddinMusfik Uddin
Musfik Uddin
JKJik-Soo Kim
Jik-Soo Kim
Electroencephalography (EEG) is immediate and sensitive to neurological changes resulting from sleep stages and is considered a computing tool for understanding the association between neurological outcomes and sleep stages. EEG is expected to be an efficient approach for sleep stage prediction outside a highly equipped clinical setting compared with multimodal physiological signal-based polysomnography. This study aims to quantify the neurological EEG-biomarkers and predict five-class sleep stages using sleep EEG data. We investigated the three-channel EEG sleep recordings of 154 individuals (mean age of 53.8 ± 15.4 years) from the Haaglanden Medisch Centrum (HMC, The Hague, The Netherlands) open-access public dataset of PhysioNet. The power of fast-wave alpha, beta, and gamma rhythms decreases; and the power of slow-wave delta and theta oscillations gradually increases as sleep becomes deeper. Delta wave power ratios (DAR, DTR, and DTABR) may be considered biomarkers for their characteristics of attenuation in NREM sleep and subsequent increase in REM sleep. The overall accuracy of the C5.0, Neural Network, and CHAID machine-learning models are 91%, 89%, and 84%, respectively, for multi-class classification of the sleep stages. The EEG-based sleep stage prediction approach is expected to be utilized in a wearable sleep monitoring system.

11 December 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JCJin Woo Choi
Jin Woo Choi
YKYunseo Ku
Yunseo Ku
BYByeong Wook Yoo
Byeong Wook Yoo
JKJung-Ah Kim
Jung-Ah Kim
DLDong Soon Lee
Dong Soon Lee
HKHee Chan Kim
Hee Chan Kim
The white blood cell differential count of the bone marrow provides information concerning the distribution of immature and mature cells within maturation stages. The results of such examinations are important for the diagnosis of various diseases and for follow-up care after chemotherapy. However, manual, labor-intensive methods to determine the differential count lead to inter- and intra-variations among the results obtained by hematologists. Therefore, an automated system to conduct the white blood cell differential count is highly desirable, but several difficulties hinder progress. There are variations in the white blood cells of each maturation stage, small inter-class differences within each stage, and variations in images because of the different acquisition and staining processes. Moreover, a large number of classes need to be classified for bone marrow smear analysis, and the high density of touching cells in bone marrow smears renders difficult the segmentation of single cells, which is crucial to traditional image processing and machine learning. Few studies have attempted to discriminate bone marrow cells, and even these have either discriminated only a few classes or yielded insufficient performance. In this study, we propose an automated white blood cell differential counting system from bone marrow smear images using a dual-stage convolutional neural network (CNN). A total of 2,174 patch images were collected for training and testing. The dual-stage CNN classified images into 10 classes of the myeloid and erythroid maturation series, and achieved an accuracy of 97.06%, a precision of 97.13%, a recall of 97.06%, and an F-1 score of 97.1%. The proposed method not only showed high classification performance, but also successfully classified raw images without single cell segmentation and manual feature extraction by implementing CNN. Moreover, it demonstrated rotation and location invariance. These results highlight the promise of the proposed method as an automated white blood cell differential count system.

1 July 2020 in IEEE Access
Verified
Journal Article
Open access
SKSoon Bin Kwon
Soon Bin Kwon
HHHyuk-Soo Han
Hyuk-Soo Han
MLMyung Chul Lee
Myung Chul Lee
HKHee Chan Kim
Hee Chan Kim
YKYunseo Ku
Yunseo Ku
DRDu Hyun Ro
Du Hyun Ro
Knee osteoarthritis (KOA) is a leading cause of disability among elderly adults, and it causes pain and discomfort and limits the functional independence of such adults. The aim of this study was the development of an automated classification model for KOA, based on the Kellgren–Lawrence (KL) grading system, using radiographic imaging and gait analysis data. Gait features highly associated with the radiological severity of KOA identified from our previous study, in addition to radiographic image features extracted from a deep learning network, namely, Inception-ResNet-v2, were exploited using a support vector machine for KOA multi-classification. The area under the curve (AUC) of the receiver operating characteristic curve from KL Grades 0–4 were 0.93, 0.82, 0.83, 0.88, and 0.97, respectively. The sensitivity, precision, and F1-score of the model were 0.70, 0.76, and 0.71, respectively. The proposed model outperformed a common deep learning approach that is based on using only radiographic images as the input data. This result indicates that gait data and radiographic images are complementary with respect to KOA classification, and the use of both data can improve the accuracy of the automated diagnosis of multiclass KOA.

9 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
JSJangjay Sohn
Jangjay Sohn
SYSeungman Yang
Seungman Yang
JLJoonnyong Lee
Joonnyong Lee
YKYunseo Ku
Yunseo Ku
HKHee Chan Kim
Hee Chan Kim
Reconstructing a standard 12-lead electrocardiogram (ECG) from signals received from electrodes packed into a patch-type device is a challenging task in the field of medical instrumentation. All attempts to obtain a clinically valid 12-lead ECG using a patch-type device were not satisfactory. In this study, we designed the hardware for a three-lead patch-type ECG device and employed a long short-term memory (LSTM) network that can overcome the limitations of the linear regression algorithm used for ECG reconstruction. The LSTM network can overcome the issue of reduced horizontal components of the vector in the electric signal obtained from the patch-type device attached to the anterior chest. The reconstructed 12-lead ECG that uses the LSTM network was tested against a standard 12-lead ECG in 30 healthy subjects and ECGs of 30 patients with pathologic findings. The average correlation coefficient of the LSTM network was found to be 0.95. The ability of the reconstructed ECG to detect pathologic abnormalities was identical to that of the standard ECG. In conclusion, the reconstruction of a standard 12-lead ECG using a three-lead patch-type device is feasible, and such an ECG is an equivalent alternative to a standard 12-lead ECG.

1 April 2018 in Electronics Letters
Verified
Journal Article
Open access
PDF file
JAJ.W. Ahn
J.W. Ahn
YKYunseo Ku
Yunseo Ku
DKD.Y. Kim
D.Y. Kim
JSJ. Sohn
J. Sohn
JKJ.‐H. Kim
J.‐H. Kim
HKHee Chan Kim
Hee Chan Kim
Steady‐state visual evoked potential (SSVEP) has been widely used in electroencephalogram (EEG)‐based brain–computer interfaces (BCIs) due to its high information transfer rate (ITR) and short training time. Current methods usually measure SSVEP from electrodes on the scalp, which is an uncomfortable and time‐consuming method. Furthermore, most research relies on expensive and non‐portable EEG devices. To utilise BCIs in daily life, however, these are critical issues to address. Hence, a wearable EEG device for in‐ear SSVEP detection is proposed. The system is 40 × 21 × 10.5 mm 3 and weighs 14.2 g, thus being light weight and wearable. Moreover, the system has a noise level of 0.11 µV rms , which is comparable with commercial EEG systems. Six subjects participated in an offline BCI experiment that consisted of six visual targets using the developed in‐the‐ear EEG system. The results showed a highest ITR of 11.03 ± 4.18 bits/min with an accuracy of 79.9 ± 13.1%, and the experiments demonstrated that the system can be utilised for unobtrusive monitoring of SSVEP in BCI applications.