Using a data-driven framework, we examined when recorded older-adult metro activity occurs and whether detailed spatial measures predict station activity better than simple contextual variables. The data comprise 22,908,241 recorded entry and exit events from age-65+ fare-exempt cards at 263 Chongqing metro stations in March 2025, aggregated by station and clock hour. We characterized entry–exit directionality and modelled total and population-adjusted activity using older-population catchments, points of interest (POIs), metro topology, pedestrian networks, and route-level terrain. Predictive comparisons used geographically blocked cross-validation, with all preprocessing and tuning confined to the training data. Entry and exit counts showed clear temporal and spatial differences, although net inflow prediction transferred poorly to held-out areas (out-of-fold R2 = −0.099 to 0.042). Population aged 65+ and transfer status supplied most of the transferable signal (out-of-fold R2 = 0.472). POIs added little (ΔR2 = 0.007), while richer spatial representations did not improve held-out prediction. Thirty repeated geographic partitions confirmed a small average advantage for the POI-augmented model but also showed sensitivity to the partition. These findings support parsimonious station activity modelling. A complementary screening analysis defined a reproducible 45-station pool for targeted access audits.
Accurate module-temperature estimation supports assessment of rooftop photovoltaic (PV) systems, but minute-scale meteorological fluctuations and thermal memory challenge steady-state models. This study used 44,638 synchronized one-minute records from a rooftop PV platform in Chongqing, China, during August 2025. The representative backsheet temperature was the arithmetic mean of five simultaneously valid sensors. Physical, static XGBoost, and thermal-history-aware XGBoost models were compared. Lagged values, strictly prior rolling means, and increments were constructed uniformly for four meteorological variables at 5, 10, and 20 min windows. Three expanding-time validation folds and a one-standard-error parsimony rule selected eight features: four current variables and their strictly prior 10 min means. During the retrospective 27–31 August held-out comparison, the dynamic-model MAE was slightly higher than the static-model MAE (1.088 versus 1.081 °C). RMSE decreased from 1.757 to 1.437 °C and P95AE from 3.907 to 3.049 °C. Paired day-level bootstrap intervals supported the observed tail-error reduction more clearly than the RMSE difference within this five-day record. MAE was about 40% lower during severe ambient heat and 45% lower during rapid irradiance decrease but increased at night. Daily peaks were underestimated by 2.574 °C on average; absolute peak-timing error had a mean of 26.8 min and a median of 1 min. The findings support site-specific thermal-history features for estimating the monitored-point mean, not a universal thermal timescale or uncalibrated safety-related peak thresholding. Prior inspection of the comparison dates, limited temporal coverage, and absent external validation restrict transferability.
With ongoing urban warming and the increasing frequency of extreme heat events, thermal comfort at highly exposed public spaces like bus stops has attracted significant attention. However, existing studies largely rely on linear assumptions and limited environmental variables, leaving the complex, multidimensional mechanisms driving thermal perception unclear. This study investigates the nonlinear impacts of microclimate, urban morphology, and station design on passengers’ thermal perception during summer in Chongqing, China. Drawing on field measurements, questionnaire surveys, and spatial data, linear regression was first applied to estimate neutral temperatures and acceptable thermal ranges. Subsequently, an interpretable machine learning framework integrating XGBoost and SHAP analysis was developed to explore the nonlinear effects and interactions mechanisms among these variables. The results reveal a dual regulatory pattern. Mechanism variables exhibit distinct nonlinear thresholds, with wind speeds above 0.98 m/s showing cooling associations and PET values exceeding 34.70 °C corresponding to more rapid increases in thermal discomfort. Concurrently, urban morphology and station design factors contextually modify these direct effects by altering their magnitude and direction. Furthermore, significant spatial heterogeneity in thermal adaptation was observed, with neutral temperatures ranging from 23.19 to 31.01 °C. These findings provide a basis for developing adaptive and context-specific thermal environment management strategies for urban bus stops.