Accurate ranging and real-time temperature monitoring are essential for metrology and safety in electrical conduit applications. This paper proposes an acoustic time-of-flight (TOF) estimation method based on the digital lock-in filtering (DLF) technique for conduit ranging and thermometry. The method establishes the relationship between the frequency and the time domain by applying a linear frequency modulated Chirp signal as the sound source and using the DLF technique to extract the first harmonic of the characteristic frequencies of the transmitted and received signals. Acoustic TOF estimation in the conduit is then achieved by calculating the mathematical expectation of the time difference between each characteristic frequency in the time-frequency relationship of the two signals. The experimental results with enhanced noise interference on different conduit lengths and various temperature conditions, proved that the proposed DLF method can establish a robust linear time-frequency relationship according to the characteristics of the Chirp signal, and the measurement accuracy of TOF has also been confirmed. Compared to the conventional method, the DLF method provides the lowest absolute error and standard deviation for both distance and temperature measurements with an enhanced robustness.
A simple approximation scheme to describe the half width of the Voigt profile as a function of the relative contributions of Gaussian and Lorentzian broadening is presented. The proposed approximation scheme is highly accurate and provides an accuracy better than 10−17 for arbitrary αL/αG ratios. In particular, the accuracy reaches an astonishing 10−34 (quadruple precision) in the domain 0 ≤ αL/αG ≤ 0.2371 ∪ αL/αG ≥ 33.8786.
Laser absorption spectroscopy tomography is an effective combustion diagnostic method for obtaining simultaneous two-dimensional distribution measurements of temperature and gas molar concentrations. For the reconstruction process of complex combustion flames, a new algorithm named ‘multi-iterative adaptive optimization regularization’ (MIARO) is proposed. This algorithm is a further development of another algorithm known as the ‘modified adaptive algebraic reconstruction technique’ (MAART) with the improvement of the initial value and adaptive regularization parameter selections. In MIARO, the problem of the MAART’s initial value sensitivity is compensated for, and in addition, reconstruction parameters are also introduced into the regularization so that both the quality of reconstruction and the convergence of regularization are guaranteed. In butane burner experiments, an average relative error of 1.82% was achieved with MIARO, compared to 2.44% with MAART, which is a significant reduction of 25.1%. The simulation and experimental results clearly demonstrate that the MIARO algorithm can be used to reconstruct dynamic combustion fields and eliminate boundary artifacts with improved measurement accuracy and robustness.
A rapidly convergent series, based on Taylor expansion of the imaginary part of the complex error function, is presented for highly accurate approximation of the Voigt/complex error function with small imaginary argument y ≤ 0.1. Error analysis and run-time tests in double-precision arithmetic reveals that in the real and imaginary parts, the proposed algorithm provides an average accuracy exceeding 10−15 and 10−16, respectively, and the calculation speed is as fast as that reported in recent publications. An optimized MATLAB code providing rapid computation with high accuracy is presented.
31 October 2023 in Thermal Science and Engineering Progress
Methane is the second most important anthropogenic greenhouse gas after carbon dioxide, and its accurate measurement is essential for climate monitoring. In this work, a laser-locked cavity ring-down spectroscopy (LL-CRDS) system was developed for continuous atmospheric methane measurements. By locking the laser frequency to a longitudinal mode of the optical cavity, long-term wavelength stability was achieved, enabling highly stable methane measurements. Laboratory tests demonstrated a precision of 0.4 ppb at an integration time of 3.6 s, a minimum Allan deviation of 0.3 ppb at 15 s, and long-term stability better than 23 ppb over one month without recalibration. Field measurements with a commercial CRDS analyzer showed excellent agreement, with an average deviation of 1.4 ppb. These results demonstrate the suitability of LL-CRDS for long-term atmospheric methane monitoring requiring high precision and low maintenance.