27 April 2023 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
XLxinyu liu
xinyu liu
HXHuanhai Xin
Huanhai Xin
DZDi Zheng
Di Zheng
DCDong Chen
Dong Chen
JTJingzhe Tu
Jingzhe Tu
Deployment of Synchronous Condensers (SynCons) has become one popular solution in accommodating large-scale renewable energy source (RES) for existing power systems. However, as a rotating device, SynCon may lose transient rotor angle stability caused by injected active power from nearby RES after a fault. To reveal this phenomenon, the transient stability of SynCon is investigated in this article. To derive intuitive mechanism and assist quantitative analysis, the equivalent synchronous generators (ESG) model is proposed to characterize the transient behavior of SynCon and co-located RES. The Lyapunov's direct method is employed for the assessment of transient stability by analyzing attraction domain for a typical benchmark system. On this basis, an index of transient stability margin against grid strength and an adaptive low voltage ride through (LVRT) control strategy are proposed for further assessment and enhancement of transient stability. The accuracy and effectiveness of the proposed methods are verified with EMT simulations of a typical windfarm configuration.

2 February 2023 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
HXHuanhai Xin
Huanhai Xin
XLxinyu liu
xinyu liu
DZDi Zheng
Di Zheng
DCDong Chen
Dong Chen
YZYuhan Zhou
Yuhan Zhou
BMBenjamin Marshall
Benjamin Marshall
Temporary overvoltage (TOV) is becoming one challenge for the integration of significant power electronics resources into a power system. To assess the risk of TOV in a Multi-Infeed Power Electronic System (MIPES), a worst-case estimation approach is proposed to assess TOV risk. The paper starts with analyzing the mechanism of TOV, which reveals that TOV is dominated by excessive reactive power resulting from comprehensive control laggings. Then, the principle of approximating the TOV for a Voltage Source Converter (VSC) connecting to an infinite bus is introduced within the context of the RMS model. After that, a method based on the concept of generalized short-circuit ratio for overvoltage (gSCR-TOV) is introduced to quantify the risk of TOV in a multi-bus system. This concept intends to permit screening to identify those nodes at greatest need for further EMT assessment. To localize these nodes, a concept of weighted sensitivity matrix is further proposed to pinpoint the bus subject to highest TOV in a MIPES. Finally, case studies of EMT time-domain simulations are carried out and verifies the effectiveness of the proposed methods.

5 February 2025 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
XLxinyu liu
xinyu liu
JHJierui Huang
Jierui Huang
DZDi Zheng
Di Zheng
HXHuanhai Xin
Huanhai Xin
TBTianshu Bi
Tianshu Bi
Temporary overvoltage (TOV) severely restricts the development and utilization of renewable power resources (RPRs), especially when RPRs are delivered through the line commutated converter-based high voltage direct current (LCC-HVDC) system. To reveal the TOV mechanism for the sending system during commutation failures (CFs), the transient process of the system is partitioned into different stages, where the evolution of the system trajectories is analyzed. On this basis, the variation of AC voltage and DC current considering complex dynamic interactions between LCC-HVDC and renewable energy Plants (REPs) during repetitive CFs (RCFs) is clearly quantified. After revealing the impact of control parameters of both REPs and the LCC-HVDC on the TOV during RCFs, a collaborative optimization method for control parameters is proposed for TOV suppression. Moreover, when the blocking after the RCF tends to be inevitable, the optimal blocking moment is determined to inhibit the TOV caused by HVDC blocking. The accuracy and effectiveness of the proposed methods are verified with EMT simulations of a typical benchmark system.

12 September 2023 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
XLXinyu Liu
Xinyu Liu
HXHuanhai Xin
Huanhai Xin
DZDi Zheng
Di Zheng
BCBin Cao
Bin Cao

16 July 2024 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
XLxinyu liu
xinyu liu
HXHuanhai Xin
Huanhai Xin
YSYongpeng Shan
Yongpeng Shan
DZDi Zheng
Di Zheng
DCDong Chen
Dong Chen
Synchronous condensers (SynCons) are widely used in supporting the integration of renewable power plants (RPPs) in weak grids. However, recent research suggests that a SynCon co-located with RPPs may be prone to transient rotor angle instability due to the excessive active power injected by nearby RPPs during metallic faults. This paper further discovers that the transient stability of the SynCon may be lost even it generates electrical power during high-resistance faults. This novel mechanism of instability is investigated by deriving power-angle characteristics in different fault scenarios, and then the effect of the system parameters on the stability is analyzed via a proposed index based on the critical clearance time (CCT). It reveals that inappropriate parameters of SynCons, weak grid, and voltage support during fault ride-through (FRT) all contribute to such transient instability. To mitigate such instability, an adaptive FRT strategy is proposed. The electromagnetic transient (EMT) simulations based on the PSCAD are carried out to validate the effectiveness of the theoretical analysis and the proposed adaptive control strategy.

6 March 2019 in IEEE Access
Verified
Journal Article
Open access
JOJinxin Ouyang
Jinxin Ouyang
ZZZhen Zhang
Zhen Zhang
TTTing Tang
Ting Tang
MPMingyu Pang
Mingyu Pang
MLMengyang Li
Mengyang Li
DZDi Zheng
Di Zheng
With a high proportion of wind power being transmitted through AC and DC lines, a new power grid pattern has gradually emerged. A DC inverter is prone to commutation failure, which may lead to cascading trip of AC lines for overload, resulting in serious consequences. However, existing control methods have problems of over-or under-shedding and are unsuitable for high-proportion wind power transmission systems. Accordingly, a new fault overload control method based on emergency acceleration of doubly-fed induction generator (DFIG) is proposed. The fast power control capability of DFIG is fully utilized, the active power of power grid could be rapidly balanced. First, the fault characteristics of a wind power AC/DC transmission system under the fault of DC receiving-end grid are analyzed, and the power flow transfer after self-recovery from the DC commutation failure is derived. Second, by analyzing the power characteristics of DFIG, a fault overload control idea of the wind power transmission system is proposed based on emergency acceleration of DFIG. Lastly, the maximum controllable capacity of a wind farm is analyzed, and a fault overload control strategy of the wind power transmission system is proposed. Simulation results prove that the proposed method can rapidly reduce the output of wind farms and prevent the overload of AC lines.