This paper presents coordinated power management strategies for a hybrid electric boat (HEB) based on dynamic load's power distribution approach using diesel generators and batteries. Two variable-speed diesel generator sets connecting to dc-bus via fully controlled rectifiers serve as the main power supply source; one lithium-battery pack linked to dc-bus through a bidirectional DC/DC converter serves as an auxiliary power supply source. The power requirement of the thrusters and other onboard equipment is represented by a load power profile. The main contribution of this paper is focused on the load power sharing of the HEB between the two variable-speed diesel generators and the lithium-battery pack, through the fluctuations extracted from load power and their assignation to the batteries. Another important issue is that when the total load demand is low, one of the diesel generator set will be switched off to improve the diesel-fuel efficiency. The output powers of the diesel generators and the batteries are controlled based on the power distribution strategy via the converters controlling. The performances of the proposed hybrid power system control are evaluated through simulations in MATALB/Simulink, and through reduced-scale experimental tests carried out for a specific driving cycle of the HEB.
The selection of electric machines for an Electric Vehicle (EV) is mainly based on reliability, efficiency, and robustness, which makes the 5-phase Permanent Magnet Synchronous Motor (PMSM) among the best candidates. However, control performance of any motor drive can be deeply affected by both: (1) internal disturbances caused by parametric variations and model uncertainties and (2) external disturbances related to sensor faults or unexpected speed or torque variation. To ensure stability under those conditions, an Active Disturbance Rejection Controller (ADRC) based on an online dynamic compensation of estimated internal and external disturbances, and a Linear ADRC (LADRC) are investigated in this paper. The control performance was compared with traditional controller and evaluated by considering parametric variation, unmodeled disturbances, and speed sensor fault. The achieved results clearly highlight the effectiveness and high control performance of the proposed ADRC-based strategies.
This study mainly investigates the current and speed control strategies of a doubly-fed induction generator (DFIG), which is applied to a tidal stream turbine (TST). Indeed, DFIG using integer-order PI (IOPI) controller has been widely proposed in the applications with a similar system, especially in wind energy conversion system (WECS). However, these conventional controllers cannot deal with the problems caused by the parameter variations satisfactorily under complex and harsh operation conditions, and may even deteriorate the performance. As a result, a fractional-order PI (FOPI) controller is considered to improve the efficiency and performance of DFIG-based TST in this paper. The FOPI controller, developed from the traditional IOPI controller and the fractional calculus theory, has a lot of prominent merits in many aspects, such as robustness, stability, and dynamic performance. In this paper, the proposed control strategies are embedded into the whole TST model which contains the tidal stream turbine, and the generator. The obtained simulation results demonstrate the prominent effectiveness and advantages of the proposed strategies compared with the conventional IOPI controller in terms of overshoot, static error, adjustment time, and robustness. It implies that FOPI controller could be a good candidate in TST applications.
Flywheel is a promising energy storage system for domestic application, uninterruptible power supply, traction applications, electric vehicle charging stations, and even for smart grids. In fact, recent developments in materials, electrical machines, power electronics, magnetic bearings, and microprocessors offer the possibility to consider flywheels as a competitive option for electric energy storage, which can be of great interest for domestic applications in the near future. In this paper, a grid-tied flywheel-based energy storage system (FESS) for domestic application is investigated with special focus on the associated power electronics control and energy management. In particular, the overall PMSM-based flywheel configuration is reviewed and a controlling strategy was experimentally implemented using DS1104 controller board from dSPACE. Two case studies were considered for power peak shaving and power backup at domestic level. A lab-scale prototype was built to validate the proposal. The achieved results are presented and discussed to demonstrate the possibilities offered by such an energy storage system for domestic application.
26 May 2025 in Energy Conversion and Management: X
This article deals with the techno-economic optimal sizing of a tidal stream turbine (TST)–battery system. In this study, the TST system consists of a turbine rotor and a permanent magnet synchronous generator (PMSG) associated with a three-phase converter coupled to a DC bus. A battery is used within the system as an energy storage system to absorb excess produced power or cover power deficits. To determine the optimal sizing of the system, an iterative approach was used owing to its ease of implementation, high accuracy, and fast convergence speed, even under environmental constraints such as swell and wave effects. This technique is based on robust energy management, and the recursive algorithm includes the deficiency of power supply probability (DPSP) and the relative excess power generation (REPG) as technical criteria for the system reliability study, and the energy cost (EC) and the total net present cost (TNPC) as economic criteria for the system cost study. As data inputs, the proposed approach used the existing data from the current speed profile, the load, and economic parameters. The desired output is the system component optimal sizing (TST power, and battery capacity). In this paper, the system sizing was studied during a one-year time period to ensure a more reliable and economical system. The results are compared to well-known methods such as genetic algorithms, particle swarm optimization, and software-based (HOMER) approaches. The optimization results confirm the efficiency of the proposed approach in sizing the system, which was simulated using real-world tidal velocity data from a specific deployment site.