Ozonation followed by biological post-treatment is an established technology for abatement of organic micropollutants (OMP) from municipal wastewater. Although the necessity of biological post-treatment for oxidation by-product (OBP) removal is widely accepted, there is still discussion about the appropriate design and operation. The presented pilot-study investigates the impact of filter material and contact time on the removal efficiency of bulk organics, OMP, and OBP in three different deep-bed filters operated in parallel as post-treatment after ozonation (biological activated carbon (BAC) filter, dual-media filter sand/BAC and dual-media filter sand/anthracite). The use of BAC instead of non-adsorptive filter material resulted in higher removal of DOC and dissolved oxygen which indicates increased biological activity. Moreover, both BAC containing filters showed additional removal for a number of OMP even at high treated bed volumes of >50 000 whereas no removal was observed in the sand/anthracite filter. Analysis of N-nitrosodimethylamine (NDMA) and several carbonyl compounds revealed a clear formation of these biodegradable OBP during ozonation. A strong correlation was found between carbonyl formation and the specific ozone dose. Removal of OBP in the sand/BAC and the sand/anthracite filter was tested at different empty bed contact times (EBCT). While NDMA was efficiently removed independent of EBCT changes, there was a slightly negative impact of shorter EBCT on the reduction of carbonyl compounds. Furthermore, it was demonstrated that the integration of enhanced phosphorus removal into post-treatment is feasible with relatively low efforts by inline coagulant dosing (FeCl3) in the filter influent.
Wastewater-based SARS-CoV-2 epidemiology (WBE) has been established as an important tool to support individual testing strategies. The Omicron sub-variants BA.4/BA.5 have spread globally, displacing the preceding variants. Due to the severe transmissibility and immune escape potential of BA.4/BA.5, early monitoring was required to assess and implement countermeasures in time. In this study, we monitored the prevalence of SARS-CoV-2 BA.4/BA.5 at six municipal wastewater treatment plants (WWTPs) in the Federal State of North Rhine-Westphalia (NRW, Germany) in May and June 2022. Initially, L452R-specific primers/probes originally designed for SARS-CoV-2 Delta detection were validated using inactivated authentic viruses and evaluated for their suitability for detecting BA.4/BA.5. Subsequently, the assay was used for RT-qPCR analysis of RNA purified from wastewater obtained twice a week at six WWTPs. The occurrence of L452R carrying RNA was detected in early May 2022, and the presence of BA.4/BA.5 was confirmed by variant-specific single nucleotide polymorphism PCR (SNP-PCR) targeting E484A/F486V and NGS sequencing. Finally, the mutant fractions were quantitatively monitored by digital PCR, confirming BA.4/BA.5 as the majority variant by 5 June 2022. In conclusion, the successive workflow using RT-qPCR, variant-specific SNP-PCR, and RT-dPCR demonstrates the strength of WBE as a versatile tool to rapidly monitor variants spreading independently of individual test capacities.
30 July 2024 in Journal of Environmental Management
When water supply restrictions increasingly escalate to water supply risks, developing strategies to minimize the water footprint of wet cooling systems becomes crucial. This study compares two water engineering approaches to minimize the water footprint of a recirculating evaporative cooling tower (CT): (1) reusing cooling tower blowdown and (2) producing demineralized water to increase the cycles of concentration (CoC) of the CT. Our techno-economic analysis across various scenarios and CT settings reveals that reusing blowdown (option 1) is the most feasible approach for an industrial cooling system currently operating at CoCs of > 3, discharging blowdown with a conductivity of 2 mS/cm and a total organic carbon (TOC) concentration of approximately 20 mg/L. Compared to enhanced make up treatment, blowdown reuse allows higher water savings (13 %) and involves lower implementation and operation costs. Pilot scale trials validated the feasibility of both approaches. Blowdown and enhanced make up treatment included biologically activated carbon filtration, ultrafiltration and reverse osmosis, producing high-quality permeate, suitable for (re)use as CT make up or within other processes. The blowdown treatment reached a product quality of 80 μS/cm conductivity and 70 μg/L TOC, make up treatment 20 μS/cm in conductivity and 60 μg/L TOC, respectively. The study's findings underscore the viability of blowdown reuse as a cost-effective and efficient strategy to minimize the water footprint of cooling systems under increasing water scarcity conditions.