In Belgium, and many other countries, rooftop solar panels are becoming a ubiquitous form of decentralised energy production. The increasing share of these distributed installations however imposes many challenges on the operators of the low-voltage distribution grid. They must keep the voltage levels and voltage balance on their grids in check and are often regulatory required to provide sufficient reception capacity for new power producing installations. By placing solar panels in different inclinations and azimuth angles, power production profiles can possibly be shifted to align more with residential power consumption profiles. In this article, it is investigated if the orientation of solar panels can have a mitigating impact on the integration problems on residential low voltage distribution grids. An improved simulation model of a solar panel installation is constructed, which is used to simulate the impact on a residential distribution grid. To stay as close to real-life conditions as possible, real irradiation data and a model of an existing grid are used. Both the developed model as the results on grid impact are evaluated.
The increased utilisation of distributed renewable energy sources in low voltage grids leads to power quality problems such as overvoltages and voltage unbalance. This imposes challenges to the distribution system operators to maintain the power quality in their grids. To overcome these issues, energy storage systems could be integrated together with the distributed energy resources and the stored energy could be used when needed to better improve power quality and achieve better grid performance. However, integrating an energy storage system introduces additional cost, therefore, determining the right capacity is essential. In this article, an energy storage system is combined with the classical positive-sequence control strategy and the three-phase damping control strategy. The three-phase damping control strategy is able to mitigate the voltage unbalance by emulating a resistive behaviour towards the zero- and negative-sequence voltage components. This resistive behaviour can be set on different values such that the desired voltage unbalance mitigation is achieved. Hence, the three-phase damping control strategy, equipped with the energy storage system is investigated under different values of the resistive behaviour. Both control strategies are investigated under the same conditions and the impact of the different capacities of the energy storage systems is investigated.
The constantly decreasing prices of the battery storage systems make them a very attractive solution for mitigating over voltages and voltage unbalance in low voltage grids with high penetration of renewable energy resources. A centralised storage device, connected at the end of the feeder can be a very effective solution for dealing with over voltages. The classical positive-sequence control strategy is usually employed in these devices to ensure a power exchange between the grid and the battery and vice versa. Nevertheless, the voltage unbalance cannot be mitigated by the classical control strategies. In this article, a modified three-phase damping control strategy is used to discharge and charge the battery storage system. This control strategy has an improved resistive behavior towards the zero- and negative-sequence components which mitigates the voltage unbalance by injecting or drawing asymmetrical phase currents. Thus both power quality problems are mitigated.
The share of renewable energy is increasing because of environmental concerns and favorable economic conditions. The majority of the distributed energy resources, connected to the low-voltage grid, are inverter-connected units. These inverters are controlled by using specially developed control strategies to determine the power injection between the primary source and the grid. In the past, the connection of distributed energy resources was based on the connect-and-forget principle, but this approach leads to severe power quality problems. Nowadays, more sophisticated control strategies need to be developed, so that ancillary services can be provided to the distribution system operator, which will allow further increase of renewable share in the distribution grids. This article examines the technical capabilities of the three-phase damping control strategy to provide ancillary services to the distribution system operator. Besides the three-phase damping control strategy, the article also compares the classical positive-sequence control strategy. Active power drooping and reactive power exchange are combined with these control strategies and the effect on the annual energy production, power quality, and grid performance is assessed. The simulations are conducted on a Matlab/OpenDSS platform in a time series simulations.
During the past years, a large amount of photovoltaic (PV) capacity has been installed in Belgium. The main driver for this was the abundant government support (Green Power Certificates). However, during the last few years, the support for new installations has been withdrawn and new PV capacity ceased. In previous research, it has been proven that selling PV energy of existing plants directly on the wholesale market is not feasible due to the large share of green power certificates awarded to these plants. However, the price of green power certificates has dropped significantly and hence the balance between certificate and commodity revenue is restored. This paper investigates the risks and challenges of leaving the fixed rate system and trade directly on the more volatile day ahead markets while facing penalties resulting from wrong forecasts. It will be proven that nominating to much or not enough energy can be positive, but also yield large risks.