Radiative thermal management technologies that utilize thermal radiation from nano/microstructure for cooling and heating have gained significant attention in sustainable energy research. Passive radiative cooling and solar heating operate continuously, which may lead to additional heating or cooling energy consumption due to undesired cooling or heating during cold nighttime/winters or hot daytime/summers. To overcome the limitation, recent studies have focused on developing radiative thermal management technologies that can toggle radiative cooling on and off or possess switchable dual cooling and heating modes to realize sustainable and efficient thermal management. This review will explore the fundamental concepts of radiative thermal management and its switching mechanisms, utilizing novel systems composed of various materials and nano/microstructures. Additionally, we will delve into the potential future research directions in radiative thermal management technologies.
Ion traps can provide both physical implementation of quantum information processing and direct observation of quantum systems. Recently, surface ion traps have been developed using microfabrication technologies and are considered to be a promising platform for scalable quantum devices. This paper presents detailed guidelines for designing the electrodes of surface ion traps. First, we define and explain the key specifications including trap depth, q-parameter, secular frequency, and ion height. Then, we present a numerical-simulation-based design procedure, which involves determining the basic assumptions, determining the shape and size of the chip, designing the dimensions of the radio frequency (RF) electrode, and analyzing the direct current (DC) control voltages. As an example of this design procedure, we present a case study with tutorial-like explanations. The proposed design procedure can provide a practical guideline for designing the electrodes of surface ion traps.
We present a numerical study of a microelectromechanical-system-based design of a fiber cavity integrated with an ion-trap system. Each fiber mirror is supported by a microactuator that controls the mirror’s position in three dimensions. The mechanical stability is investigated by a feasibility analysis, which shows that the actuator offers stable support of the fiber. The actuators move the fibers’ positions continuously with a stroke of more than , with mechanical resonance frequencies on the order of kilohertz. A calculation of the trapping potential shows that a separation between the ion and the fiber consistent with strong ion-cavity coupling is feasible. Our miniaturized ion-photon interface constitutes a viable approach to integrated hardware for quantum information.
A novel microfabricated ion trap chip that can geometrically minimize exposing trapped ions to stray charges on dielectric surfaces is developed. The new design utilizes a sloped loading slot to make the dielectric layers of the loading slot sidewalls invisible to the trapped ions. The designed loading slot is realized by applying silicon anisotropic etching processes, and the ion trap chip that contains the sloped loading slot is fabricated using microelectromechanical system processes. Stray charges induced by injecting an ultraviolet laser on the surface of the fabricated ion trap chip are experimentally characterized by measuring stray electric fields at the location of the trapped ions. The measured results are compared to those of a previous ion trap chip with a vertical loading slot. The magnitude of the measured stray electric field in the axial direction is within 1.5 V m−1 for the proposed ion trap chip, whereas it is approximately 10 V m−1 for the previously reported ion trap chip.
1 February 2021 in Japanese Journal of Applied Physics
A large-scale ion trap array fabricated using the microelectromechanical systems (MEMS) technology is expected to be a promising device for building a practical quantum computer. Shuttling trapped ions is essential for operating scalable ion trap structures. This paper proposes an ion shuttling method for a MEMS-fabricated surface ion trap. Change of secular frequency of trapping potential can cause heating and subsequent loss of ions. Therefore, direct current voltage sets to form uniform ion trapping potentials around the ions while shuttling are calculated by simulations. A 32-channel digital-to-analog converter system is developed to apply the calculated voltage sets to the electrodes of the MEMS-fabricated surface ion trap. The shuttling process is experimented using trapped 174Yb+ ions. The successful round trip of the ion for 1920 μm is demonstrated using the developed approach.
P-type silicon nanowires (SiNWs) have attracted significant attention for their potential in miniaturizing sensing devices, attributed to the observed giant piezoresistive (PZR) effects. However, the application of these advantageous PZR properties of SiNWs to microelectromechanical systems (MEMS) has been hindered by unclear noise levels and complicated fabrication methods. Additionally, several previous reports of anomalous PZR effects, such as doping-type inversion in hydrogen fluoride (HF)-treated p-type SiNWs, have introduced further complexities. Consequently, addressing these unclear challenges is necessary to effectively utilize the PZR effects of SiNWs for MEMS sensing applications. In this paper, the primary causes of uncertain noises and resistance levels in HF-treated p-SiNWs and their dependence on surface effects were analyzed to optimize NW parameters. SiNWs were fabricated using a suitable MEMS fabrication method, and their noises with PZR effects were measured and compared. The results indicated that SiNWs with abnormal PZR characteristics were worse in signal-to-noise ratio (SNR) than those with bulk PZR properties attributed to the significant noise increments from the depletion effects. Based on the NW experiment and additional mechanical analyses, suitable SiNW conditions for MEMS sensing unit were optimized and selected. A miniaturized 3-axis accelerometer utilizing the optimized SiNW was developed and tested. The experimental results showed that the developed accelerometer successfully reduced the total area of the sensor structure by 35.4% when compared to commercial capacitive accelerometers while maintaining competitive performance. This result was achieved without relying on the giant or anomalous PZR effects.