Ernest Stano

Dr. Ernest Stano

Institute of Mechatronics and Information Systems, Lodz University of Technology
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2020 in IEEE Access
Verified
Journal Article
Open access
Michal KaczmarekMichal Kaczmarek
Michal Kaczmarek
ESErnest Stano
Ernest Stano
The novelty of the paper contributes to the increase of the reliability of the methods used for evaluation of the inductive CTs accuracy of transformation of the distorted current. The results of performed analyses shows that the values of current and phase errors of transformation of the low order higher harmonics by inductive CT depends significantly from the phase angle between transformed higher harmonics of the distorted primary current and the self-generated higher harmonics of the secondary current. Moreover, higher harmonics of the distorted primary current may increase the peak value of the magnetic flux density in the magnetic core. Then the impact of the self-generated low order harmonics resulting from the nonlinearity of the magnetic core on values of current and phase errors of transformation of the higher harmonics of the distorted primary current is increased. Proposed evaluation procedure enables determination of the maximum values of current and phase errors of transformation of the higher harmonics of the distorted primary current. It is essential to determine the accuracy class. In such approach the impact of the secondary current’s distortion caused by the nonlinearity of the magnetic core and the influence of the harmonic distortion on the peak value of the magnetic flux density are considered. Therefore, transformation accuracy of tested CT is ensured for specified range and type of the load of the secondary winding, rms values of primary current and its distortion.

1 December 2019 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
Michal KaczmarekMichal Kaczmarek
Michal Kaczmarek
ESErnest Stano
Ernest Stano


11 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ESErnest Stano
Ernest Stano
Michal KaczmarekMichal Kaczmarek
Michal Kaczmarek
Self-calibration of a designed wideband inductive current transformer (CT) was carried out in the ampere-turns condition. This method does not require a reference transducer. The values of current and phase errors at the harmonics of frequencies from 100 Hz to 5 kHz were determined for the distorted primary current of the rated main frequency equal to 50 Hz. These results were verified based on the comparison of values measured between two CTs and calculated as the difference between values obtained from their calibration. Moreover, from vectorial diagrams drawn for transformation of the higher harmonics, the source of the change in the values of current and phase errors with frequency is explained. Furthermore, the method for calculation of the values of the corresponding harmonics of the current associated with the active power losses in the core and the magnetization current is presented.

15 June 2022 in Energies
Verified
Journal Article
Open access
PDF file
Michal KaczmarekMichal Kaczmarek
Michal Kaczmarek
ASArtur Szczęsny
Artur Szczęsny
ESErnest Stano
Ernest Stano
This paper evaluates an electronic current transformer’s wideband accuracy in the transformation of distorted current harmonics. The tests were performed in the range of frequencies from 50 Hz to 5 kHz. The utmost importance was dedicated to the transformation of the low-order higher harmonics. The novelty of this paper involves the analysis of the self-generation of the third and fifth higher harmonics caused by the nonlinearity of magnetic core magnetization characteristics. Therefore, what is considered new in this investigation is that this phenomenon has a significant influence on values of current errors and phase displacements despite the presence of the operational amplifiers and the Hall sensors in the output circuits. Another important factor to consider is the influence of the RMS value of the primary current and output load of the ECT on wideband accuracy. To show the backgrounds of the performed laboratory studies, we also discuss the operation principles of the ECTs with closed and open feedback loops. The accuracy of the tested ECT deteriorated—as with the inductive CT—by the self-generation phenomenon. This resulted in rapid changes in the values of current errors and phase displacements determined for the low-order higher harmonics.

3 June 2019 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
Michal KaczmarekMichal Kaczmarek
Michal Kaczmarek
ESErnest Stano
Ernest Stano
The increasing number of non‐linear loads and renewable energy sources causes a decrease in the power quality in the power networks. Therefore, tests of current transformers should be performed in similar conditions. This requires generation by a high current testing transformer of distorted currents that rms values are from a few hundred to several thousands of amperes with a given harmonics levels. However, its frequency band of operation is limited by inductances of its windings and connected load that result from the length and parameters of the used current track and connected device under test. To ensure the constant rms value of higher harmonic of distorted secondary current with the increase of its frequency proportional increase of the rms value of this harmonic in distorted primary voltage of the high current testing transformer is required. However, the maximum permissible value of primary voltage is limited by the dielectric strength of insulation of the primary winding. The purpose of presented studies is to determine the factors that condition the frequency band of operation of a high current testing transformer and limits the range of higher harmonics while testing of the transformation accuracy of instrument current transformers for distorted currents.