Katarzyna Tandecka

Dr. Katarzyna Tandecka

Faculty of Mechanical Engineering, Koszalin University of Technology, 75-620 Koszalin,Racławicka 15-17, Poland
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in Medical Science Monitor
Verified
Journal Article
Open access
PDF file
KGKatarzyna Grocholewicz
Katarzyna Grocholewicz
Joanna Janiszewska-OlszowskaJoanna Janiszewska-Olszowska
Joanna Janiszewska-Olszowska
TSTomasz Szatkiewicz
Tomasz Szatkiewicz
Robert TomkowskiRobert Tomkowski
Robert Tomkowski
Katarzyna TandeckaKatarzyna Tandecka
Katarzyna Tandecka
After orthodontic treatment, brackets are debonded and residual adhesive is removed, causing iatrogenic enamel damage. The aim of this study was to review the methods of orthodontic adhesive removal, find clear evidence, and provide a rationale for this procedure. A literature search was performed in PubMed, Dentistry and Oral Sciences, Scopus, Cochrane, Google, and Google Scholar using keywords: orthodontic adhesive removal, orthodontic debonding, orthodontic clean-up. Studies concerning human enamel roughness or loss from debonding and adhesive removal were considered. Forty-four full-text articles were analyzed and 3 were rejected after detailed reading; finally 41 papers were included. Fifteen qualitative studies, 13 studies based on indices of enamel surface, and 13 quantitative studies were found. No meta-analysis could be performed due to a lack of homogenous quantitative evidence. The most popular tools were tungsten carbide burs, which were faster and more effective than Sof-Lex discs, ultrasonic tools, hand instruments, rubbers, or composite burs. They remove a substantial layer of enamel and roughen its surface, but are less destructive than Arkansas stones, green stones, diamond burs, steel burs, and lasers. Multi-step Sof-Lex discs and pumice slurry are the most predictable enamel polishing tools. Arkansas stones, green stones, diamond burs, steel burs, and lasers should not be used for adhesive removal. The use of tungsten carbide bur requires multistep polishing. Further efforts should be made to find tools and methods for complete removal of adhesive remnants, minimizing enamel loss and achieving a smooth surface.

10 August 2017 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Open access
PDF file
Wojciech KacalakWojciech Kacalak
Wojciech Kacalak
Dariusz LipinskiDariusz Lipinski
Dariusz Lipinski
Błażej BałaszBłażej Bałasz
Błażej Bałasz
ŁRŁ. Rypina
Ł. Rypina
Katarzyna TandeckaKatarzyna Tandecka
Katarzyna Tandecka
FSFilip Szafraniec
Filip Szafraniec
The results of grinding are highly dependent on conditions of workpiece removal process. The material is removed by an unspecified number of abrasive grains of irregular shape and random distribution on the grinding wheel active surface. The interaction between the abrasive grain and the workpiece can be divided into three stages: (i) rubbing, (ii) ploughing and (iii) chip formation. Reciprocal contribution of each stage is dependent on the properties of the workpiece, the grinding parameters, the friction condition between the abrasive grain and the workpiece and the shape of the grains. In the article, the results of numerical and experimental process in the analysis of grinding of Ti-6Al-4V titanium alloy, using a conventional grinding wheel and a newly developed grinding wheel with aggregates of grains, were presented. The analysis of influence of the geometric parameters of the abrasive aggregates and the abrasive grains on the effectiveness of the workpiece removal process is presented. The effects of the geometrical parameters of grains and abrasive aggregates in direction of motion as well as in transversal direction on the size of ridges were determined. It has been observed that increase of the length of sideway material displacement results in the decrease of ridge formation. The results of a numerical analysis were confirmed by experimental research. The analysis of the impact of utilization of abrasive aggregates on the grinding forces, grinding-specific energy and surface roughness was performed. The impact of abrasive aggregates on the decrease of grinding forces and specific energy and the increase of quality of ground surface was observed.

30 January 2020 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
Joanna Janiszewska-OlszowskaJoanna Janiszewska-Olszowska
Joanna Janiszewska-Olszowska
ADAgnieszka Drozdzik
Agnieszka Drozdzik
Katarzyna TandeckaKatarzyna Tandecka
Katarzyna Tandecka
KGKatarzyna Grocholewicz
Katarzyna Grocholewicz
Background: Increased composite roughness enhances bacterial adhesion and discoloration, thus increasing the risk of gingival inflammation and secondary caries. Concerns about detrimental effects of sodium bicarbonate on surface roughness influenced the development of less abrasive powders: a glycine-based powder and an erythritol-based powder, additionally - sodium bicarbonate-based powder of reduced grain size. However, there is limited evidence on effects of these materials on the surface of dental fillings. The aim of the present study was to compare the effects of three air-polishing powders (of a reduced abrasiveness) on surface roughness of microhybrid restorative composite material. Material and methods: Microhybrid light-cure resin composite samples were placed on 64 plaster cubes and light-cured through polyester strips. Surface roughness was measured using laser confocal microscope (magnification 2160x). The specimens were randomly divided into three groups (n = 20, 20 and 24) and air-polished with: sodium bicarbonate (40 μm), glycine (25 μm) and erythritol (14 μm), respectively. Then surface roughness was remeasured, keeping the same field of observation. Specialized 3D analysis software was used for data processing. Parameters according to ISO 25178: Sa, Sq, Sku, Sp, Sv, Sz, Ssk were used to describe surface roughness. Results: Sa, Sq, Sp, Sv, Sz increased significantly following air polishing. Ssk was significantly higher, whereas Sku was significantly lower in sodium bicarbonate and erythritol groups than before air polishing. Comparison between the three powders revealed that Sa was significantly higher in sodium bicarbonate group than in glycine group. Sku was significantly higher in glycine and erythritol groups than in sodium bicarbonate group. Conclusions: Sodium bicarbonate has a stronger detrimental effect on composite surface than glycine or erythritol. No advantage of erythritol comparing to glycine could be found.

18 November 2015 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
Joanna Janiszewska-OlszowskaJoanna Janiszewska-Olszowska
Joanna Janiszewska-Olszowska
Katarzyna TandeckaKatarzyna Tandecka
Katarzyna Tandecka
TSTomasz Szatkiewicz
Tomasz Szatkiewicz
PSPiotr Stępień
Piotr Stępień
KSKatarzyna Sporniak-Tutak
Katarzyna Sporniak-Tutak
KGKatarzyna Grocholewicz
Katarzyna Grocholewicz
The present study aimed at 3D analysis of adhesive remnants and enamel loss following the debonding of orthodontic molar tubes and orthodontic clean-up to assess the effectiveness and safety of One-Step Finisher and Polisher and Adhesive Residue Remover in comparison to tungsten carbide bur. Thirty human molars were bonded with chemical-cure orthodontic adhesive (Unite, 3M, USA), stored 24 h in 0.9 % saline solution, debonded and cleaned using three methods (Three groups of ten): tungsten carbide bur (Dentaurum, Pforzheim, Germany), one-step finisher and polisher (One gloss, Shofu Dental, Kyoto, Japan) and Adhesive Residue Remover (Dentaurum, Pforzheim, Germany). Direct 3D scanning in blue-light technology to the nearest 2 μm was performed before etching and after adhesive removal. Adhesive remnant height and volume as well as enamel loss depth and volume were calculated. An index of effectiveness and safety was proposed and calculated for every tool; adhesive remnant volume and duplicated enamel lost volume were divided by a sum of multiplicands. Comparisons using parametric ANOVA or nonparametric ANOVA rank Kruskal-Wallis tests were used to compare between tools for adhesive remnant height and volume, enamel loss depth and volume as well as for the proposed index. No statistically significant differences in the volume (p = 0.35) or mean height (p = 0.24) of adhesive remnants were found (ANOVA rank Kruskal-Wallis test) between the groups of teeth cleaned using different tools. Mean volume of enamel loss was 2.159 mm3 for tungsten carbide bur, 1.366 mm3 for Shofu One Gloss and 0.659 mm3 for Adhesive Residue Remover - (F = 2.816, p = 0.0078). A comparison of the proposed new index between tools revealed highly statistically significant differences (p = 0.0081), supporting the best value for Adhesive Residue Remover and the worst – for tungsten carbide bur. The evaluated tools were all characterized by similar effectiveness. The most destructive tool with regards to enamel was the tungsten carbide bur, and the least was Adhesive Residue Removal.

1 December 2020 in Measurement
Verified
Journal Article
Open access
WKWojciech Kacalak
Wojciech Kacalak
DLDariusz Lipiński
Dariusz Lipiński
FSFilip Szafraniec
Filip Szafraniec
AZAnna Zawada-Tomkiewicz
Anna Zawada-Tomkiewicz
Katarzyna TandeckaKatarzyna Tandecka
Katarzyna Tandecka
Grzegorz KrolczykGrzegorz Krolczyk
Grzegorz Krolczyk

10 September 2014 in Head & Face Medicine
Verified
Journal Article
Open access
PDF file
Joanna Janiszewska-OlszowskaJoanna Janiszewska-Olszowska
Joanna Janiszewska-Olszowska
Katarzyna TandeckaKatarzyna Tandecka
Katarzyna Tandecka
TSTomasz Szatkiewicz
Tomasz Szatkiewicz
KSKatarzyna Sporniak-Tutak
Katarzyna Sporniak-Tutak
KGKatarzyna Grocholewicz
Katarzyna Grocholewicz
Presenting a new method for direct, quantitative analysis of enamel surface. Measurement of adhesive remnants and enamel loss resulting from debonding molar tubes. Buccal surfaces of fifteen extracted human molars were directly scanned with an optic blue-light 3D scanner to the nearest 2 μm. After 20 s etching molar tubes were bonded and after 24 h storing in 0.9% saline - debonded. Then 3D scanning was repeated. Superimposition and comparison were proceeded and shape alterations of the entire objects were analyzed using specialized computer software. Residual adhesive heights as well as enamel loss depths have been obtained for the entire buccal surfaces. Residual adhesive volume and enamel loss volume have been calculated for every tooth. The maximum height of adhesive remaining on enamel surface was 0.76 mm and the volume on particular teeth ranged from 0.047 mm3 to 4.16 mm3. The median adhesive remnant volume was 0.988 mm3. Mean depths of enamel loss for particular teeth ranged from 0.0076 mm to 0.0416 mm. Highest maximum depth of enamel loss was 0.207 mm. Median volume of enamel loss was 0.104 mm3 and maximum volume was 1.484 mm3. Blue-light 3D scanning is able to provide direct precise scans of the enamel surface, which can be superimposed in order to calculate shape alterations. Debonding molar tubes leaves a certain amount of adhesive remnants on the enamel, however the interface fracture pattern varies for particular teeth and areas of enamel loss are present as well.