Shaharil Mad Saad

Shaharil Mad Saad

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2015 in Sensors
Verified
Journal Article
Open access
PDF file
SSShaharil Mad Saad
Shaharil Mad Saad
AAAllan Melvin Andrew
Allan Melvin Andrew
ASAli Yeon Md Shakaff
Ali Yeon Md Shakaff
ASAbdul Rahman Mohd Saad
Abdul Rahman Mohd Saad
AKAzman Muhamad Yusof @ Kamarudin
Azman Muhamad Yusof @ Kamarudin
AZAmmar Zakaria
Ammar Zakaria
Monitoring indoor air quality (IAQ) is deemed important nowadays. A sophisticated IAQ monitoring system which could classify the source influencing the IAQ is definitely going to be very helpful to the users. Therefore, in this paper, an IAQ monitoring system has been proposed with a newly added feature which enables the system to identify the sources influencing the level of IAQ. In order to achieve this, the data collected has been trained with artificial neural network or ANN—a proven method for pattern recognition. Basically, the proposed system consists of sensor module cloud (SMC), base station and service-oriented client. The SMC contain collections of sensor modules that measure the air quality data and transmit the captured data to base station through wireless network. The IAQ monitoring system is also equipped with IAQ Index and thermal comfort index which could tell the users about the room’s conditions. The results showed that the system is able to measure the level of air quality and successfully classify the sources influencing IAQ in various environments like ambient air, chemical presence, fragrance presence, foods and beverages and human activity.

1 January 2017 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
SSShaharil Mad Saad
Shaharil Mad Saad
ASA. Y. M. Shakaff
A. Y. M. Shakaff
ASA. R. M. Saad
A. R. M. Saad
AYA. M. Yusof
A. M. Yusof
AAAllan Melvin Andrew
Allan Melvin Andrew
AAA. H. Adom
A. H. Adom
In this paper, index for indoor air quality (also known as IAQI) and thermal comfort index (TCI) have been developed. The IAQI was actually modified from previous outdoor air quality index (AQI) designed by the United States Environmental Protection Agency (US EPA). In order to measure the index, a real-time monitoring system to monitor indoor air quality level was developed. The proposed system consists of three parts: sensor module cloud, base station and service-oriented client. The sensor module cloud (SMC) contains collections of sensor modules that measures the air quality data and transmit the captured data to base station through wireless. Each sensor modules includes an integrated sensor array that can measure indoor air parameters like Carbon Dioxide, Carbon Monoxide, Ozone, Nitrogen Dioxide, Oxygen, Volatile Organic Compound and Particulate Matter. Temperature and humidity were also being measured in order to determine comfort condition in indoor environment. The result from several experiments show that the system is able to measure the air quality presented in IAQI and TCI in many indoor environment settings like air-conditioner, chemical present and cigarette smoke that may impact the air quality. It also shows that the air quality are changing dramatically, thus real-time monitoring system is essential.

19 January 2016 in Sensors
Verified
Journal Article
Open access
PDF file
AAAllan Melvin Andrew
Allan Melvin Andrew
AZAmmar Zakaria
Ammar Zakaria
SSShaharil Mad Saad
Shaharil Mad Saad
ASAli Yeon Md Shakaff
Ali Yeon Md Shakaff
In this study, an early fire detection algorithm has been proposed based on low cost array sensing system, utilising off- the shelf gas sensors, dust particles and ambient sensors such as temperature and humidity sensor. The odour or “smellprint” emanated from various fire sources and building construction materials at early stage are measured. For this purpose, odour profile data from five common fire sources and three common building construction materials were used to develop the classification model. Normalised feature extractions of the smell print data were performed before subjected to prediction classifier. These features represent the odour signals in the time domain. The obtained features undergo the proposed multi-stage feature selection technique and lastly, further reduced by Principal Component Analysis (PCA), a dimension reduction technique. The hybrid PCA-PNN based approach has been applied on different datasets from in-house developed system and the portable electronic nose unit. Experimental classification results show that the dimension reduction process performed by PCA has improved the classification accuracy and provided high reliability, regardless of ambient temperature and humidity variation, baseline sensor drift, the different gas concentration level and exposure towards different heating temperature range.

11 August 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SSShaharil Mad Saad
Shaharil Mad Saad
AAAllan Melvin Andrew
Allan Melvin Andrew
ASAli Yeon Md Shakaff
Ali Yeon Md Shakaff
MDMohd Azuwan Mat Dzahir
Mohd Azuwan Mat Dzahir
MHMohamed Hussein
Mohamed Hussein
ZAZair Asrar Ahmad
Zair Asrar Ahmad
Indoor air may be polluted by various types of pollutants which may come from cleaning products, construction activities, perfumes, cigarette smoke, water-damaged building materials and outdoor pollutants. Although these gases are usually safe for humans, they could be hazardous if their amount exceeded certain limits of exposure for human health. A sophisticated indoor air quality (IAQ) monitoring system which could classify the specific type of pollutants is very helpful. This study proposes an enhanced indoor air quality monitoring system (IAQMS) which could recognize the pollutants by utilizing supervised machine learning algorithms: multilayer perceptron (MLP), K-nearest neighbour (KNN) and linear discrimination analysis (LDA). Five sources of indoor air pollutants have been tested: ambient air, combustion activity, presence of chemicals, presence of fragrances and presence of food and beverages. The results showed that the three algorithms successfully classify the five sources of indoor air pollution (IAP) with a classification rate of up to 100 percent. An MLP classifier with a model structure of 9-3-5 has been chosen to be embedded into the IAQMS. The system has also been tested with all sources of IAP presented together. The result shows that the system is able to classify when single and two mixed sources are presented together. However, when more than two sources of IAP are presented at the same period, the system will classify the sources as ‘unknown’, because the system cannot recognize the input of the new pattern.

12 August 2017 in arXiv
Verified
Preprint
Open access
PDF file
AAAllan Melvin Andrew
Allan Melvin Andrew
AZAmmar Zakaria
Ammar Zakaria
SSShaharil Mad Saad
Shaharil Mad Saad
ASAli Yeon Md Shakaff
Ali Yeon Md Shakaff
In this study, an early fire detection algorithm has been proposed based on low cost array sensing system, utilizing gas sensors, dust particles and ambient sensors such as temperature and humidity sensor. The odor or smell-print emanated from various fire sources and building construction materials at early stage are measured. For this purpose, odor profile data from five common fire sources and three common building construction materials were used to develop the classification model. Normalized feature extractions of the smell print data were performed before subjected to prediction classifier. These features represent the odor signals in the time domain. The obtained features undergo the proposed multi-stage feature selection technique and lastly, further reduced by Principal Component Analysis (PCA), a dimension reduction technique. The hybrid PCA-PNN based approach has been applied on different datasets from in-house developed system and the portable electronic nose unit. Experimental classification results show that the dimension reduction process performed by PCA has improved the classification accuracy and provided high reliability, regardless of ambient temperature and humidity variation, baseline sensor drift, the different gas concentration level and exposure towards different heating temperature range.

1 January 2024 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
SSShaharil Mad Saad
Shaharil Mad Saad
MHMuhammad Danial Abu Hasan
Muhammad Danial Abu Hasan
ZAZair Asrar Ahmad
Zair Asrar Ahmad
MRMuhamad Izzat Aqmar Abdul Rahim
Muhamad Izzat Aqmar Abdul Rahim
The Braille system is used by blind or visually impaired persons to interact and communicate without the use of their eyes. With the tip of our fingers, we can The Braille system is used by blind or visually impaired persons to interact and communicate without the use of their eyes. With the tip of our fingers, we can