Mohamed Hussein

Mohamed Hussein

Auto-generated profile, based on publicly available information

Mohamed Hussein

Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SSShaharil Mad Saad
Shaharil Mad Saad
AAAllan Melvin Andrew
Allan Melvin Andrew
ASAli Yeon Md Shakaff
Ali Yeon Md Shakaff
MDMohd Azuwan Mat Dzahir
Mohd Azuwan Mat Dzahir
MHMohamed Hussein
Mohamed Hussein
ZAZair Asrar Ahmad
Zair Asrar Ahmad
Indoor air may be polluted by various types of pollutants which may come from cleaning products, construction activities, perfumes, cigarette smoke, water-damaged building materials and outdoor pollutants. Although these gases are usually safe for humans, they could be hazardous if their amount exceeded certain limits of exposure for human health. A sophisticated indoor air quality (IAQ) monitoring system which could classify the specific type of pollutants is very helpful. This study proposes an enhanced indoor air quality monitoring system (IAQMS) which could recognize the pollutants by utilizing supervised machine learning algorithms: multilayer perceptron (MLP), K-nearest neighbour (KNN) and linear discrimination analysis (LDA). Five sources of indoor air pollutants have been tested: ambient air, combustion activity, presence of chemicals, presence of fragrances and presence of food and beverages. The results showed that the three algorithms successfully classify the five sources of indoor air pollution (IAP) with a classification rate of up to 100 percent. An MLP classifier with a model structure of 9-3-5 has been chosen to be embedded into the IAQMS. The system has also been tested with all sources of IAP presented together. The result shows that the system is able to classify when single and two mixed sources are presented together. However, when more than two sources of IAP are presented at the same period, the system will classify the sources as ‘unknown’, because the system cannot recognize the input of the new pattern.

30 September 2024 in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
Verified
Journal Article
Open access
PDF file
NBNur’aMirah Busu
Nur’aMirah Busu
NINorasikin Mat Isa
Norasikin Mat Isa
AHAzian Hariri
Azian Hariri
MHMohamed Hussein
Mohamed Hussein
DADavid S. Adebayo
David S. Adebayo
This study explores the impact of fixed damper openings on indoor thermal comfort in a lab-scaled chamber. Experiments with maximum, medium, and minimum iris damper openings were conducted under various occupancy conditions. Results show that the maximum opening maintained temperatures close to the ideal 24°C with minimal fluctuations. In contrast, medium and minimum openings resulted in higher temperature variability and less efficient air distribution. Statistical analysis highlighted significant differences in temperature stability among the different damper settings. The maximum opening ensured a stable temperature range, while the minimum opening caused noticeable temperature stratification and discomfort, especially with more occupants. The findings indicate that fixed damper openings are inadequate for maintaining consistent thermal comfort due to their lack of adaptability. This underscores the need for advanced control systems that can dynamically adjust damper positions to ensure optimal indoor temperature regulation and improve energy efficiency.

15 March 2025 in Semarak Engineering Journal
Verified
Journal Article
Open access
PDF file
SYSiti Nur Mariani Mohd Yunos
Siti Nur Mariani Mohd Yunos
NINorasikin Mat Isa
Norasikin Mat Isa
NNNormayati Nordin
Normayati Nordin
MMMuhamad Farooq Musa
Muhamad Farooq Musa
MHMohamed X Mohamed Hussein
Mohamed X Mohamed Hussein
WSWinardi Sani
Winardi Sani
Coal and natural gas are used to generate almost 93% of electricity in Peninsular Malaysia. While the use of coal in the energy industry increases, the impact of coal burning on the environment should be emphasized. Incomplete combustion in boilers frequently results in a substantial amount of unburned carbon in the ash and pollutant emissions. A key factor in resolving this issue is to improve classification quality by achieving a higher particle separation quality in which at least 70% of the coal particles leaving the classifier are smaller than 75μm. The effect of the flow inside the coal pulveriser with varying vane angles (45° and 60°) on classification in coal-fired power plants was investigated using three-dimensional (3-D) computational fluid dynamics modelling. The realisable k-ε turbulence model (RKE) with a detailed 3-D coal pulveriser geometry was used to solve the flow inside the coal mill, while the discrete phase model was used to solve the coal particle flow. The coal mill with a vane angle of 60° resulted in better escaped particles with 69.35% of the coal particles with 50-micron size escaped and 59.68% of coal particles with 75-micron size escaped from the outlet. The flow pattern inside the coal mill for the 60° vane angle model is also fine which is swirling from the bottom of the tank.

28 September 2022 in Journal of Advanced Research in Technology and Innovation Management
Verified
Journal Article
Open access
PDF file
NBNur’aMirah Busu
Nur’aMirah Busu
NINorasikin Mat Isa
Norasikin Mat Isa
AHAzian Hariri
Azian Hariri
MHMohamed Hussein
Mohamed Hussein
Thermal comfort, influenced by temperature distribution, plays a crucial role in maintaining occupants' well-being and productivity within indoor environments. Most of the building with centralized air conditioning system is accommodated with inlet diffuser with fixed opening area of inlet air damper. This paper present the justification that the indoor temperature distribution is struggling to be maintained at ideal temperature when using fixed inlet air damper. Experimental study has been conducted using iris damper pattern with three opening type and 4 occupancy conditions. Results shows that when there is no occupant, the indoor temperature will keeps decreasing below 24°C. Meanwhile, with the increment of occupancy, the indoor temperature keeps increasing and able to reach up to 27°C. This condition will leads to thermal discomfort among occupants. Thus, a step-based control method is reliable to be implemented in manipulating the opening area of iris damper to maintain the indoor temperature at the ideal temperature.