▪ Abstract Interrogation of tissue with light offers the potential for noninvasive chemical measurement, and penetration with near-infrared wavelengths (750–1000 nm) is greater than with visible light. Specific absorption by clinically relevant compounds such as oxy- and deoxyhemoglobin and the intracellular respiratory enzyme cytochrome oxidase enable in vivo measurement of these to be performed safely and conveniently. This is the basis of in vivo near-infrared spectroscopy (ivNIRS). Multiple scattering of the interrogating beam by tissues leads to an optical path that is considerably longer than the simple physical pathlength and this complicates the analysis. Modeling of photon propagation through tissues with, for example, finite element and Monte Carlo methods, is assisting in improving the ivNIRS methodology. Instrumentation has advanced from simple continuous wave approaches, through time-resolved methods based on either time-domain or frequency-domain approaches, to spatially resolved measurement based on diffuse reflectance. Initial clinical applications were for monitoring the brain in the neonate and fetus and muscle in adults. Currently, use in adults and children for neurological assessments are of growing interest.
Prolonged periods of driving in monotonous situations may lower a driver's activation state as well as increasing their stress level due to the compulsion to maintain safe driving, which may result in an increased risk of a traffic accident. There is therefore an opportunity for technological assessment of driver physiological status to be applied in-car, hopefully reducing the incidence of potentially dangerous situations. As part of our long-term aim to develop such a system, we describe here the investigation of differential skin temperature measurement as a possible marker of a driver's stress level. 10 healthy male subjects were studied, under environment-controlled conditions, whilst being subjected to simulated monotonous travel at constant speed on a test-course. We acquired measurements of relevant physiological variables, including truncal and peripheral skin temperatures (Ts), beat-by-beat blood pressure (BP), cardiac output (CO), total peripheral resistance (TPR), and normalized pulse volume (NPV) used as an indicator of local peripheral vascular tone. We then investigated the driver's reactivity in terms of cardiovascular haemodynamics and skin temperatures. We found that the simulated monotonous driving produced a gradual drop in peripheral Ts following the driving stress, which, through interpretation of the TPR and NPV recordings, could be explained by peripheral sympathetic activation. On the other hand, the truncal Ts was not influenced by the stress. These findings lead us to suggest that truncal-peripheral differential Ts might be used as a possible index indicative of the driver's stress. Such an index, if decisively validated, would be easy to apply in real driving situations by using radiation thermometer.
We describe further development of a novel method for non-invasive measurement of blood glucose concentration (BGL), named Pulse Glucometry, based on differential near infrared spectrophotometry. Sequential temporal differences of infrared transmittance spectra from the radiation intensity (Ilambda) emerging from a fingertip containing an arterial pulse component (DeltaIlambda) are analysed. To perform the measurements we developed a new high-speed spectrophotometer, covering the wavelength range from 900 to 1700 nm, scanning at a maximum spectral rate of 1800 spectra/s, with a minimum exposure time of 20 mus. Spectra related only to the pulsatile blood component are derived, thus minimising influences of basal components such as resting blood volume, skin, muscle and bone. We have now improved the performance of the spectrophotometer and in the present paper we describe new in vivo measurements carried out in 23 healthy volunteers undergoing glucose tolerance tests. Blood samples were collected from the cephalic vein simultaneously with radiation intensity measurements in the fingertip every 10 min before and after oral administration of glucose solution for 120 min. BGL values were then predicted using a PLS calibration model and compared with blood values determined by colorimetric assay. The precision and accuracy of the non-invasive determinations are encouraging.
Frequent fish consumption is related to a lower risk of coronary heart disease. However, the physiological mechanisms underlying this cardioprotective effect are as yet unknown. We therefore examined certain cardiovascular physiological variables of fish eaters during rest, whilst conducting mental arithmetic, and during recovery.
The purpose of this study was to investigate the cardiovascular hemodynamic effects of Red Bull® Energy Drink during prolonged, simulated, monotonous driving. This was a double-blind, within-subjects-design, crossover study. Twelve healthy volunteers (21.7 ± 0.8 years old) experienced each of three conditions at various times: 1) consumption of Red Bull® Energy Drink; 2) consumption of placebo-controlled drink; and 3) no test drink. All subjects undertook 90-min periods of simulated monotonous driving, during which physiological measurements were made. The variables recorded were cardiovascular indices, i.e., mean blood pressure (MBP), cardiac output (CO), electrocardiogram RR interval (RR), total peripheral-vascular resistance (TPR: = MBP/CO), and normalized pulse volume (NPV). Additional parameters were the standard deviation of lateral position, i.e., the weaving of the car, and subjective rating of sleepiness. CO, RR, and TPR during the monotonous task were significantly different in those consuming the energy drink as compared with those receiving the placebo and as compared with no drink values. The energy drink elicited a cardiac-dominant reaction pattern, while the other conditions demonstrated the vascular-dominant reaction pattern typically observed in monotonous driving tasks. The observed differences indicate the cardiovascular system being more aroused with the energy drink. The effects of Red Bull® Energy Drink were reflected in cardiovascular hemodynamic phenomena especially to the heart function, and we conclude that consumption of this drink before long-distance driving in non-sleepy drivers could facilitate more physiologically active, and possibly safer, driving.
1 August 2010 in Optoelectronics, Instrumentation and Data Processing
This review concerns the design and use of micro- and nanosensors based on electrochemical, acoustic, piezoelectric, and optical principles for medical diagnosis and care and for biological research. The target measurands include an ever-increasing number of simple and complex molecules, physical quantities, and electrical and magnetic phenomena.