The aim of this paper is to investigate the water pressure effects on hydraulic fracture behavior of concrete with wedge-splitting testing under dynamic loading. Five waterproof strain gauges are stuck along the crack path to observe the fracture process during the experiments. Four silicon water pressure sensors successfully measured the water pressure value on concrete face. The results show that the water pressure on crack faces accelerates the crack propagation of the concrete. The critical values of the splitting force decrease 26.7 and 25.6%, respectively, with the external applied water pressure of 0.2 and 0.4 MPa. Moreover, the hydraulic crack propagation speed increases at the beginning and tends to reach a peak value finally. The peak value of cracking speed is 11.08 m/s, which is high. Under dynamic loading, the water fails to fill the crack and only the trapped water interacts with the crack face. The water pressure is mainly a parabolic curve distribution along the crack path and the peak value decreases with the increase in the crack length.
In non-design conditions, severe hydraulic instability can affect the stability of a pump station and even shorten its service life. A Francis pump station in the South-to-North Water Transfer Project was examined to carry out a numerical simulation of the entire flow passage using a bidirectional fluid–solid method for static and fatigue life. Due to the inlet setting, reverse power generation exhibited a more distorted flow pattern that resulted in higher energy loss than the pump condition. The radial force acting on the blades in reverse power generation was 39.1% higher. Runner stress was mainly concentrated at the leading edge and blade edge. The maximum stress in reverse power generation was 35.7 MPa, which was about 28.5% higher than in the pump condition. While the maximum deformation was 0.035 mm, almost 94.4% more severe than in the pump condition, mainly concentrated at the leading edge. Based on the fatigue analysis, a minimum safety factor obtained numerically was 8.238 in the pump condition and 6.343 in the reverse power condition, respectively. The safety factors satisfy the safety standard of the runner material and meet requirements of safety and stability in the reverse power generation condition.
The application of blasting in modern engineering construction is prized for its speed, efficiency, and cost-effectiveness. However, the resultant vibrations can have significant adverse effects on surrounding buildings and residents. The challenge of optimizing blasting procedures to satisfy excavation needs while minimizing vibration impacts is a critical concern in blasting excavation. This research addresses this challenge through the development of a 3D simulation and analysis model for an underground pumped storage power plant in East China, utilizing the LS-DYNA finite element analysis software. To explore the influence of charging structures on rock fragmentation and vibration propagation, three distinct blasting programs were formulated, each featuring varied configurations within the machinery room. The analysis revealed that the adoption of an optimized charging structure can significantly decrease damage to the protective layer by approximately 40%, while also reducing the impact on the upstream and downstream side walls by 27.25% and 12.03%, respectively, without compromising the efficacy of the main blast zone. Moreover, the vibration velocities at the remote measurement point were found to be reduced across multiple directions, indicating effective control of the vibration effects. The post-implementation of the optimized blasting strategy at the site, the assessment of the retained surrounding rock integrity, and the impact on protected structures demonstrated that the proposed solution met satisfactory outcomes. This study underscores the potential of simulation-based optimization in managing vibration risks during blasting operations, offering a valuable tool for engineers and practitioners in the field of underground construction.
In the field of marine resource development, conventional axial-flow adjustable-blade pumps rely on the monolithic rotation of rigid blades for operational condition regulation, a mechanism constrained by simplistic angular adjustments that inadequately adapt to the dynamic and complex marine operational environment. To address this limitation, this study proposes a novel angle-adjustment scheme utilizing flexible variable-twist blades, where operational condition regulation is achieved through active blade twisting, enabling refined and adaptive angle modulation. Four typical blade profiles were selected for the variable-twist blades at distinct angular positions (−1°, +1°, −2°, and +2°), corresponding to the four conventional angle-adjustment positions of axial-flow adjustable-blade pumps. Numerical simulations were conducted to investigate the hydraulic performance impacts of the proposed flexible variable-twist blades compared to traditional rigid blades under identical angular configurations. The results demonstrate that under high-flow conditions (1.2 Q), the torsion-based angle-adjustment strategy exhibits superior efficiency across all four angular positions: −1° configuration: 11.1% efficiency improvement; +1° configuration: comparable efficiency; −2° configuration: 78% efficiency improvement; and +2° configuration: 3.2% efficiency improvement. Moreover, at equivalent angular settings, the variable-twist blades significantly enhance hydraulic performance and expand the high-efficiency operating range of the pump compared to conventional rigid blades. The implementation of flexible variable-twist blade technology not only advances the performance of axial-flow pumps in marine engineering applications but also provides a new approach for high-efficiency research on axial-flow pumps.